Compact hydraulic power pack type INKA 1 Assembly instructions Oil immersed compact hydraulic power pack with built-in electric motor (AC or 3-phase version) and single-circuit pump. For short period operation S2 and periodic intermittent operation S3. (Translation of the original instructions) B 8132-1 02-2023 ...
Page 2
HAWE Hydraulik respects these legal provisions in all cases. HAWE Hydraulik cannot provide individual guarantees that the stated circuits or procedures (including in part) are not subject to the intellectual property rights of third parties.
Checking and replacing the pressure and return line lters..................33 7.2.5 Checking the valves............................34 7.2.6 Checking accumulator systems........................... 34 7.2.7 Checking the motor............................34 7.2.8 Replacing an external fan..........................35 Disassembly and disposal..........................37 Troubleshooting..............................38 HAWE Hydraulik SE B 8132-1 - 02-2023 - 1.3 en 3/55...
Page 4
Current consumption characteristic lines......................48 10.1.8 Additional options............................49 10.1.8.1 Additional option: sensor system........................49 10.1.8.2 External fan..............................49 10.1.9 Sensor characteristics............................49 10.2 Documents...............................51 10.2.1 Declaration of incorporation..........................51 10.2.2 Declaration of conformity..........................53 4/55 B 8132-1 - 02-2023 - 1.3 en HAWE Hydraulik SE...
The manual provides relevant information for the machine manufacturer and machine operator as well as for training courses. You can request further information on the product at: HAWE Hydraulik SE, Einsteinring 17, 85609 Aschheim/Munich, Germany. 1.2 Safety instructions and symbols...
Page 6
Wear safety goggles to protect your eyes against chemical and mechanical hazards. Protective clothing Wear tted clothing without protruding parts. Follow the safety data sheet of the hydraulic uid. 6/55 B 8132-1 - 02-2023 - 1.3 en HAWE Hydraulik SE...
1.3 Applicable documents Documents D 5488/1 Oil recommendations D 8132-1 Data sheet for compact hydraulic power pack type INKA 1 B 5488 General operating manual for the assembly, initial operation and maintenance of hydraulic components and systems Declaration of incorporation "Declaration of incorporation (EU)"...
Only use the product for the stipulated purposes. Use in other operating modes than specied in the intended use ■ Using the product beyond the specied performance limits ■ 8/55 B 8132-1 - 02-2023 - 1.3 en HAWE Hydraulik SE...
The operating company must ensure the operating conditions (see the technical data) are within the limits for use of the product. Keep all instructions/signs on the product in legible condition and observe them. HAWE Hydraulik SE B 8132-1 - 02-2023 - 1.3 en 9/55...
In the instructions, safety instructions with mandatory symbols indicate the wearing of special protective equipment for special activities. The supply of PPE, and instruction in its proper use, is carried out by the operator. 10/55 B 8132-1 - 02-2023 - 1.3 en HAWE Hydraulik SE...
The external fan is mounted on the side on the intermediate ange. External fan (optional) External fan start can be programmed for an oil temperature between 40°C and 70°C (any 10°C increment selectable). Programmed switching hysteresis is 10°C. HAWE Hydraulik SE B 8132-1 - 02-2023 - 1.3 en 11/55...
■ Function Sensors with IO-Link Sensors with switch output ✓ IO-Link ✓ 3 switch outputs ✓ ✓ Visualisation ✓ ✓ External fan control ✓ Parametrisation interface Parametrisation via IO-Link 12/55 B 8132-1 - 02-2023 - 1.3 en HAWE Hydraulik SE...
1 s, a speed at least 10% above idle speed (which is at least 1650 rpm in 4-pole motors), the parametrised power frequency is automatically raised to 60 Hz. Automatic parametrisation will not occur in the reverse direction. HAWE Hydraulik SE B 8132-1 - 02-2023 - 1.3 en 13/55...
The measured speed and the geometric pump output volume congured ex-works are used to continuous- Theoretical ow rate ly calculate the (theoretical) ow rate. This value is equivalent to the ow rate under ideal conditions, i.e. without taking into account internal leaking etc. 14/55 B 8132-1 - 02-2023 - 1.3 en HAWE Hydraulik SE...
Page 15
LEDs are off, the external fan is running and the switch outputs are at GND potential. If the rmware is invalid (e.g. because the update was interrupted), the sensors remain in this operating mode. HAWE Hydraulik SE B 8132-1 - 02-2023 - 1.3 en 15/55...
■ Cable tting M20x1.5 for version with communication box or M16x1.5 for connecting motor in ■ communication box (not required for version with HARTING plug [P1-P3]) Hydraulic uid ■ 16/55 B 8132-1 - 02-2023 - 1.3 en HAWE Hydraulik SE...
Document transport damage with photos and report to the manufacturer. 3. Properly dispose of the product packaging in accordance with local regulations. NOTICE For any defect found, le a complaint immediately with: HAWE Hydraulik SE Einsteinring 17 85609 Aschheim near Munich, Germany Tel.: +49 89 379100-1491 service@hawe.de...
