Page 3
DEAR CUSTOMER THANK YOU FOR CHOOSING A GLOBUS PRODUCT. WE REMAIN AT YOUR ENTIRE DISPOSAL FOR ANY ASSISTENCE OR ADVICE YOU MAY NEED Genesy 3000 The electrostimulators GL3K (Genesy 3000) are manufactured and distributed DOMINO s.r.l. via Vittorio Veneto 52 31013 - Codognè...
Table of contents TECHNICAL FEATURES .......................... 7 Device ............................... 7 Technical features of the currents EMS and TENS: ..............7 EQUIPMENT ............................9 INTENDED USE ............................. 10 CONNECTIONS ........................... 11 Battery: how to charge the batteries..................11 How to connect the cables ......................11 Electrode application ........................
Page 6
“Program List” menu ........................23 “Last 10” menu ..........................25 “Favorites” menu ........................... 26 “Treatments” menu........................26 “Programming” menu ........................27 “Advanced” menu ........................28 ACTION PRINCIPLES ........................... 32 Muscular electrostimulation ........................32 Tens ................................ 35 Microcurrents ............................36 ...
TECHNICAL FEATURES Device Size: 220x170x60 mm Weight: 790 gr. Case: in Food Grade ABS Protection level: IP 20 Storage and transportation temperature: from -10°C to 45°C Max. relative humidity: 30% - 75% The values indicate the limits allowed if the product or its accessories are not in the original package.
Page 8
Min. intensity: 0 µA/1000 Ohm Step 10 µA Max. Intensity: 800 µA/1000 Ohm Amplitude value: included between 1 and 250 µseconds Interferential: Channels available: Channels 1-3 Max. intensity: 60 mA Main frequency: 2500 Hz - 4000 Hz - 10000 Hz Frequency modulation: 0 - 200 Hz Pulse modulation:...
EQUIPMENT B- C The electrostimulator is supplied complete of cables and electrodes to use: therefore, opening the package, it is necessary to check that the basic equipment is complete. If some elements should be missing, contact immediately the authorized retailer where you purchased the product. 4 colored electrode connection cables (for EMS, TENS, DENERVATED, INTERFERENTIAL, RUSSIAN treatments) and 2 gray cables for electrode connection (for MICROCURRENT and IONOFORESIS treatments)
The duration of the battery is 6 months, we suggest replacing it after that period. The Genesy 3000 devices are not designed to be used at home and are intended to be used in the following operating environments: - clinics;...
Device Power supply by electricity grid. Genesy 3000 can operate also connected to the mains 115-230 V. To connect the power supply to the connector, plug it as shown below (see how to charge the batteries).
NOTE: for EMS and TENS currents use indifferently the 4 channels with colored cables. NOTE: for microcurrent programs use only channels 1 and 3 with gray cables. NOTE: for denervated muscles programs (rectangular, triangular, trapezoidal) use only channles 1 and 3 with gray cables. NOTE: for interferential programs use only the channels 1 and 3 with colored cables.
LABELLING AND SYMBOLS Warning This symbol on your device indicates that it complies with the directives on medical devices (93/42/CEE 47/2007CEE). The number of the notified unit is 0476 It indicates that this is a II class device It indicates that this device has type BF parts WEEE symbol (Waste of Electrical and Electronic Equipment).
Polythene symbol Device Input PWR: GlobTek Model: GTM91099-6024-6.0-T2 PRI: 100-240V~ 50-60Hz 1.5A SEC: 18 V = 3.33A Input Power: 18Vdc 1.65A Output: 120mApk (1000Ω) Nerve and Muscle stimulator: GENESY 3000 SN: E3KR201700001 Internal Battery: 12V 2000mAh Ni-MH REV.01 del 06.12.2017...
Page 15
Accessories Electrodes It indicates the dimensions of the electrode It indicates the number of electrodes contained in the package It indicates the product code It refers to product certification and indicates that it complies with directive 2001/95/EC updated as 2014/357/EU It indicates the storage temperature of the electrodes Clean and degrease the skin.
Do not leave the electrodes in the car. All the provided information can be modified without previous notice. PANEL AND KEYBOARD Increase/Decrease intensity button button Function button P+ button Right/User button Left/Back button ON/OFF/OK button P- button NOTE : When the 3” message appears, it means that pressing the button for 3 seconds the function is activated.
* Button To start and stop the contraction during the execution of the “Action Now” programs (in the devices that have these functions). fn (Runtime) Pressed together with other buttons, it modifies their function, while pressed alone during the stimulation, it permits to access to the Runtime function (to modify time, frequency and amplitude).
