Bosch Worcester Greenstyle Bewdley 8 Installation, Servicing And User Instructions Manual
Bosch Worcester Greenstyle Bewdley 8 Installation, Servicing And User Instructions Manual

Bosch Worcester Greenstyle Bewdley 8 Installation, Servicing And User Instructions Manual

Multifuel stove-defra exempt smokeless fuel

Advertisement

Quick Links

Installation, servicing and user instructions
Multifuel Stove-Defra Exempt Smokeless Fuel
Greenstyle Bewdley
3, 5 & 8

Advertisement

Table of Contents
loading

Summary of Contents for Bosch Worcester Greenstyle Bewdley 8

  • Page 1 Installation, servicing and user instructions Multifuel Stove-Defra Exempt Smokeless Fuel Greenstyle Bewdley 3, 5 & 8...
  • Page 2: Table Of Contents

    CONTENTS KEY TO SYMBOLS AND SAFETY INSTRUCTIONS ..................3 APPLIANCE INFORMATION ........................4 USER INFORMATION ..........................4-5 INSTALLATION ............................. 6-22 COMMISSIONING ............................23 USER INSTRUCTIONS ..........................24-27 SERVICE AND SPARES ..........................28-33 COMMISSIONING CHECKLIST ........................34 SERVICE RECORD ............................35 6720818040 B 04/2017...
  • Page 3: Key To Symbols And Safety Instructions

    KEY TO SYMBOLS AND SAFETY INSTRUCTIONS 1 KEY TO SYMBOLS AND SAFETY INSTRUCTIONS A REFERENCE TO A RELATED PART IN THE DOCUMENT OR TO OTHER RELATED DOCUMENTS. 1.1 KEY TO SYMBOLS To refer the reader to a specific figure/table/section within the Warnings manual.
  • Page 4: Appliance Information

    APPLIANCE INFORMATION APPLIANCE TECHNICAL DATA The Checklist can be used to demonstrate compliance with TECHNICAL DATA Bewdley 3 Bewdley 5 Bewdley 8 Building Regulations and should be provided to the customer for future reference. Height To Top Of Stove 515mm 515mm 578mm HEALTH AND SAFETY...
  • Page 5 In England, appliances are exempted by publication on a list by the Secretary of State in accordance with changes made to sections 20 Please visit the website: worcester-bosch.co.uk/guarantee so that and 21 of the Clean Air Act 1993 by section 15 of the Deregulation you can register your stove online or via the Worcester Guarantee Act 2015.
  • Page 6: Installation

