Event memory

The alarm system stores the last 250 events. To read the
alarm memory:
UK
Enter a valid user code.
The control unit shows:
5
Press:
The LCD display shows the latest events first.
You can page forwards and backwards in the event
memory. Press key 1 to page forwards and key 3 to page
backwards.
Press
to switch between the event and the date.
Press
to exit the event memory.
The event memory cannot be deleted by the programmer
or the user.
Entries in the event memory and their meaning:
Entry
Power fault
Power OK
Alarm
cancellation
AUX DC fault
AUX DC fault
OK
Bad Checksum
Battery fault
Battery fault OK
Break-in zone
nn alarm
Break-in Zone
Meaning
Failure of 230V AC power supply
230V AC power supply restored
Alarm aborted manually by user
12V DC power supply failed or AUX
fuse defect
12V DC power supply restored
Error in alarm centre memory
Failure of battery charger or battery
fuse defect
Battery charger restored
Zone nn has triggered a burglar
alarm
Zone nn OK
nn OK
Factory settings
Factory settings restored
loaded
EEPROM fault
Memory error in the alarm centre
Fire zone nn
Zone nn has triggered a fire alarm
alarm
Fire zone nn
Zone nn reset
reset
Fire zone nn re-
Zone nn re-connected
connected
BDTnn code
A user has tried too often to enter
lock
code in the control unit
BDTnn fault
Control unit nn failed
BDTnn
Control unit nn reconnected
connected
BDTnn Sabo
Control unit has triggered a tamper
alarm
BDTnn Sabo OK Control unit nn tamper reset
BDTnn FE
Fire alarm triggered at control unit nn
Alarm
BDTnn MN
Medical emergency alarm triggered
Alarm
at control unit nn
SSL active ZN
Alarm centre activated via key switch
nn
of zone nn
Entry
Meaning
SSL de-active
Alarm centre deactivated via key
ZN nn
switch of zone nn
SBox ZN nn
Zone nn with key box property closed
closed
SBox ZN nn
Zone nn with key box property
open
opened
Sabo central
The lid contact of the alarm centre
alarm
was triggered
Sabo central
The lid contact of the alarm centre is
alarm OK
closed again
Battery fault
Fault in battery power supply
Battery fault OK
Fault in battery power supply
remedied
BDTnn ÜF
BDT nn has triggered a panic alarm
Alarm
Panic ZN nn
Zone nn has triggered a panic alarm
alarm
Panic ZN nn
Panic alarm of zone nn reset
reset
Aktiv fehlg. ZN
The alarm centre could not be
nn
activated since ZN nn was triggered
14