3.1 Introduction

All external connections to the Digital I/O option card are made using the 24-pin connector.
The required Weidmüller Minimate B2L 3.5/24 mating connector is supplied.
The digital inputs and outputs are described in the following sections.

3.1.1 Slot selection and input / output numbering

The MotiFlex e100 implements a system of I/O 'banks', with each bank allowing up to 32
inputs and outputs. The I/O available as standard on the MotiFlex e100 always resides in
bank 0. The I/O available on option cards resides in bank 1 if the card is inserted in slot 1, or
bank 2 if the card is inserted in slot 2.
The numbering of bank 1 (slot 1) inputs and outputs always starts at 32, since 0-31 are
reserved by bank 0 (even though only DIN0-DIN2 and DOUT0-DOUT1 are used by a
standard MotiFlex e100).
The numbering of bank 2 (slot 2) inputs and outputs always starts at 64, since 0-31 are taken
by bank 0, and 32-63 are taken by bank 1.
This numbering system is summarized in the following table, and in Figures 3-1 and 3-2.
Bank/Slot
0 Standard drive,
connector X3
1 Option card, top slot
2 Option card, bottom slot
The same numbering system is used when referring to the I/O using the Mint INX and OUTX
keywords; for example DOUT32 is referred to as OUTX(32). See the Mint help file for
details.
MN1950WEN
Digital inputs
DIN0
DIN1
DIN2
DIN32
DIN33
DIN34
DIN35
DIN36
DIN37
DIN64
DIN65
DIN66
DIN67
DIN68
DIN69

Input / Output

3 Input / Output
Digital outputs
DOUT0
DOUT1
DOUT32
DOUT33
DOUT34
DOUT35
DOUT64
DOUT65
DOUT66
DOUT67
Input / Output 3-1