ALARMS Compliance Certifications: CE MDD certificate. The sound and acoustic signals are in compliance with directive 60601-1-8. Meaning of the “Electrode error” alarm If one or more cables are not connected to the mains, or if microcurrents cables are used to an EMS program, on the display the following alarm will appear: "Electrode error"...
- Be sure that the cables and the electrodes are clean before each application. - In case of damaged cables, they must be replaced with original parts and no longer used. - Use only Globus branded electrodes. - Pay particular attention when the current density for every electrode is above 2mA/cm2 (effective value).
- Patients suffering of a total/subtotal prolapse of the uterus/vagina should be stimulated with extreme care. - Patients with infections to the urinary passages should be treated for these symptoms before starting the stimulation treatment. - Before removing or touching the probe it is necessary to turn off the stimulator or to regulate the intensity of both the channels on 0,0 mA.
- Do not intervene on the device and do not open it. Only specialized and authorized centers can repair it. - Avoid violent impacts that may cause damage and malfunctions to the device even if undetectable immediately. - Use this device in a dry environment and in an open space (not wrapped in any materials).
Accessories Use and storage of the electrodes and the cables. In case of wear of cables or electrodes, they must be replaced and no longer used. Before applying the electrodes on the skin, we suggest cleaning it. After using the multi-purpose single patient and/or single-use electrodes, they must be stored using their plastic film and placed in the plastic bag.
Last 10 Program List Favorites Treatments Programming Advanced “Program List” menu When selecting “Program List”, the following areas, according to the model, are shown: - SPORT - FITNESS-PHYSICAL SHAPE - BEAUTY-AESTETHICS - MEDICAL CURRENTS MICROCURRENTS DENERVATED IONOPHORESIS ...
Page 24
Add to Treatments (see “Treatments” menu); Continue with 2+2 (see 2+2 mode). To start the program, confirm with Start and in the following screen increase the channel intensity. Increase/decrease intensity To increase/decrease the intensity of the single channel, press the Up and Down buttons of the correspondent channels.
How to skip a phase In order to pass to a next phase before the end of the one in progress, press and hold the RIGHT button for 3 seconds. To return to the previous phase, press the left (back) button for 3 seconds. “Last 10”...
Placing the cursor on "Electrode placement ", a brief guide for correct electrode placement is displayed. For further information on the electrode placement, see the picture included in the end of this manual. c. Placing the cursor on "Delete from the list", the selected program will be no longer present in the "Last 10 executed programs"...
If the problem persists, contact the customer service. “Programming” menu The Electrostimulator offers the possibility to create/ modify new programs. This makes the device highly flexible and adaptable to all users' requirements. From the "Programming" menu it is possible to create new programs (when the message EMPTY appears) and to execute already personalized programs.
“Advanced” menu The advanced menu is composed of the following entries: Mode 2+2 User selection Working time Setup Diagnostics Turn off Mode 2+2 The device permits to execute two different programs (Ems or Tens) at the same time, permitting the simultaneously treatment of two patients or two muscular groups.
Page 29
User Selection It permits to use the special menus ("Last 10", "Favorites") in a personalized manner. To access to the favorite programs and to “Last 10” programs, the user should select his/her own user. Only that specific user can use the programs stored in the “Favorites”...
Page 30
Diagnostics The device proposes a complete protocol to find the best parameters to stimulate a denervated muscle. The parameters can easily defined and stored. Program name insertion Use the LEFT and RIGHT buttons to select letters and confirm with OK. To delete a letter, move the cursor on “Delete”.
Page 31
The device selects automatically a value of intensity equal to the double quantity of the reobase. The amplitude of the impulse is set up automatically to the minimal value. The operator must gradually increase the value of the amplitude of the impulse.
Chronaxy included between 1 and 10 milliseconds: this moderate increase of the chronaxy reveals a weak denervation rate that does not necessarily demand a preventive treatment, considering the limited number of denervated fibres. Chronaxy included between 10 and 20 milliseconds: an evident increase in the chronaxy and the presence of spontaneous activity reveal that a certain number of motor unities is inhibited while others are working.
Page 33
The same type of mechanism is activated when the muscular contraction is produced by the EMS; they have the same function of a pulse naturally transmitted by the motor nervous system. When the contraction is over, the muscle relaxes and returns to its original state.
Page 34
of contraction because of the accommodation phenomena. The current intensities recommended in the different phases are proposed as indicative values, and each person should modify these levels according to his/her personal needs. - Moderate intensity. The muscle does not tire, not even during prolonged treatments.
