3-5. 4 TIMER OPERATION AND
PROGRAMMING
(Continued)
707
If more than one timer is running at the same time,
the timer with the least amount of time is displayed
and the timer LED flashes. Press a timer button to
view the time remaining for that particular product.
Press and hold the timer button for at least 4 seconds
to stop a running timer.
Temperature Setpoint Programming
Press and hold
for 5 seconds, and the setpoint
temperature flashes. Continue to hold in on
use
to set the desired setpoint temperature.
Releasing
enters the setpoint into the controls. If
"Loc" shows in the display when
the controls must be unlocked before temperature can be
changed. (See Special Program Mode).
Timer Settings
Timer Setpoint:
Press and hold the desired timer button, then use
change the time.
Releasing the timer button enters the time into the
controls. If "Loc" shows in the display when
is pressed, the controls must be unlocked before time can
be changed.(See Special Program Mode)
Pre-Alarm:
While pressing and holding the desired timer button,
press
to view the pre-alarm time and use
change the pre-alarm time.
Releasing the timer button enters the time into the
controls.
When programming the setpoint temperature or
timers, pressing and holding the
the displayed digits.
Also, if several timers are running at once, press the
desired timer button to view the time remaining on
that product.
Model MMP-941
, then
or
is pressed,
to
or
to
or
speeds up
3-4