Refrigerant System Diagram - Mitsubishi Electric SUZ-SWM40VA Technical & Service Manual

Hide thumbs Also See for SUZ-SWM40VA:
Table of Contents

Advertisement

8

REFRIGERANT SYSTEM DIAGRAM

SUZ-SWM40VA.TH
SUZ-SWM60VA.TH
SUZ-SWM80VA.TH
Refrigerant pipe ø 12.7
(with heat insulator)
Stop valve
(with service port)
Flared connection
Flared connection
Stop valve
Refrigerant pipe ø 6.35
(with heat insulator)
OCH718A
Strainer
#100
4-way valve
Strainer
#50
Muffler
Discharge
temperature
thermistor
RT62
Compressor
Capillary tube
ø3.0×ø2.0×200(×6)
LEV
Strainer
#100
Muffler
Capillary tube
ø 4.0 ×ø 2.4 × 100
Outdoor
heat
exchanger
Defrost
thermistor
RT61
Outdoor heat
exchanger
temperature
thermistor
Distributer
RT68
Strainer
R.V. coil
#100
heating ON
cooling OFF
Refrigerant flow in cooling
Refrigerant flow in heating
15
Ambient
temperature
thermistor
RT65
Unit: mm