Operation - Crown GL-40FE Installation & Operation Manual

Gas kettles
Table of Contents

Advertisement

O
PERATION

Operation

Contact the factory, the factory representative or a local service company to perform maintenance and repairs
should the appliance malfunction.
In the event of main burner ignition failure, a 5 minute purge period must be observed prior
In the event you smell gas, shut down equipment at the main shut off valve and contact the
If you smell gas during the lighting procedure, immediately shut off the gas supply until the leak has been corrected.
Gas Control Instructions
Appliance does not require "Lighting" the pilot with a flame.
A. START-UP
1. Turn thermostat to "OFF" position and power switch to "OFF" position.
2. Open control panel access door located on right side at bottom.
3. Turn dial on combination control to "ON" position by rotating control knob counterclockwise. (NOTE: Any gas service
valves exterior to the unit should be open.)
4. Turn "POWER" switch to "ON" position.
5. Set "COOK TEMP" to desired setting. The red "COOKING" pilot will be on until desired setting has been reached.
6. At this time the spark igniter will begin sparking at the pilot until the pilot is ignited, or for ninety seconds (an audible
clicking sound will be evident).
7. When the pilot is ignited the spark igniter will automatically stop and within 15 seconds main burner gas will come on.
If ignition does not occur, after a total of ninety seconds, the unit will lockout, shutting off all gas although the spark
igniter will continue to spark. New installations (where there may be a considerable amount of air in the gas line) may
require the unit to be turned off and immediately back on numerous times after each lockout period until the air is
purged from the gas line.
10
PAGE
OF 32
NOTICE
WARNING
to re-establishing ignition source.
WARNING
local gas company or gas supplier for service.
CAUTION
INSTALLATION & OPERATION MANUAL 10199 REV 3 (08/22)