  • Page 3 DEAR CUSTOMER THANK YOU FOR CHOOSING A GLOBUS PRODUCT. WE REMAIN AT YOUR DISPOSAL FOR ANY ASSISTANCE OR ADVICE YOU MAY NEED DOMINO s.r.l. via Vittorio Veneto 52 31013 - Codognè - TV - Italy Tel. (+39) 0438.7933 Fax. (+39) 0438.793363 e-mail:info@globusitalia.com...
  • Page 4: Table Of Contents

    Table of contents TECHNICAL FEATURES........................6 Device ............................... 6 Storage and transport conditions ....................6 Use conditions ..........................6 Magnetic intensity that can be emitted with flexible diffusers ..........6 Power supply ............................ 6 EQUIPMENT ............................6 Accessories description ........................7 Magnum Test ............................
  • Page 5 Disposal of the device ........................19 INSTRUCTIONS FOR USE ........................20 EASY PROGRAM ..........................20 EDITING THE PARAMETERS QUICKLY ON EASY PROGRAM ............20 SAVING A PROGRAM QUICKLY FROM THE PROGRAM LIST TO EASY PROGRAM ....21 START PROGRAM ..........................22 “LAST 10”...
  • Page 6: Technical Features

    TECHNICAL FEATURES Device Size: 100x160x35 mm Weight: 296 g Protection level: IP 20 + IP 02 Storage and transport conditions The storage and transportation of the device and its accessories, in their original packag- ing, are subject to the following limits: Storage and transportation temperature: From -25°C to 70°C Max.
  • Page 7: Accessories Description

    SOLENOIDS G3216 MAGNUM XL 1 flexible solenoid G4279 MAGNUM XL (SOFT SOL.) 2 single SOFT solenoids Accessories description Magnum devices can be used with some optional accessories. Magnum Test The Magnum Test is used to check that the solenoids work properly. Connect the solenoid to the device, start a program, put the box upon a coil and check that a vibration is felt.
  • Page 8 G5988 Pocket Pro Solenoid Solenoid consisting of two coils inserted in a soft pad and stored inside a zip-up case that is easily washable and sanitized (see chapter on maintenance and cleaning). Dimensions 15,5x9,5 cm G4276 Soft mat 4 Soft and comfortable two-channel mat, made up of 4 total spires, whose material is easy to clean and sanitizable.
  • Page 9: Intended Use

    Mats G5944 100 Memory Foam Mat: the new Globus mat with a double layer of Memory Foam and 4 solenoids inside. It's particularly suited for long treatments during which the user, though remaining in contact with the mat, is free to move without being tied to the device through the traditional solenoids.
  • Page 10: Instructions For The Use Of The Water-Proof Case

    - physiotherapy centers; - rehabilitation in general; - pain treatments in general; - for aesthetic and sport purposes; The use of this equipment is allowed to the patient (appropriately informed of the condi- tions of use of the apparatus) and the medical staff. CE0476 does not refer to non-medical treatments.
  • Page 11: Connections

    CONNECTIONS Device Magnum XL operates connected to the mains. To connect the power supply to the con- nector, plug it as shown below. Warning: If the case, the cable or the connector of the power supply show signs of wear or damage, replace the product instantly.
  • Page 12: Labelling And Symbols

    LABELLING AND SYMBOLS It refers to the manufacturer Warning: the applied parts can reach temperatures that may cause redness or burns. Keep the device dry This symbol on your device indicates that it complies with the requirements of the directives on medical devices (93/42/EEC 47/2007EEC).
  • Page 13: Device

    The image is just for indication. For technical data see the first chapter. Input PWR: GTM41060-2512 IP20 PRI: 100-240Vac 50-60Hz Max 0,6A SEC: 12Vdc 2,08A Output Freq.: 5 – 200Hz Output Power: 140 Gauss Magneto: MAGNUM XL *MJ0431700001* SN: MJ0431700001 Rev 3 – 12.11.2020...
  • Page 14: Dashboard And Keyboard

    DASHBOARD AND KEYBOARD ON/OFF/OK Button It confirms the selection. While a program is running, it ac- tivates the pause. 3” = On/Off. Back/left button Moves the selection to the left. To go back to the previous selection. If pressed for 3'' while the program is running, it returns to the previous selection.
  • Page 15: Display/Interface

