14 Technical data
14.1 Piping diagram: Outdoor unit
7.0 CuT
7.0 CuT
7.0 CuT
7.0 CuT
7.0 CuT
7.0 CuT
Y1S
S1PH
k
9.5 CuT
ERGA04~08DAV3(A) + EHBH/X04+08DA*V7
Daikin Altherma 3 R W
4P618958-1 – 2020.03
A subset of the latest technical data is available on the regional Daikin website
(publicly accessible). The full set of latest technical data is available on the Daikin
Business Portal (authentication required).
h
R2T
4.0 CuT
4.0 CuT
4.0 CuT
M1F
12.7 CuT
12.7 CuT
R3T
12.7 CuT
j
i
M1C
a Field piping (liquid: Ø6.4 mm flare connection)
b Field piping (gas: Ø15.9 mm flare connection)
c Stop valve (liquid)
d Stop valve with service port (gas)
e Filter
f Muffler with filter
g Capillary tube
h Heat exchanger
i Accumulator
j Compressor accumulator
k Muffler
M1C Compressor
M1F Fan
R1T Thermistor (outdoor air)
R2T Thermistor (heat exchanger)
R3T Thermistor (compressor discharge)
S1PH High pressure switch (automatic reset)
Y1E Electronic expansion valve
Y1S Solenoid valve (4‑way valve)(ON: cooling)
Heating
Cooling
R1T
g
g
6.4 CuT
6.4 CuT
g
f
Y1E
e
k
6.4 CuT
15.9 CuT
d
14
Technical data
|
c
a
6.4 CuT
b
15.9 CuT
3D110394
Installer reference guide
211