"EXT" LED (4)
The "EXT" LED (4) comes on if the external supply voltage is selected using the "EXT"
jumper (5).
"EXT" jumper
The "EXT" (5) and "INT" (6) jumpers are for choosing between an internal and external
(5)/"INT" jumper
power supply. The factory setting for the jumper is "internal power supply".
(6)
"INT" LED (7)
The "INT" LED (7) comes on if the internal supply voltage is selected using the "INT"
jumper (6).
"VCC" LED (8)
The "VCC" LED (8) comes on when the internal or external supply voltage is connected.
The "VCC" LED indicates that the outbound + 24 V power supply for the modules on the
LocalNet side is OK.
LED indicator on
Anybus-S Profi-
net RT bus
module
Item
(1)
(2)
(3)
(4)
(3)
Display
Meaning
Lights up green
Connection established
Flashing green
Receiving / transferring data
Off
No connection or device switched off
Lights up green
Online, in operation
-
-
Flashes green
Online, STOP
once
-
-
Off
Offline
-
Lights up green
Bus module initialised, no error
Flashes green
Diagnosis data present
once
(1)
Connection/activity
(2)
Communication status
(3)
Module status
(1)
(4)
Not in use
(2)
Connection to IO controller established
IO controller is in operation
Connection to IO controller established
IO controller is not in operation
No connection to IO Controller