Property damage from incorrectly installed hydraulic system Assembly by trained specialists only. Ensure all labels and markings of the hydraulic system are easily visible and legible after assembly. Check installation space/connection points for damage. 18/55 B 8132-1 - 02-2023 - 1.3 en HAWE Hydraulik SE...
Page 19
7. Connecting hydraulic lines: To connection block or valve section ■ Or to your own connection block ■ 8. After a week of operating time at the latest, check the ttings. HAWE Hydraulik SE B 8132-1 - 02-2023 - 1.3 en 19/55...
2. Filter fresh hydraulic uid. Recommended lter: 10 μm, see "Technical data", page 40 3. Pour the ltered hydraulic uid into the tank. 4. Close the tank opening with the breather lter. 20/55 B 8132-1 - 02-2023 - 1.3 en HAWE Hydraulik SE...
Route control cables and power cables separately. Leave a 10 to 20 cm gap between the control cables and power cables. Provide separate shields for analogue and digital control lines. HAWE Hydraulik SE B 8132-1 - 02-2023 - 1.3 en 21/55...
The product type can optionally connect the motor to the communication box (order coding in to communication box 8132-1D 8132-1). (Coding P0) Remove communication box’s cover 3-phase power Alternating current U1/Z2 U1/W2 V1/U2 W1/V2 22/55 B 8132-1 - 02-2023 - 1.3 en HAWE Hydraulik SE...
The unit is secured against being switched on unintentionally. Motor is connected. Check external fan’s wiring to communication box. Plug connector (Coding P1 The unit is secured against being switched on unintentionally. to P3) Motor is connected. HAWE Hydraulik SE B 8132-1 - 02-2023 - 1.3 en 23/55...
✓ Scope of information is equivalent to IO-Link variant. 5. Remove the programming cable. 6. Place the communication box’s cover back in position and tighten the screws to a torque of 1 + 0.3 Nm. 24/55 B 8132-1 - 02-2023 - 1.3 en HAWE Hydraulik SE...
Sensors with switch output (coding E2): Position X2, permitted cable length 20 m (M12 for ■ interface’s switch output) NOTICE When not using the plug, protect it with an IP67-rated protective cover. HAWE Hydraulik SE B 8132-1 - 02-2023 - 1.3 en 25/55...
3. Wire the operating capacitor to the machine controls in accordance with the circuit diagram. 4. Connect the hydraulic power pack to the electrical power supply. 5. Check the electrical connections after a week’s operating time. 26/55 B 8132-1 - 02-2023 - 1.3 en HAWE Hydraulik SE...
3. Electrical: Wiring, power supply, control Set motor protection circuit 1. The electric motor must be protected with a motor protection circuit, see Chapter 5.3.1, "Connecting the motor", page 22 HAWE Hydraulik SE B 8132-1 - 02-2023 - 1.3 en 27/55...
Page 28
The operating states of the external fan, LEDs and switch outputs (optional) match their parametri- ■ sation. Check LEDs’ status ■ Compare switch outputs’ status with expected values ■ 28/55 B 8132-1 - 02-2023 - 1.3 en HAWE Hydraulik SE...
The hydraulic system is switched on and off via the system controller. Initial start-up of the system must have been performed properly. When using with an external fan, it must be ensured that fresh air can be aspirated and that the hot air can be vented. HAWE Hydraulik SE B 8132-1 - 02-2023 - 1.3 en 29/55...
NOTICE Disconnecting electrical power sources Plug connection on compact hydraulic power pack (various types of plug optionally available) or Power supply unit in overall machinery (see owner’s operating instructions) 30/55 B 8132-1 - 02-2023 - 1.3 en HAWE Hydraulik SE...
– Insert the other end into the tank ller opening (unscrew the breather lter). ✓ When the hydraulic uid ow is free of bubbles, the pump has been bled. HAWE Hydraulik SE B 8132-1 - 02-2023 - 1.3 en 31/55...
10 to 20 to 40 to 60 to 70 to 80 to > 98% 20 % 40 % 60 % 80 % 80 % 98 % measured LED 6 LED 5 LED 4 32/55 B 8132-1 - 02-2023 - 1.3 en HAWE Hydraulik SE...
2. If external leakages are found, shut down and repair the system. Replacing The hydraulic system is switched off and secured against unintentional restart. The system is pressureless. The work environment is clean. HAWE Hydraulik SE B 8132-1 - 02-2023 - 1.3 en 33/55...
Checking and lling NOTICE Refer to the following additionally applicable documents concerning checking and lling of accumulator systems: D 7969 D 7571 7.2.7 Checking the motor Once a year. Maintenance interval 34/55 B 8132-1 - 02-2023 - 1.3 en HAWE Hydraulik SE...
