SELECT FAN SETTING (AUTO / ON / CIRCULATE)
When the fan mode is changed during a program
event, it remains in that mode until the next event
starts The fan must be programmed to Fan On
in the schedule to run continuously through all
events
1. Press SELECT to enter Main Menu
2. Use
or
to select the Fan option
3. Press SELECT to enter Fan menu:
4. Use
or
to select the desired fan mode
On: Fan runs continuously Use this mode for
maximum air circulation/filtering.
Auto: Fan runs only when the heating or cooling
system is on
Circulate: Same as Auto, but ensures the fan
is on for at least 30 minutes per hour Use this
mode for a balance of energy savings and air
circulation/cleaning
5. Press SELECT to save the fan mode and return to
the home screen, or BACK to exit without saving
10
1
3
Main Menu
Mode
Fan
Hold
Schedule
Heat Blast
5
Fan
On
4
4
Auto
Circulate
MAINTENANCE REMINDERS
Maintenance reminders are set up by the installer to indicate when the equipment is due for
service. If a maintenance reminder is displayed, call your HVAC dealer for service. They can be
3
reset by selecting the Reset option on the reminder message or in the Reset Service Reminders
option found in the Settings menu
2
LOCKOUT
The user can disable access to the thermostat's features (See USER SYSTEM SETTINGS TABLE on
page 30 for details) This feature can be overridden by pressing and holding the SELECT button
for 7 seconds
11