    INSTALLATION UNPACKING THE APPLIANCE Remove the baffle, louvre assembly, fastener card, log guard, ash handle, flue collar, glove, and ash pan from inside the Slide the box panels up to remove and set aside. firebox of the stove. The Bewdley 8 does not have an ash pan. Contents List Remove the remaining top panel.
  • Page 7 INSTALLATION INSTALLING BAFFLE To locate the bottom of the baffle there is a B3, B5, or B8 (depending on the model purchased) cut into the bottom of the baffle along with two arrows. When reinstalling the baffle be careful not to install the baffle upside down. When correctly installed the B3, B5, or B8 cutout will rest on the clean burn air duct as shown and the arrows will be pointing down.
  • Page 8 INSTALLATION INSTALLING LOUVRES REMOVING THE VERMICULITE SIDE PANELS Secure louvres to stove with the two provided (D) screws. Note: Handle vermiculite side panels with care as they can become fragile after use. Remove the baffle. INSTALLING THE LEG LEVELERS Insert four (4) A bolts into stove and adjust as needed until the unit is level.
  • Page 9 INSTALLATION INSTALLING BEWDLEY 8 BRICKS 6720818040 B 04/2017...
  • Page 10 INSTALLATION 6720818040 B 04/2017...
  • Page 11 INSTALLATION CONVERTING TO USE REAR FLUE Attach the flue collar with four (A) bolts, Four (B) nuts, and four (C) washers. Remove the four (A) Bolts, (C) washers, and (B) nuts. You will need to reach in through the top opening of the stove to gain access to all of the bolts when securing the flue collar.
  • Page 12 INSTALLATION CAUTION! THE APPLIANCE IS VERY HEAVY. ASSISTANCE FROM A SECOND PERSON IS STRONGLY SUGGESTED. PLEASE USE PROPER LIFTING TECHNIQUE WHEN POSITIONING THE APPLIANCE FOR ASSEMBLY AND INSTALLATION. TO PREVENT DAMAGE TO THE LOUVRES DO NOT TILT THE STOVE FORWARD DURING INSTALLATION. Align Holes OPTIONAL LOG STORAGE Align the holes of heat shield and stove.
  • Page 13 INSTALLATION POSITIONING THE STOVE It is very important to position the stove as close as possible to Your stove has been tested to applicable international standards the chimney, and in an area that will favour the most efficient and therefore can be installed on a suitable non-combustible 12 heat distribution possible throughout the house.
  • Page 14 INSTALLATION CONSTRUCTIONAL HEARTH Hearths should be constructed of suitably robust materials and to appropriate dimensions such that, in normal use, they prevent Constructional hearths should have plan dimensions as shown in combustion appliances setting fire to the building fabric and Diagram A below and be made of solid, non-combustible material, furnishings, and they limit the risk of people being accidentally such as concrete or masonry, at least 125mm thick, including the...
  • Page 15 INSTALLATION FREE STANDING STOVE CLEARANCES A stove must never be installed in a hallway or near a staircase, The clearance between the flue pipe and a wall are valid only for since it may block the way in case of fire or fail to respect required vertical walls and for vertical flue pipe.
  • Page 16 INSTALLATION CHIMNEY CONNECTOR (STOVE PIPE) The chimney connector and chimney must be no smaller than the stove To ensure a good draught, the total length of the coupling pipe should outlet 127mm for the Bewdley 3&5, 152mm for the Bewdley 8. If this is never exceed 2.4m to 3.03m.
  • Page 17 Fire Cement INSTALLATION TOP FLUE To chimney connection as detailed in building regulations Seal Collar with Fire Cement 600mm min Self tapping screw 1000mm max unsupported llar with REAR FLUE To chimney connection ection as detailed in building ding regulations 600mm min 1000mm max unsupported...
  • Page 18 INSTALLATION CHIMNEY Approved Document J (see also combustion air supply). Adequate provision e.g. easily accessible soot door or doors must be In order for the stove to perform satisfactorily the chimney height must provided for sweeping the chimney and connecting fluepipe where it is be sufficient to ensure an adequate draught of approximately 15 Pa not intended for the chimney to be swept through the appliance.
  • Page 19 INSTALLATION FLUE OUTLET POSITIONS FOR SOLID FUEL APPLIANCES Adjacent building Adjacent building Regulated building Regulated building weather surface (Notes 1,2) At or within 600mm of the ridge At least 600mm above the ridge Datum for weather surface (Notes 1,2) horizontal At least 2300mm horizontally At or within 600mm of the ridge At least 600mm above the ridge...
  • Page 20 INSTALLATION FACTORY BUILT CHIMNEY When a metal prefabricated chimney is used, the manufacturer’s (where needed), insulation shield, roof flashing, chimney cap, etc. installation instructions must be followed. You must also purchase Maintain proper clearance to the structure as recommended by the (from the same manufacturer) and install the ceiling support manufacturer.
  • Page 21 INSTALLATION Ways of meeting the requirements when proposing factory-made When providing a factory-made metal chimney, provision should metal chimneys include: be made to withdraw the appliance without the need to dismantle • Using component systems appropriately designated in the chimney. accordance with BS EN 1856-1:2003 to suit the appliance Factory-made metal chimneys should be kept a suitable distance and installing them in accordance with the relevant...
  • Page 22 INSTALLATION LOCATION AND SHIELDING OF CONNECTING Connecting fluepipes should be located so as to avoid igniting FLUEPIPES combustible material. Ways of meeting the requirement include Connecting fluepipes should be used only to connect appliances minimizing horizontal and sloping runs and: to their chimneys.
  • Page 23: Commissioning

    COMMISSIONING COMMISSIONING AND HANDOVER CO ALARMS Ensure all parts are fitted in accordance with the instructions. Building regulations require that when ever a new or replacement On completion of the installation allow a suitable period of time for fixed solid fuel or wood/ biomass appliance is installed in a dwelling any fire cement and mortar to dry out, before lighting the stove.
  • Page 24: User Instructions

