Advertisement

Quick Links

SPLIT SYSTEM AIR CONDITIONER
INSTALLATION INSTRUCTIONS
*SA3BD4M SERIES - 1SN18K, 1SN24K, 1SN30K, 1SN36K, 1SN42K, 1SN48K, 2SN60K
(1.5, 2, 2.5, 3, 3.5, 4 & 5 TON)
IMPORTANT SAFETY INFORMATION ......................2
AIR CONDITIONER INSTALLATION .........................3
General Information ..................................................3
Before You Install this Unit .......................................3
Packaging Removal ..................................................3
Locating the Air Conditioner ....................................3
Clearance Requirements ..........................................3
Ground Level .............................................................3
Roof Mount ...............................................................3
Accessory Mounting Kits..........................................3
SYSTEMS EXPANSION DEVICE ...............................4
Indoor & Outdoor Unit ..............................................4
REFRIGERANT CHARGING ......................................5
ELECTRICAL WIRING ...............................................5
Pre-Electrical Checklist ............................................5
Line Voltage ..............................................................6
Grounding..................................................................6
Thermostat Connections ..........................................6
Low Voltage Connections.........................................6
AIR CONDITIONER MAINTENANCE .........................7
Panel Removal ..........................................................7
Panel Installation .......................................................7
It is your responsibility to know this product better than your customer. This includes being able to install the product
according to strict safety guidelines and instructing the customer on how to operate and maintain the equipment for
the life of the product. Safety should always be the deciding factor when installing this product and using common
sense plays an important role as well. Pay attention to all safety warnings and any other special notes highlighted in
the manual. Improper installation of the unit or failure to follow safety warnings could result in serious injury, death,
or property damage.
These instructions are primarily intended to assist qualified individuals experienced in the proper installation of this
appliance. Some local codes require licensed installation/service personnel for this type of equipment. Please read
all instructions carefully before starting the installation. Return these instructions to the customer's package for
future reference.
DO NOT DESTROY. PLEASE READ CAREFULLY & KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.
START UP & ADJUSTMENTS ...................................8
Pre-Start Check List .................................................8
Start-Up Procedures .................................................8
Air Circulation - Indoor Blower...............................8
System Cooling .......................................................8
System Heating (optional) ......................................8
Charging the Unit in AC Mode ...............................8
System Heating (optional) ......................................8
Charging the Unit in AC Mode .................................8
or higher: .................................................................8
35 degrees F and 65 degrees F .............................9
35 degrees F ...........................................................9
ELECTRICAL DIAGRAMS & TABLES ......................10
Figure 5. Wiring Diagram for *SA3BD4M
Figure 6. Wiring Diagram for *SA3BD4M
INSTALLATION CHECKLIST .....................................12
REPLACEMENT PARTS ............................................12
IMPORTANT
ATTENTION INSTALLERS:
(1.5 - 4 Ton Units) ....................................10
(5 Ton Units) .............................................11
13.4 SEER2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2SN60K and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Nortek 2SN60K

  • Page 1: Table Of Contents

    SPLIT SYSTEM AIR CONDITIONER 13.4 SEER2 INSTALLATION INSTRUCTIONS *SA3BD4M SERIES - 1SN18K, 1SN24K, 1SN30K, 1SN36K, 1SN42K, 1SN48K, 2SN60K (1.5, 2, 2.5, 3, 3.5, 4 & 5 TON) IMPORTANT SAFETY INFORMATION ......2 START UP & ADJUSTMENTS ........8 Pre-Start Check List ..........8 AIR CONDITIONER INSTALLATION ......3...
  • Page 2: Important Safety Information

    IMPORTANT SAFETY INFORMATION WARNING: INSTALLER: Please read all instructions before servicing this equipment. Pay attention to all safety warnings and The information listed below must be followed any other special notes highlighted in the manual. Safety during the installation, service, and operation markings are used frequently throughout this manual to of this unit.
  • Page 3: Air Conditioner Installation

    AIR CONDITIONER INSTALLATION • For installations that are space constrained, one side of the unit, adjacent to the service panel, may have its General Information air side clearance reduced to a minimum of 6 inches. The *SA3BD4M series air conditioner is designed only The other side adjacent to the service panel requires for outdoor rooftop or ground level installations.
  • Page 4: Installation/Verification Of The Systems Expansion Device

    • The maximum recommended interconnecting refrigerant actual unit match. The correct expansion device or kit is line lengths is 75 ft. and the vertical elevation difference available for all approved Nortek listed applications from between the indoor and outdoor sections should not the parts department.
  • Page 5: Refrigerant Charging

    Canadian Nortek does not recommend the use of this product in Electrical Code (CSA C22.1 and/or local codes). unlisted combinations, and the system performance and...
  • Page 6: Line Voltage

    Line Voltage Grounding • A wiring diagram is located on the inside cover of the WARNING: electrical box of the outdoor unit. The installer should become familiar with the wiring diagram before making any electrical connections to the outdoor unit. The unit cabinet must have an uninterrupted or •...
  • Page 7: Air Conditioner Maintenance

    AIR CONDITIONER MAINTENANCE Panel Removal 1. Remove screws securing the panel. 2. Slide the panel up towards the top pan in order to clear WARNING: the bottom flange from the base pan. See Figure 3. Swing the bottom of the panel out and pull the panel To prevent electrical shock, personal injury, or down to remove it from the unit.
  • Page 8: Start Up & Adjustments

    START UP & ADJUSTMENTS 3. Verify HI and LO refrigerant pressures. 4. Allow the system to operate for several minutes and then Pre-Start Check List set the temperature selector above room temperature. √ Verify that the outdoor unit is installed according to all Verify the fan and compressor cycle off with the instructions in this document.
  • Page 9: If The Outdoor Temperature Is Between

    panel. The pressures listed in these tables are for reference only and are to be used in troubleshooting a system. The system should be charged to match the superheat or subcooling targets as previously noted and not to match the system pressures.
  • Page 10: Electrical Diagrams & Tables

    ELECTRICAL DIAGRAMS & TABLES WIRING DIAGRAM Split System Air Conditioner (Outdoor Section) Single Phase NOTES: 1. Disconnect all power before servicing. 1. Couper le courant avant de faire letretien. 2. For supply connections use copper conductors only. 2. Employez uniquement des conducteurs en cuivre. 3.
  • Page 11 BLACK BLUE Figure 6. Wiring Diagram for *SA3BD4M (5 Ton Units)
  • Page 12: Installation Checklist

    Stage-1 Suction Pressure (low side): Fan Motor COMPONENTS: Blower Assembly Fan Grille Cabinet Panels Filter/Driers Expansion Valves Specifications & illustrations subject to change without notice or incurring obligations (03/23). 1041119B O’Fallon, MO, © Nortek Global HVAC LLC 2023. All Rights Reserved. (Replaces 1041119A)

Table of Contents