    Display/Interface Program Type of power name FRACTURES supply Solenoid 1 Solenoid 2 Indicators GAUSS TIME   Duration Power in Gauss ALARMS Compliance Certifications: CE MDD certificate Acoustic signals comply with directive 60601-1-8. Open circuit The device is equipped with a power-emission control system. Before starting any treatment, it is therefore necessary to ensure that the diffuser is connected to the device and placed on the area to be treated.
  • Page 16: Warnings And Contraindications

    Do not use Magnum XL combined with other electronic devices, especially if they main- tain vital functions. Read the tables at the end of the present handbook for a correct use of Magnum XL. If the device is used nearby or on other devices, make sure it works properly.
  • Page 17: Warnings During The Use

    Warnings during the use The device is intended for continuous functioning. While using Magnum XL, please comply with the following indications: - in the case of damaged cables, they must be replaced with original parts and not used anymore; - the device must be kept out of the reach of any pet that could damage it and con- taminate it with parasites;...
  • Page 18: Maintenance And Cleaning

    - do not use in the case of tuberculosis. MAINTENANCE AND CLEANING Maintenance and cleaning of the device - In case of real or alleged malfunctioning, do not tamper with the device and do not try to repair it by yourself. Do not intervene on the device and do not open it. Only special- ized and authorized centers can repair it.
  • Page 19: Cleaning The Flexible Solenoids

    Cleaning the flexible solenoids - To clean these solenoids, use a clean cloth moistened with Amuchina or quaternary ammonium salts diluted in distilled water in a percentage equal to 0.2 - 0.3%. Allow the accessory to dry completely before using it again. - Alternatively, sanitize the solenoid with steam appliances (steam gun, steam iron…).
  • Page 20: Instructions For Use

    Turn on/off To turn on or off, press and hold OK until the acoustic signal is heard. Homepage Use P+ and P- to make the selection and press OK to confirm your choice. Magnum XL Easy Program Program List Advanced EASY PROGRAM This function allows to start a magnetotherapy treatment in few simple clicks.
  • Page 21: Saving A Program Quickly From The Program List To Easy Program

    Easy Program GAUSS FREQ TEMPO G  Hz  m  The new parameters will remain in memory even when the machine is turned off or the page is quit by pressing the back button. This allows an easy setting of the parameters indicated, for example, by the physician. Af- ter the first setup, every time the device is turned on, the treatment can start in two clicks.
  • Page 22: Start Program

    PROGRAM LIST Use P+ and P- to select the program and press OK to confirm your choice. TURNING ON EASY PROGRAM ADVANCED PROGRAM LIST SELECT PROGRAM START Press OK to start the program Overwrite the program saved SAVE TO EASY PROGRAM in “Easy Program”...
  • Page 23 How to pause/stop the program To pause the program, press OK. Press OK again to go back to the program execution. During the pause, pause icons appear on the screen. To stop the program in advance, hold down OK until you hear a continuous beep. Display peak Gauss While the device is operating, it is possible to display the maximum intensity of the field by pressing *.
  • Page 24: Last 10" Menu

     System info “LAST 10” MENU Magnum XL stores the last ten programs executed. This way, these are available for a quick and very easy execution. The programs are automatically stored at the end of the execution. If the memory is full, the "oldest"...
  • Page 25 “PROGRAMMING” MENU Magnum XL offers the possibility of creating/editing new programs. This allows the device to be flexible and adaptable to your needs. From the "Programming" menu you can create new programs (when the message "EMP- TY"...
  • Page 26 Setting the parameters After performing these steps, a screen will appear to modify the four necessary parame- ters as needed: field (Gauss), frequency (Hz), time and duty cycle (in %). After entering all parameters, press the OK button and confirm the saving. Programing New program name FREQ...
  • Page 27 How to save a treatment Once you have chosen the program you want to run you can select "Save for rental". Set the number of sessions to be programmed using P + and P-, then press the OK button. This way the program has been saved and can be found in the rental menu. Execute a treatment stored in rental Once you have selected the rental menu you will see a screen like this: Rental...
  • Page 28: Setup" Menu

    By choosing the option “Save for rental” you will be asked to enter the number of sched- uled sessions. The program will be stored in the treatment area along with changes (except for fre- quency and duty cycle, which remain as in the default program). “SETUP”...
  • Page 29: Action Principle And Application Method

