Advertisement

User's manual
Content
1 General instructions __________________________________________________2
1.1 Liability notes _________________________________________________________2
1.2 Operating notes _______________________________________________________2
1.3 Notes on safety ________________________________________________________2
2 Visual and acoustic signals____________________________________________3
3 Input units ____________________________________________________________3
4 Operating the lock ____________________________________________________3
4.1 Opening _____________________________________________________________3
4.1.1 Opening with alarmcode (silent alarm) _________________________________4
4.2 Locking ______________________________________________________________4
5 Programming the lock ________________________________________________5
5.1 Master and user codes _________________________________________________5
5.1.1 Programming a user code _____________________________________________5
5.1.2 Changing the master or user code _____________________________________5
5.1.3 Deleting a user ______________________________________________________5
5.2 Time delay and opening window_________________________________________6
5.2.3 Deleting the time delay _______________________________________________7
5.2.4 Opening with the instant opening code _________________________________8
6 Operation blocking ___________________________________________________8
7 Overview users _______________________________________________________8
8 Testing the system ____________________________________________________9
9 Power supply and battery change _____________________________________9
© Carl Wittkopp GmbH - Errors and omissions excepted
Rel. 1.6
01.02.2016
Bedienungsanleitung Nr. 9999-116-1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Primor 2000 / Level 15 and is the answer not in the manual?

Questions and answers

Summary of Contents for Wittkopp Primor 2000 / Level 15

  • Page 1: Table Of Contents

    5.2.4 Opening with the instant opening code _________________________________8 6 Operation blocking ___________________________________________________8 7 Overview users _______________________________________________________8 8 Testing the system ____________________________________________________9 9 Power supply and battery change _____________________________________9 © Carl Wittkopp GmbH - Errors and omissions excepted Rel. 1.6 01.02.2016 Bedienungsanleitung Nr. 9999-116-1...
  • Page 2: General Instructions

    Primor 2000 / Level 15 1 General instructions • Please read the operating instructions carefully, before activating the lock. 1.1 Liability notes • We don’t assume liability for malfunctions due to incorrect operation, use of force or inappropriate handling. In cases of damage to property or valuables, which are due to incorrect locking of the safe, we also don’t assume liability.
  • Page 3: Visual And Acoustic Signals

    Primor 2000 / Level 15 2 Visual and acoustic signals Signal Explanation Comment  Right code  Wrong code or code denied Short signal Long signal LED flashes every 10 seconds Blocking time is active. ☼ LED flashes every 2 seconds Time delay is active.
  • Page 4: Opening With Alarmcode (Silent Alarm)

    Primor 2000 / Level 15 4.1.1 Opening with alarmcode (silent alarm) Alarmcode: the number to be added to the last number of the code. Usually this is 1. If the result becomes double-digit only the last number is taken (e.g. 9+1=10, enter only 0).
  • Page 5: Programming The Lock

    Primor 2000 / Level 15 5 Programming the lock 5.1 Master and user codes 5.1.1 Programming a user code (programme 1)   The master is able to program a user code, but not vice versa. 1. Press and hold the key “1“ until the red LED flashes permanently.
  • Page 6: Time Delay And Opening Window

    Primor 2000 / Level 15 5.2 Time delay and opening window Only the master can program or delete the time delay. Time delay: 01 - 99 minutes - time to wait until the lock can be opened. Opening window: 01 - 19 minutes - within this time window the master or the user can open the lock with his code.
  • Page 7: Opening With Activated Time Delay And Opening Window

    Primor 2000 / Level 15 5.2.2 Opening with activated time delay and opening window   1234567 1. Enter your 7-digit code e.g. mastercode. ☼ 2. Wait until the end of the time delay. ☼ 3. Opening window starts. 1234567 4.
  • Page 8: Opening With The Instant Opening Code

    Primor 2000 / Level 15 5.2.4 Opening with the instant opening code The instant opening code is meant to bypass the time delay. The instant opening code is assigned to user 9. A corresponding user code has to be activated.
  • Page 9: Testing The System

    Primor 2000 / Level 15 8 Testing the system (programme 5) Press every number once. A functional key will be confirmed by a double signal. A key that was not identi-   fied is confirmed by a long signal and the functional test is aborted. The system has to be checked.
  • Page 10 Primor 2000 / Level 15...

Table of Contents