Crown GL-40FE Installation & Operation Manual page 11

Gas kettles
Table of Contents

Advertisement

Gas Kettles
B. SHUTDOWN
1. STANDBY
1. Place power on switch and thermostat to "OFF" position.
2. COMPLETE
1. Place power on switch and thermostat to "OFF" position.
2. Turn dial on combination control from "ON" position to "OFF" position.
3. Turn any main gas service valves supplying gas to "OFF" position.
C. RE-LIGHTING
1. Turn power switch to "ON" position.
It should be noted that the pilot and electronic ignition do not cycle with the thermostat. A standing pilot is automatically
established and monitored each time the power switch is turned ON. If the pilot is ever extinguished by a momentary external
interruption, the spark igniter will automatically relight it without disturbing the cooking cycle, unless lockout occurs.
Spark Igniter Failure
In the event the spark igniter module fails the unit may still be operated by carefully following these instructions.
1. Turn thermostat to OFF position; completely counterclockwise.
2. Turn power switch to OFF position.
3. WAIT A MINIMUM OF 5 MINUTES BEFORE PROCEEDING.
4. Turn dial on combination control to ON position (if not already on).
5. Turn power switch to ON position.
6. Wait two minutes and ten seconds and then immediately light pilot with long match or taper.
7. After 10 - 15 seconds gas valve will allow main burner gas to flow when thermostat is turned on.
8. The pilot will now stay ignited as long as the power switch remains ON. If power switch is turned OFF, repeat the
above instructions. It is intended that the unit be operated in this manner only in emergency situations and only while
it is attended (do not leave pilot lit overnight; shut off power switch). A qualified serviceman must be called promptly.
Front Panel Controls
POWER SWITCH: ........................ This switch turns the main power to the unit on and off. It must be turned on to heat the
COOKING LIGHT (RED): ............. This light is on whenever the main burner gas is on. On units with standing pilots
LOW WATER LIGHT (AMBER): .. All kettles are supplied with sufficient distilled water in the pressurized jacket. If at any
THERMOSTAT: ............................. The thermostat selects the desired internal kettle operating temperature.
PRESSURE GAUGE:.................... The pressure gauge indicates the internal operating pressure of the kettle. When cold,
SIGHT GLASS: ............................. The sight glass indicates the minimum and maximum water level within the kettle.
PRESSURE RELIEF VALVE: ....... The pressure relief valve is a safety device which prevents the internal kettle pressure
INSTALLATION & OPERATION MANUAL 10199 REV 3 (08/22)
kettle. It should be turned off when the kettle will not be in use for long periods.
this light may be on without the burners being on if the pilot is extinguished. See
Lighting Instructions.
time the water level falls below that required for proper operation, the kettle will not
heat and this light will come on. See "Adding Water" section of Service Instructions.
the gauge should be in the green vacuum zone. If it is not, refer to "Re-establishing
Vacuum" section of Service Instructions. Under normal operation with the kettle empty
(thermostat set at 275 degrees Fahrenheit) the pressure shall reach 30 psi. When
loaded the pressure may be considerably less.
If water level falls below minimum level more distilled water should be added. See
"Adding Water" section of Service Instructions.
from ever exceeding 50 psi. It should never be tampered with.