    Direction of the current SOUTH The treatment parameters The Globus devices for magnetotherapy emit low frequency signals of rectangular form (up to 200 HZ). The frequency is the number of pulses per second. The intensity of the Rev 3 – 12.11.2020...
  • Page 30 magnetic field is measured in Gauss (G), while the Duty Cycle is the pulsed time (since we're talking about pulsed electromagnetic fields). When the duty cycle is at 100% we talk about continuous emission, if it is less than 100% we say pulsed emission. In our devices, the duty cycle is set to 50%, but it can be edited to lower levels.
  • Page 31: General Application Methods

    Let’s see at a glance what are the benefits of magnetotherapy on the musculoskeletal apparatus: - enhances osteogenesis stimulating osteoblast activity, accelerating the osseous callus formation and mobilizing calcium ions; - reduces the inflammations; - improves the flow of the capillaries and microcirculation; - promotes the reabsorption of edemas and interstitial fluids;...
  • Page 32 POCKET PRO SOLENOIDS Fig. C Fig. D Figure C shows the Pocket Pro solenoid containing two coils. In figure D the same has been schematized to understand the orientation of the coil contained within it. The polari- ty is oriented as follows: the side with the writing S indicates south of the solenoid while the side with the writing N indicates north.
  • Page 33 ONE-COIL SOFT SOLENOIDS NORD Fig. H Fig. I One-coil soft solenoid is shown in figure H, the same solenoid has been shown schemati- cally in figure I in order to understand the orientation of the coil contained inside. The po- larity is oriented as follows: the South corresponds to the smooth part of the solenoid, the North to the part where the buttonhole is.
  • Page 34: Indications About The Programs

    where it is necessary to act in depth. In order to obtain a concatenated magnetic field it is necessary to pay attention to the correct positioning of the solenoids which have to be oriented with the same polarity. The flexible solenoids contain two coils with the polarity already inserted so as to be easily opposed.
  • Page 35 case we suggest to increase the recommended power by 50-60% since the thickness of the plaster cast increases the distance between the solenoids and the bone. We remind you of the importance of the positioning of the solenoids in an opposed way (if possible according to the area to be treated) and in correspondence of the fracture.
  • Page 36 Post knee surgery: these are specific programs to be used after surgery for reconstruction of the anterior cruciate (Post LCA) or after a cleaning operation of the cartilage. In these cases, the use of pulsed magnetic fields, from the first days after surgery, reduces pain, swelling and inflammation allowing a faster recovery.
  • Page 37: Program List

    PROGRAM LIST Program list HEALTH – REHAB (medical treatments) In accordance with the last regulations of the Ministry of Health, medical treatments are presented in the list below. Treatment Name Recommended Recommended duration Power Fractures 30 Gauss 8h a day Rotator Cuff Tendinitis 30 Gauss 30’, 3-4 times a week...
  • Page 38: Warranty Conditions

    Program List AESTHETICS - FITNESS (non-medical treatments) X = Program available in the device Treatment Name Recommended Power Recommended duration Drainage 40 Gauss 30’ Cellulitis 30-50 Gauss 45’ Edematous States 40-60 Gauss 30’ Swollen Legs 50 Gauss 30’ Reactivating Treatment 50 Gauss 30’...
  • Page 39 NOTE: Before returning the device for repairs, we suggest reading carefully the user man- ual and consulting the Globus website. If you have to return the product for repair, please contact your dealer or the Globus cus- tomer service. SOLENOIDS...
  • Page 40 Connect the power supply and hold the "ok" button for 4 seconds. Why can't I set the gauss? To create a successful communication between the solenoids and the central unit, the device must be turned on after connecting the solenoids to the input channels and then you can set the gauss.
  • Page 41 EMC accompanying documents Essential performance PERFORMANCE CONDITION RISK ACCEPTED EVENT Magnetic field  Disturbance outside the  Display information no  The machine must stop the emission. emission. electronic circuit. longer readable.     The machine must maintain the  emission and accept the commands. Lack of internal power  Interruption of the  The machine must signal the battery  supply in the absence of  treatment. exhaustion and the interruption of  external power supply. the treatment. Lack of internal power  Interruption of the  In the presence of external power  supply in the presence of  treatment. supply the machine must operate  external power supply. thanks to that source of energy and  it has to recharge the battery as a  source of internal energy. Lack of external power  Interruption of the  The machine, if equipped with a ...
  • Page 42 Rev 3 – 12.11.2020...
  • Page 43 Rev 3 – 12.11.2020...
  • Page 44 Rev 3 – 12.11.2020...

Table of Contents