Hide thumbs Also See for Primor 2000:

Advertisement

Quick Links

User's manual
Primor 2000 / Level 5
Content
1 General instructions __________________________________________________________ 2
1.1 Liability notes _________________________________________________________________ 2
1.2 Operating notes _______________________________________________________________ 2
1.3 Notes on safety ________________________________________________________________ 2
2 Visual and acoustic signals____________________________________________________ 2
3 Input unit _____________________________________________________________________ 3
4 Operating the lock ____________________________________________________________ 3
4.1 Opening _____________________________________________________________________ 3
4.2 Locking ______________________________________________________________________ 3
5 Programming the lock ________________________________________________________ 4
5.1 Master and user code __________________________________________________________ 4
5.1.1 Programming the user code (programme 1) _____________________________________ 4
5.1.3 Deleting the user (programme 3) _______________________________________________ 4
5.2 Time delay and opening window_________________________________________________ 5
5.2.3 Deleting the time delay (programme 9) _________________________________________ 6
6 Testing the system (programme 5) ____________________________________________ 7
7 Power supply and battery change _____________________________________________ 7
© Carl Wittkopp GmbH - Errors and omissions excepted
User´s manual no. 9999-114-1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Primor 2000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Wittkopp Primor 2000

  • Page 1 5.2.2 Opening with activated time delay and opening window __________________________ 6 5.2.3 Deleting the time delay (programme 9) _________________________________________ 6 6 Testing the system (programme 5) ____________________________________________ 7 7 Power supply and battery change _____________________________________________ 7 © Carl Wittkopp GmbH - Errors and omissions excepted User´s manual no. 9999-114-1...
  • Page 2 Primor 2000 / Level 5 1 General instructions • Please read the operating instructions carefully, before activating the lock. 1.1 Liability notes • We don’t assume liability for malfunctions due to incorrect operation, use of force or inappropriate handling. In cases of damage to property or valuables, which are due to incorrect locking of the safe, we also don’t assume liability.
  • Page 3 Primor 2000 / Level 5 3 Input unit Primor RO 4 Operating the lock 4.1 Opening   123456 1. Enter the 6-digit code e.g. master code. Turn the input unit clockwise within 3 seconds into opening position. The lock is opened.
  • Page 4 Primor 2000 / Level 5 5 Programming the lock 5.1 Master and user code 5.1.1 Programming the user code (programme 1)   The master is able to program the user code, but not vice versa. 1. Press and hold the key “1“ until the red LED flashes permanently.
  • Page 5 Primor 2000 / Level 5 5.2 Time delay and opening window Only the master can program or delete the time delay. Time delay: 01 - 99 minutes - time to wait until the lock can be opened. Opening window: 01 - 19 minutes - within this time window the master or the user can open the lock with his code.
  • Page 6 Primor 2000 / Level 5 5.2.2 Opening with activated time delay and opening window   123456 1. Enter your 6-digit code e.g. mastercode. ☼ 2. Wait until the end of the time delay. ☼ 3. Opening window starts. 123456 4.
  • Page 7 Primor 2000 / Level 5 6 Testing the system (programme 5) Press every number once. A functional key will be confirmed by a double signal. A key that was not identi-   fied is confirmed by a long signal and the functional test is aborted. The system has to be checked.
  • Page 8 Primor 2000 / Level 5 04.05.2012...

Table of Contents