Please read this manual carefully to ensure correct use of the product. Keep the manual handy after reading for future reference. This document for the CL-H601A Scanner Head Unit describes installation, maintenance and system specifications. For instructions for welding control using the SWDraw3 application, refer to the manual for SWDraw3.
1 Scanner Head Unit ..................... 21 2 Dimension of the Mounting Hole ................ 24 Chapter 7 Inspection and Parts Replacement ........25 1 Before Inspection and Parts Replacement............25 2 Parts Replacement..................... 25 3 Protective Glass Inspection and Replacement........... 26 CL-H601A...
Indicates that incorrect operation may result in injury to personnel or damage to property. CAUTION Indicates prohibited actions and warns of actions not covered by the product warranty. Indicates actions that must be performed by users. The triangular symbol indicates details that supplement DANGER, WARNING, or CAUTION points. CL-H601A...
Page 6
(light-absorbing/scattering body capable of withstanding high temperatures) to prevent laser emission beyond the stopper. Wear protective work clothing. Wear protective clothing such as gloves, long-sleeved clothing, and a leather apron. Spatter will cause burn injuries if it lands on the skin. CL-H601A...
Page 7
There is a risk of damage to the cable and electric shock or fire if the cable is pulled to unplug. Do not cover with blankets or sheets. Do not cover the system with blankets or sheets while in use. Otherwise there is a risk of over-heating and fire. CL-H601A...
During this time, do not turn off the power switch of the laser control unit. (11) If a computer is connected, never disconnect the LAN cable before turning off the power switch of the laser control unit. CL-H601A...
Page 9
MPE: The maximum level of permissible exposure of the eyes or skin to laser beams. Abbreviation of Maximum Permissible Exposure. * For other information on managing laser equipment or the MPE level, refer to the following standards. IEC Standards IEC60825-1 “Safety of laser products Part1: Equipment Classifications, requirements and use’s guide” [Warning/Caution label details] CL-H601A...
By combining the optional camera unit with the PC application SWDraw3 attached to our laser control unit CL-E100A, scanning can be used more conveniently. By combining the collimator and the fθ lens, various spot diameters can be realized. CL-H601A...
Overall Configuration Optical fiber Camera connecting cable LAN cable Computer Camera unit Laser equipment connecting cable Scanner connecting Laser control unit Laser equipment cable Power cable for Scanner head unit control unit Power cable for scanner Scanner power supply unit CL-H601A...
The main unit of the scanner (SUPERSCAN IV manufactured by RAYLASE GmbH). (9) Mounting plate For dimensions of the mounting hole, see "Chapter 6-2. Dimension of the Mounting Hole" (page 24) . (10) Water-cooled tube connector Not used. (11) fθ lens CL-H601A...
Page 13
2. Name and Functions of Each Section (12) Handle Carry the Head Unit by holding this handle. Do not hold the collimator unit. The positional relationship between coordinate axes XY and the center of lens is as shown below. CAUTION CL-H601A...
Verify that contents of the container agree with the following list. The components marked with * are built in the scanner head unit. Component Quantity Scanner head unit Label (LB1173123) Label (LB1191496) Operation manual fθ lens * Collimator lens unit * Camera unit * CL-H601A...
Installation 2.1. Installation Requirements Refer to the following figure when installing the scanner head unit. Scanning may produce dust and others, we recommend installing a dust collector. The required clearance changes depending on the direction of the collimator unit. CL-H601A...
Page 16
(6) When using two opposing scanner head units, install them so that the laser of neither head is aimed at the other head. A laser directed at parts within the other scanner head unit may burn the unit interior. CL-H601A...
Page 17
(4) In case of the camera unit attached, a camera and peripheral components are coming with it. A camera and peripheral components have been assembled. Since the angle and the focal point have been already adjusted, do not remove or move them carelessly. CL-H601A...
Power supply voltage Average: Approx. 2 A, Maximum: Approx. 5 A Current consumption 233(W) mm × 480(D) mm × 375(H) mm (when using fθ lens: f306 External dimensions and collimator: f150) Approx. 12 kg (excluding fθ lens and collimator) Mass CL-H601A...
2. Lens Unit Lineup Lens Unit Lineup 2.1. Fθ Lens f (mm) Work distance (mm) Machining area (mm) f306 373.6±5 □150 2.2. Collimator Lens f (mm) f100 f120 f150 Depending on the laser equipment you use, some collimator lenses are not available. CL-H601A...
Page 20
Monochrome Magnification: x1.5 Image adjusting unit ( 1.5) Cable for USB3.0 camera 5 m, black • Block diagram * This connector is not used. USB3.0 cable Monochrome USB camera Corresponding MF-C series Connect to either. Corresponding laser control unit CL-H601A...
Page 21
5 m, blue, CAT7 USB LAN conversion adapter USB3.0, 19 cm-long • Block diagram * This connector is not used. PoE/DATA DATA PoE-supported LAN cable Monochrome GigE camera PoE injector Corresponding MF-C series Connect to either. Corresponding laser control unit CL-H601A...
Page 22
Size: 10.1 inch, 15.6 inch BNC cable Length: 5 m, 10 m Video converter Converts SDI signal to HDMI. • Block diagram * +12 V drive: Be careful of incorrect connection. HDMI cable BNC cable (cable for SDI signal) Video converter Monitor CL-H601A...
1. Scanner Head Unit Chapter 6 Outline Drawing Scanner Head Unit For dimensions of the mounting hole of the mounting plate, see "Chapter 6-2. Dimension of the Mounting Hole" (page 24) . 1.1. f306 Collimator lens f100 f120 f150 CL-H601A...
Page 24
1. Scanner Head Unit 1.1.1. Vertical-type collimator unit Dimensions in mm The length may be up to +60 mm depending on the selected camera. Pay attention to peripheral design in assembly. CL-H601A...
Page 25
1. Scanner Head Unit 1.1.2. Horizontal-type collimator unit Dimensions in mm The length may be up to +60 mm depending on the selected camera. Pay attention to peripheral design in assembly. CL-H601A...
As user-serviceable parts wear with use, performance will decline, eventually requiring repairs or replacement. Inspect the unit regularly, referring to the guidelines provided in the following table: Item No. Component Model No. Schedule Maintenance (Recommended) f306 PO1160337 1160337 fθ lens 5 years Replace CL-H601A...
Wipe the protective glass as shown, in a spiraling motion from the center out. If the ethanol fails to clean the protective glass, replace the protective glass with a new one. Wipe in a spiraling motion CL-H601A...
Page 29
The protective glass may be damaged if it is not properly fitted into the stepped section. • CAUTION Depending on the protective glass, be careful of its orientation. Protective glass sectional view ○ × Reattach the protective glass holder to the scanner head unit. CL-H601A...
Need help?
Do you have a question about the CL-H601A and is the answer not in the manual?
Questions and answers