Open circuit The device has a check of power emissions. If the operator increases the intensity level above 10 mA and the circuit is open (cables are not connected to the device and electrodes are not applied to the skin), the electrostimulator brings immediately the intensity to 0 mA.
chemical block of the pain signals occurs. The endorphins are opioids naturally produced by the body to tackle the pain and they can act both on the marrow and on the brain, in this way they are effective analgesics. Tens can increase the natural production of endorphins and, thereby, they act decreasing the pain perception.
Denervated The stimulation of a denervated muscle differs from the one of a healthy muscle for the fact that the activation of muscular fibres needs of particular currents. In presence of a traumatic lesion of the peripheral nerves, the measure of the chronaxy fosters to establish if the denervation is insufficient, partial or total.
Trapezoidal current Trapezoidal impulses are mainly used on partially denervated muscles. The program varies according to the amplitude of the impulse and the duration of the rest. Interferential current The interferential current is a sinusoidal current alternated to medium frequencies (2500 Hz, 4000 Hz, or 10000 Hz), modulated in amplitude, characterized by a high ability to penetrate tissues and by an optimal tolerability, even in particularly sensitive patients.
PROGRAM LIST Sport Program List Demo Capillarization Warm-up Pre-competition warm-up Active recovery Maximum strength Endurance strength Explosive strength Aerobic endurance Reactivity Post-competition recovery Decontracting Hypertrophy TOTAL 53 Some programs may have more levels. CE0476 does not refer to non-medical treatments. Fitness-Physical Shape Program List Firming Bio-Pulse firming...
Page 40
Beauthy-Aestethics Program List Drainage Lipolysis Toning massage Skin tone improvement Connective massage Post-pregnancy drainage Post-pregnancy lipolysis Post-pregnancy firming TOTAL 16 CE0476 does not refer to non-medical treatments. Medical currents – Microcurrents Program List The following programs are medical Tendon inflammation Knee osteoarthritis Acute pain Epicondylitis...
Page 41
NOTES ON THE USE OF MICROCURRENT PROGRAMS This paragraph refers to the use of microcurrent programs. The microcurrent programs differ from normal TENS and EMS programs as follows: - While conventional electrostimulation (e.g. TENS) uses current in the milliamperes range, microcurrent electrostimulation uses currents in the microampere range that are imperceptible by humans.
Page 42
Medical currents – Denervated Program list The following programs are medical Triangular 1 Triangular 2 Triangular 3 Trapezoidal 1 Trapezoidal 2 Trapezoidal 3 Rectangular 1 Rectangular 2 Rectangular 3 TOTAL 9 The denervation level and the program to use are identified by the doctor using an electromyograph.
Page 43
water, to promote conductivity. - To run the Ionophoresis programs, use exclusively one special gray cable connected to the outlet of channel 1. Either the light gray or dark gray cable may be used. - The Ionophoresis programs cannot be run in the "2+2 mode" with multiple treatments.
Page 44
Medical currents-Pain Antalgic (Tens) Program List The following programs are medical Endorphinic Tens Muscle injuries Sciatica Cervical pain Epicondylitis Carpal tunnel Hip osteoarthritis High frequency antalgic Tens Nerve compression Muscle pain Chronic pain Post-surgery pain Scapulohumeral syndrome Low frequency antalgic Tens Spinal osteoarthritis Spinal osteoporosis Ankle osteoarthritis...
Page 45
Medical currents-Rehabilitation Program List The following programs are medical Swollen ankles Atrophy Hemiplegia-upper limbs Hemiplegia-lower limbs Recovery after ACL surgery Functional recovery Ankle re-education Leg re-education Muscle spasms Shoulder subluxation Vastus medialis reinforcement Total 11 Because of the presence of clinical programs, this product is a medical device. Therefore it is certified by the KIWA CERMET ITALIA S.P.A.
Page 46
Type The urology programs require the use of specific endovaginal and endorectal electrode probes, certified according to the Directive for Medical Devices 93/42/EEC. These are bipolar probes with a 2-mm female adapter which attaches to 2-mm male cables. Warnings Urological electrostimulation is a medical application, which must be carried out under medical supervision.
Page 47
Electrotherapy The program list of electrotherapy permits to choose the current parameters personally, in order to ensure that the specialist have the maximum precision in the currents he/she uses. NEMS Electrotherapy program list includes 192 parameters combinations. NEMS Freq. NEMS 4s-8s NEMS 4s-12s NEMS 4s-20s NEMS 8s-8s...
Page 48
GENERAL NOTES ON ELECTRODE PLACEMENT The correct electrode positioning and the correct choice of their size are critical aspects for the electrostimulation to be effective. To choose the size of the electrodes and as for their positioning it is necessary to refer to the images at the end of this manual.
