GAS REQUIREMENTS

To verify the fuel type (either propane or natural gas) the fire feature is designed to use, refer to the label on the bottom
of the control box.
Natural Gas (NG) Requirements
Ensure that the service supplying the fire feature is fitted
with a positioned shut off valve that is easily accessible.
Always check the rating plate to make sure the gas
supply you are connecting to is the gas intended for your
fire feature. The installation of this appliance to a fixed
piping system must conform with local codes or, in the
absence of local codes, to the National Fuel Gas Code,
ANSI 2223.1, NFPA 54; National Fuel Gas Code; Natural
Gas and Propane Installation Code, CSA 8149.1 as
applicable.
Natural gas connection must be performed by a licensed
contractor or local gas company representative.
Supply Pressure
Minimum: 6.3" W.C.
Normal: 7.0" W.C.
Maximum: 7.7" W.C. (1/2 psi)
Pressure Testings
If the fire feature is installed with a fixed fuel piping
system and equipped with an appliance gas pressure
regulator, the fire feature and its individual shut-off
valve must be disconnected from the gas supply piping
system during any pressure testing of the system at test
pressure in excess of 1/2 psi (3.5 kPa).
The fire feature must be isolated from the gas supply
piping system by closing its individual manual shut off
valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than 1/2
psi (3.5 kPa).
Refer to the table below and Natural Gas (NG) Pipe
Sizing, page 8 for natural gas line requirements.
1/2ʺ
NG
LP
10'
80'
1 BOWL
[3.1 m]
[24.4 m]
20'
2 BOWLS
-
[6.1 m]
10'
3 BOWLS
-
[3.1 m]
4 BOWLS
-
-
5 BOWLS
-
-
6 BOWLS
-
-
NG = Natural Gas / LP = Liquid Propane
2" - 3" WC maximum pressure drop
MAGICFLAME™ Fire and Water Bowl Installation and User' s Guide
3/4ʺ
NG
LP
NG
50'
300'
175'
[15.2 m]
[91.4 m]
[53.3 m]
[137.2 m]
10'
80'
40'
[3.1 m]
[24.4 m]
[12.2 m]
30'
20'
-
[9.1 m]
[6.1 m]
20'
10'
-
[6.1 m]
[3.1 m]
10'
-
-
[3.1 m]
10'
-
-
[3.1 m]
Propane Gas (LP) Requirements
RISK OF EXPLOSION IF UNIT IS INSTALLED
NEAR PROPANE GAS STORAGE! Locate the
fire bowl away from propane gas storage and filling equipment as
specified by the Standard for the Storage and Handling of Liquefied
Petroleum Gases, CAN/CSA B149.2 (latest edition) or ANSI/NFPA 58
(latest edition).
A propane tank is not included with the fire feature and
will need to be provided.
Always check the rating plate to make sure the gas
supply you are connecting to is the gas intended for your
fire feature. The installation of this appliance to a fixed
piping system must conform with local codes or, in the
absence of local codes, to the National Fuel Gas Code,
ANSI 2223.1, NFPA 54; National Fuel Gas Code; Natural
Gas and Propane Installation Code, CSA 8149.1, or
Propane Storage and Handling Code, CSA 8146.2 as
applicable.
Manifold Pressure
For plumbed-in Propane Gas installation, use a properly
sized regulator according to supply pressure.
Supply Pressure
Minimum: 9.9" W.C.
Normal: 11.0" W.C.
Maximum: 12.1" W.C. (½ psi)
Refer to the table below and Liquid Propane (LP)
Gas Pipe Sizing, page 8 for propane gas line
requirements.
SIZE OF PIPE (IN.)
1-1/4ʺ
LP
NG
LP
450'
400'
-
[121.9 m]
250'
200'
-
[76.2 m]
[61 m]
125'
70'
450'
[38.1 m]
[21.3 m]
[137.2 m]
60'
50'
250'
[18.3 m]
[15.2 m]
[76.2 m]
40'
30'
150'
[12.2 m]
[9.1 m]
[45.7 m]
30'
20'
125'
[9.1 m]
[6.1 m]
[38.1 m]
1-1/2ʺ
NG
LP
NG
-
-
-
400'
-
-
[121.9 m]
200'
450'
-
[61 m]
[137.2 m]
125'
500'
400'
[38.1 m]
[152.4 m]
[121.9 m]
70'
400'
200'
[21.3 m]
[121.9 m]
[61 m]
50'
250'
175'
[15.2 m]
[76.2 m]
[53.3 m]
LP
-
-
-
-
-
-