    USER INSTRUCTIONS Read the instruction booklet and these supplementary instructions carefully before your first fire. MAXIMUM AMOUNT OF FUEL THE FIRST FIRES Do not load fuel above the firebrick. Larger amounts of fuel can lead The fresh paint on your stove needs to be cured to preserve to over firing and therefore damaging the stove or causing damage its quality which may produce some smell.
  • Page 25 USER INSTRUCTION CONTROLLING YOUR STOVE The secondary air slide is located above the viewing glass. (The lower air slide below the glass is primary and is only used for start up air and should not be left open for more than 5 minutes after starting your fire.) Sliding secondary air slide to the far right position is fully open position.
  • Page 26 USER INSTRUCTION Burn new fuel at a high temperature (ie with the primary air This stove was tested using dry beech or birch wood, so only use fully open) for a few minutes to establish a good fire before dry-seasoned wood (preferably hardwood) with a moisture content adjusting down the Primary Air Control.
  • Page 27 USER INSTRUCTION CHIMNEY CLEANING GASKETING The chimney should be swept at least twice a year. It is important It is recommended that you change the door gasket (which makes that the flue connection and chimney are swept prior to lighting up your stove door air tight) once a year, in order to ensure good after a prolonged shutdown period.
  • Page 28: Service And Spares

    SERVICE AND SPARES BEWDLEY 3 6720818040 B 04/2017...
  • Page 29 SERVICE AND SPARES Bewdley 3 Greenstyle Bewdley Stove 7-733-600-202 Part No. Description Qty. 8-716-118-224 Log Guard, 4kW 8-716-118-225 Louvre Weldment, 4kW 8-716-118-226 Ash Pan, 4kW 8-716-118-297 Tool, Ash Pan 8-716-118-227 Grate, 4kW 8-716-118-228 Baffle, 4kW 8-716-118-220 127mm Flue Collar Assembly Kit 8-716-118-221 Clean Burn Air Duct, 4kW Kit 8-716-118-222...
  • Page 30 SERVICE AND SPARES BEWDLEY 5 6720818040 B 04/2017...
  • Page 31 SERVICE AND SPARES Bewdley 5 Greenstyle Bewdley Stove 7-733-600-203 Part No Description Qty. 8-716-118-243 Log Guard, 5kW 8-716-118-244 Louvre Weldment, 5kW 8-716-118-245 Ash Pan, 5kW 8-716-118-297 Tool, Ash Pan 8-716-118-246 Grate, 5kW 8-716-118-247 Baffle, 5kW 8-716-118-220 127mm Flue Collar Assembly Kit 8-716-118-241 Clean Burn Air Duct, 5kW Kit 8-716-118-222...
  • Page 32 SERVICE AND SPARES BEWDLEY 8 6720818040 B 04/2017...
  • Page 33 SERVICE AND SPARES Bewdley 8 Greenstyle Bewdley Stove 7-733-600-204 Part No Description Qty. 8-716-118-258 Log Guard, 8kW 8-716-118-259 Louvre Weldment, 8kW 8-716-118-261 Baffle, 8kW 8-716-118-260 Brick Kit 8-716-118-262 Vermiculite Side Panel, 8kW 8-716-118-254 153mm Flue Collar Assembly Kit 8-716-118-255 Clean Burn Air Duct, 8kW Kit 8-716-118-256 153mm Flue Blank Kit 8-716-118-263...
  • Page 34: Commissioning Checklist

    COMMISSIONING CHECKLIST Commissioning Checklist This Commissioning Checklist is to be completed in full by the competent person who commissioned the stove as a means of s and then handed to the customer to keep for future refer- ence. Failure to install and commission according to the manufacturer e Commissioning Checklist will invalidate the warranty.
  • Page 35: Service Record

    SERVICE RECORD Service Record It is recommended that your heating system is serviced regularly and that the appropriate Service Interval Record is completed. Service Provider: Before completing the appropriate Service Record below, please ensure you have carried out the service as described in the manu- facturer’s instructions.
  • Page 36 0330 123 0166 S ALE S : 0330 123 9669 Worcester, Bosch Group Cotswold Way, Warndon, Worcester WR4 9SW. Worcester, Bosch Group is a brand name of Bosch Thermotechnology Ltd. www.worcester-bosch.co.uk 6 720 818 040 B 04/2017 6720818040 B 04/2017...