Page 53
ELECTRODE PLACEMENT FOR MICROCURRENT TREATMENTS Shoulder pain Cervical pain Elbow pain Lumbar pain Sciatica Hip pain Muscle pain (the Knee pain Ankle pain electrodes should be placed on the painful area) REV.01 del 06.12.2017...
NOTE: Before returning the device for repairs, we recommend to read carefully the user instructions contained in the manual and visit Globus website. In case you need to return your product for assistance, contact your dealer or contact Globus Service.
Page 55
Frequently Asked Questions What kind of electrodes should be used for electrostimulation? Use self-adhesive electrodes, which are practical and improve the quality of stimulation. If used with care, they will last for 25-30 applications. The electrodes should be replaced when they have no longer a good connection with the skin. Where should the electrodes be placed? In the back of this manual, there is a comprehensive electrode placement guide (it is not necessary to respect the polarities indicated).
Page 56
How many sessions can I weekly perform? For physical training, consult the technical guide that is available on the Globus website. For fitness and aesthetics programs, the number of sessions depends on the type of treatment: 3-4 sessions per week on alternate days are suggested for toning;...
Page 57
TAB. 201 GUIDA E DICHIARAZIONE DEL COSTRUTTORE – EMISSIONI ELETTROMAGNETICHE – PER TUTTI GLI APPARECCHI ED I SISTEMI GUIDANCE AND MANUFACTURER’S DECLARATION – ELECTROMAGNETIC EMISSIONS – FOR ALL EQUIPMENT AND SYSTEMS GL3K è previsto per funzionare nell’ambiente elettromagnetico sotto specificato. Il cliente o l’utilizzatore del GL3K deve garantire che esso viene usato in tale ambiente.
Page 58
TAB. 202 GUIDA E DICHIARAZIONE DEL COSTRUTTORE – IMMUNITÀ ELETTROMAGNETICA – PER TUTTI GLI APPARECCHI ED I SISTEMI GUIDANCE AND MANUFACTURER’S DECLARATION – ELECTROMAGNETIC IMMUNITY – FOR ALL EQUIPMENT AND SYSTEMS GL3K è previsto per funzionare nell’ambiente elettromagnetico sotto specificato. Il cliente o l’utilizzatore del GL3K deve garantire che esso viene usato in tale ambiente.
Page 59
variazioni di tensione in U in_dip in 230V) ambiente commerciale ospedaliero. Se l’utilizzatore del sulle linee di per_for 0,5 per_for 0,5 ingresso GL3K richiede un funzionamento cicli_cycle cicli_cycle dell’alimentazione continuato anche durante l’interruzione della tensione di rete, Voltage dips, short si raccomanda di alimentare il interruptions and GL3K con un gruppo di continuità...
Page 60
TAB. 204 GUIDA E DICHIARAZIONE DEL COSTRUTTORE – IMMUNITÀ ELETTROMAGNETICA – PER GLI APPARECCHI ED I SISTEMI CHE NON SONO DI SOSTENTAMENTO DI FUNZIONI VITALI GUIDANCE AND MANUFACTURER’S DECLARATION – ELECTROMAGNETIC IMMUNITY – FOR EQUIPMENT AND SYSTEMS THAT ARE NOT LIFE-SUPPORTING GL3K è...
Page 61
RF condotta 3 Veff_Vrms da 80 MHz a 800 MHz Conducted RF 80 MHz to 800 MHz IEC 61000-4-6 da 150 kHz a 80 da 800 MHz a 2,5 GHz 150 kHz to 80 MHz 800 MHz to 2,5 GHz RF irradiata 3 V/m 3 V/m...
Page 62
frequenza Field strengths from fixed transmitters, as determined by an electromagnetic site survey , should be less than the compliance level in each frequency range può verificare interferenza prossimità apparecchi contrassegnati dal seguente simbolo: Interference may occur in the vicinity equipment marked with...
Page 63
considered. If the measured field strength in the location in which the GL3K is used exceeds the applicable RF compliance level above, the GL3K should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the GL3K.
Page 64
Per i trasmettitori specificati per una potenza massima di uscita non riportata sopra, la distanza di separazione raccomandata d in metri (m) può essere calcolata usando l’equazione applicabile alla frequenza del trasmettitore, ove P è la potenza massima d’uscita del trasmettitore in Watt (W) secondo il costruttore del trasmettitore For transmitters rated at a maximum output power not listed above, the recommended separation distance d in metres (m) can be determined using the equation applicable to the frequency of the...