Led Indicator On Anybus-S Profinet Irt And Irt Fo Bus Module - Fronius AB Profinet RT Operating Instructions Manual

Robot option
Table of Contents

Advertisement

Available languages

Available languages

(4)
LED indicator on
Anybus-S Profi-
net IRT and IRT
FO bus module
Item
(1)
(2)
(3)
64
Flashes green
Identification of the Anybus-S bus module
twice
Flashes red
Configuration error
once
-
-
-
Flashes red
No station name or no IP address assigned
three times
Flashes red four
Internal fault
times
Off
Switched off or not initialised
-
Bus module initialised, no error
(4)
(3)
Display
Meaning
Lights up green
Connection to port 1 established
Flashing green
Port 1 receiving / transferring data
Off
No connection to port 1 or device is switched off
Lights up green
Online, in operation
-
-
Flashes green
Online, STOP
once
-
-
Off
Offline
-
Lights up green
Bus module initialised, no error
Flashes green
Diagnosis data present
once
Flashes green
Identification of the Anybus-S bus module
twice
Too many bus modules / submodules
I/O of the IO controller configuration too large
Configuration incorrect (no module, wrong module)
(1)
Connection / activity 1
(2)
Communication status
(3)
Module status
(1)
(4)
Connection / activity 2
(2)
Connection to IO controller established
IO controller is in operation
Connection to IO controller established
IO controller is not in operation
No connection to IO Controller