Chapter 2. Adjustments; Adjustments - Sharp UX-1100 Service Manual

Table of Contents

Advertisement

UX-1100DE
FO-1450DE

CHAPTER 2. ADJUSTMENTS

[1] Adjustments

General
Since the following adjustments and settings are provided for this
model, make adjustments and/or setup as necessary.
1. Adjustments
Adjustments of output voltage (FACTORY ONLY)
1. Install the power supply unit in the machine.
2. Set the recording paper and document.
3. When the document is loaded, power is supplied to the output
lines. Confirm that outputs are within the limits below.
Output voltage settings
CNTH
CNPN
CNCVR
CONTROL PWB
TEL/LIU PWB
CNLIUA
CNLIUA
CNLIUB
CNLIUB
Output
Voltage limits
4.75V ∼ 5.25V
+5V
23.3V ∼ 24.7V
VM (+24V)
2. IC protectors replacement
ICPs (IC Protectors) are installed to protect the motor driver circuit.
ICPs protect various ICs and electronic circuits from an overcurrent
condition.
The location of ICPs are shown below:
CNLIUA
CNLIUB
CNRBN
CNCCD
CNMT
POWER
SUPPLY
PWB
CNPW
Connector
No.
CNPW
Pin No.
1
MG
2
MG
3
MG
4
VM
5
VM
6
DG
7
DG
8
+5V
F100
CONTROL
PWB(TOP SIDE)
(1) F100 (ICP-S07) is installed in order to protect IC's from an over-
current generated in the motor drive circuit. If F100 is open, re-
place it with a new one.
3. Settings
(1) Dial mode selector
DIAL mode (Soft Switch No. SWB4 DATA No. 3)
(step 1) Select "OPTION SETTING".
FUNCTION
KEY:
OPTION SETTING
DISPLAY:
(step 2) Select "DIAL MODE".
KEY:
#
#
DISPLAY:
DIAL MODE
(step 3) Select, using "1" or "2".
KEY:
1
DISPLAY: TONE SELECTED
KEY:
2
DISPLAY:
PULSE SELECTED
(step 4) End, using the "STOP" key.
KEY:
2 – 1
4
PRESS
OR #
Cursor
When initially registering,
the mode shows 2=PULSE.
When registering again, the
# #
mode which was registered
#
#
formerly is shown.
1=TONE, 2=PULSE
STOP

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fo-1450

Table of Contents