QSC CXD-Q Series User Manual page 11

Hide thumbs Also See for CXD-Q Series:
Table of Contents

Advertisement

4. FIRMWARE: The Q-SYS Designer fi rmware version. To update the fi rmware:
a. The version you want to use must be installed on your PC,
b. The amplifi er must be connected to the network, and turned on.
c. Open the Q-SYS design containing the amplifi er and select "Save to Core and Run" from the File menu.
d. The amplifi er Q-LAN processor and any other Q-SYS peripherals in the design are automatically updated.
5. GAIN A - D: Displays the current Gain setting for each channel. If channels are combined, they are displayed together. The green background gives
a graphical indication of the Gain.
LAN A / LAN B Screen
Refer to
Figure 17
1. Default IP Address. You can change this and the other parameters in Q-SYS Confi gurator.
LAN A is required, and cannot be turned off.
2. Default Netmask.
3. Default Gateway.
4. LAN B is not required, as indicated by empty fi elds in
Health Screen
Refer to
Figure 18
1. FAN RPM – varies depending on the temperature.
2. PSU TEMP – Temperature of the Power Supply Unit.
• 55º C causes a compromised state for the amplifi er.
• 63º C Mutes Audio
3. Channels A&C, and B&D Temp (Heat Sink Temperature)
• Thermal Limiting starts at 69º C, shows a compromised state
• Thermal Shutdown at 80º C
4. Voltage Rails
• CXD4.3Q & CXD4.5Q
» VRail 1 = +147 VDC +/- 5 V typical
» VRail 2 = -147 VDC +/- 5 V typical
• CXD4.2Q
» VRail 1 = +85 VDC +/- 5 V typical
» VRail 2 = -85 VDC +/- 5 V typical
TD-000438 -01 -A
Figure
17.
11
LAN A
1
IP ADDRESS:
192.168.xxx.xxx
2
NETMASK:
255.255.0.0
3
GATEWAY:
4
LAN B
IP ADDRESS:
NETMASK:
GATEWAY:
— Figure 17 —
HEALTH
1
FAN RPM:
2
PSU TEMP:
A&C Temp:
3
B&D Temp:
VRAIL 1:
4
VRAIL 2:
— Figure 18 —
0.0.0.0
1109
35.3°C
35.4°C
35.3°C
149
-151