Electrical and electronic components must only be replaced and connected by trained specialist personnel. Obey all applicable electrical safety rules. Only connect electric lines to the hydraulic system while the system is de-energized. HAWE Hydraulik SE B 8132-1 - 02-2023 - 1.3 en 35/55...
Page 36
3. Undo the ange connection between tank and external fan. 4. New external fan: Connect mechanically. Wire to communication box or connect using the plug connector. 5. Connect the electric power supply. 36/55 B 8132-1 - 02-2023 - 1.3 en HAWE Hydraulik SE...
uid according to the regional waste disposal requirements. Dispose of the electronic components at approved collection points or with approved disposal companies according to local regulations. Dispose of metal with approved specialist disposal companies. HAWE Hydraulik SE B 8132-1 - 02-2023 - 1.3 en 37/55...
6156 [0x180C] Warning Temperature unknown – the temperature cannot be measured or the measured value is potential- ly invalid (e.g. if the uid level is too low) 38/55 B 8132-1 - 02-2023 - 1.3 en HAWE Hydraulik SE...
Page 39
35904 [0x8C40] Info Cleaning message 35905 [0x8C41] Info Rell message 35906 [0x8C42] Info Replacement message 36350 [0x8DFE] Error Test parameter event A 36351 [0x8DFF] Error Test parameter event B HAWE Hydraulik SE B 8132-1 - 02-2023 - 1.3 en 39/55...
+70°C. Start temperature: down to -40 °C is permissible (take account of the start viscosities!), as long as the steady-state temperature is at least 20 K higher during subsequent operation. 40/55 B 8132-1 - 02-2023 - 1.3 en HAWE Hydraulik SE...
Tank Tank size + 0 kg + 0.3 kg + 0.7 kg Motor 3 ~ 0.25 kW + 0.3 kg 3 ~ 0.55 kW + 2.2 kg 1 ~ 0.37 kW + 1.2 kg HAWE Hydraulik SE B 8132-1 - 02-2023 - 1.3 en 41/55...
0.65 2.10 1.05 2.05 0.85 2.75 1.65 2.60 1.10 NOTICE Tank size 1 only available with 3-phase motor 0.25 kW 10.1.5 Characteristic lines 10.1.5.1 Build-up of heat 0.25 kW 42/55 B 8132-1 - 02-2023 - 1.3 en HAWE Hydraulik SE...
Page 43
); ST steady-state excess temperature (K) Duty cycle = Relative duty cycle 0.37 kW hydraulic work value (bar cm ); ST steady-state excess temperature (K) Duty cycle = Relative duty cycle 0.55 kW HAWE Hydraulik SE B 8132-1 - 02-2023 - 1.3 en 43/55...
Measured in acoustic measurement chamber acc. to DIN EN ISO 3744, distance sound sensor to pump (d) Running noise H pump = 1 m 0.25 kW hydraulic work value(bar cm ); noise level dB(A) 0.37 kW hydraulic work value(bar cm ); noise level dB(A) 44/55 B 8132-1 - 02-2023 - 1.3 en HAWE Hydraulik SE...
Operating voltage: 3x 575 V AC ■ Frequency: 10 to 400 Hz ■ max. motor power: 7.5 kW ■ Capacitor Capacitor is not included in the scope of delivery HAWE Hydraulik SE B 8132-1 - 02-2023 - 1.3 en 45/55...
Page 46
46/55 B 8132-1 - 02-2023 - 1.3 en HAWE Hydraulik SE...
); I current consumption (A) 0.37 kW hydraulic work value (bar cm ); I current consumption (A) 0.55 kW hydraulic work value (bar cm ); I current consumption (A) 48/55 B 8132-1 - 02-2023 - 1.3 en HAWE Hydraulik SE...
VDE, CSA, UL, CE VDE, CSA, UL, CE VDE, CSA, UL, CE 10.1.9 Sensor characteristics Designation Power Unit Sensor Speed measuring range 120 to 5000 rpm Fluid level measurement ±5% accuracy HAWE Hydraulik SE B 8132-1 - 02-2023 - 1.3 en 49/55...
Page 50
-15 to 15 V (PELV electrical circuit recommended) Activation/visualisation 1000 ms delay At ambient temperatures above 50°C, the total current for the external fan and switch outputs must not exceed 3000 mA. 50/55 B 8132-1 - 02-2023 - 1.3 en HAWE Hydraulik SE...
10.2.2 Declaration of conformity HAWE Hydraulik SE B 8132-1 - 02-2023 - 1.3 en 53/55...
Page 54
54/55 B 8132-1 - 02-2023 - 1.3 en HAWE Hydraulik SE...
Page 55
Further information HAWE Hydraulik SE is a responsible development partner with application expertise and experience in more than 70 areas of mechanical and plant engineering. The product range includes hydraulic power packs, constant and variable pumps, valves, sensors and accessories.
Need help?
Do you have a question about the INKA 1 and is the answer not in the manual?