Use Of The Control Panel; Using The Control Panel; Shutdown; Frost Protection - Baxi Combi 630 User Manual

High efficiency wall hung condensing gas boiler
Table of Contents

Advertisement

5 Operation
5.2

Use of the control panel

Fig.8

Using the control panel

R
Reset
R
5.3

Shutdown

5.4

Frost protection

16
5.2.1
Important
OpenTherm controller.Your installer will advise you when this type
of control is connected to the boiler. If so, any change to the boiler
settings (e.g. heating temperature) must be made using the
OpenTherm controller not the boiler control panel. Please consult
the user manual for the OpenTherm controller.
2
1
3
0
4
bar
To increase or decrease boiler temperature and/or the domestic hot water
(DHW) temperature:
R
1. Turn the control knob with the symbol
the boiler set temperature. The set temperature will be shown on the
display screen.
PN-0000636
2. Turn the control knob with the symbol
decrease the boiler temperature. The temperature will be shown on
the display screen.
3. Turn the control knob with the symbol
the DHW temperature. The temperature will be shown on the display
screen.
4. Turn the control knob with the symbol
decrease the DHW temperature. The temperature will be shown on
the display screen.
To reset the boiler:
1. Press the
for more than 2 seconds the boiler will not reset. (see List of error
codes, page 21.)
Isolate the mains power supply at the fused spur unit.
Isolate the gas supply at the boiler valve.
Protect the boiler from frost.
Important
The boiler is not protected against frost once it has been shut
down.
Important
If it is anticipated that the boiler will not be used for a long period
or the property is to be unoccupied it is recommended that the
system be drained if the electricity and gas supplies are to be
turned off. Your installer will be able to offer advice.
Where possible, draining the system should be avoided. If the system is to
be unused during winter months several precautions must be taken:
Any parts of the system that are in unheated areas of the dwelling
should be fitted with a device such as a pipe thermostat or frost
thermostat.
Power must remain supplied to the boiler and controls.
Gas must remain supplied to the boiler.
The boiler pump will operate if the system temperature drops below 7°C. If
the temperature falls to 4°C the burner will ignite and remain lit until the
temperature reaches 10°C. At this temperature the burner will extinguish
but the pump will continue to operate for 15 minutes. This feature will
protect the boiler and to some extent adjacent parts of the system but
additional devices must be incorporated to guarantee frost protection.
Using the control panel
button for approximately 1 second, holding the button
Reset
over it clockwise to increase
over it anticlockwise to
over it clockwise to increase
over it anticlockwise to