Dimplex LIA 0608HXCF M Installation And Operating Instruction page 33

Split air-to-water heat pump with hydrobox
Table of Contents

Advertisement

LIA 0608HXCF M - LIA 1316HXCF M
6
Electrical connection
6.1
Supply voltage / fusing
RCD type
6.2
Control voltage / fusing
6.3
Degree of protection according to EN 60 529 Indoors / outdoors
6.4
Starting current limiter
6.5
Rotary field monitoring
6.6
Starting current
6.7
Nominal power consumption at A7/W35/max. consumption
6.8
Nominal current at A7/W35 / cos φ
6.9
Nominal power consumption at A2/W35
6.10 Power consumption of compressor protection (per compressor)
6.11 Power consumption of fan
7
Complies with the European safety regulations
8
Additional model features
8.1
Type of defrosting
8.2
Frost protection, condensate tray /
Water in device protected against freezing
8.3
Max. operating overpressure (heat source/heat sink)
9
Heat output / cooling capacity / coefficients of performance
(COP)
9.1
Heat output / coefficient of performance (COP)
9.2
Cooling capacity / coefficient of performance (COP)
1. The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation with a flow temperature of 35 °C.
The specified sound pressure level represents the free sound area level. The measured value can vary by up to 16 dB(A), depending on the installation location.
2. In reduced operation, the heat output and the COP are reduced.
3. Note that additional space is required for pipe connection, operation and maintenance.
4. Factory setting 6 kW
5. This data indicates the size and capacity of the system according to EN 14511. For an analysis of the economic and energy efficiency of the system, the bivalence point and
the regulation should be taken into consideration. These figures are only achieved with clean heat exchangers. Instructions for care, commissioning and operation can be found
in the relevant sections of the installation and operation instructions. The specified values have the following meaning, e.g. A7/W35: Heat source temperature 7 °C and heating
water flow temperature 35 °C.
6. Max. intake incl. pipe heater (state of supply)
7. The heat circulating pump and the heat pump controller must always be ready for operation.
8. Indoor and outdoor unit must be connected with two refrigerant pipes (high and low pressure). The length information refers to one section. The specified technical data applies
to a refrigerant pipe length of 3-15 m per section. With a refrigerant pipe over a length of 15 metres, the heat output and the COP are reduced. The maximum permissible pipe
length (without adjusting the refrigerant quantity) is 15 m. The refrigerant quantity pre-filled at the factory is sufficient up to this length. From a single pipe length of over 15 m,
the refrigerant quantity must be adjusted. The maximum permissible pipe length with topping up of refrigerant is 30 m. The specified directives for routing refrigerant pipes
and topping up refrigerant can be found in the installation and operating instructions.
9. You can find additional performance data in the installation and operating instructions.
www.dimplex.de
Outdoor unit
Indoor unit
2 5
5
7
5 8
at A-15 / W35
kW / ---
at A-7 / W35
kW / ---
at A-7 / W55
kW / ---
at A2 / W35
kW / ---
at A7 / W35
kW / ---
at A7 / W45
kW / ---
at A7 / W55
kW / ---
at A10 / W35
kW / ---
at A20 / W35
kW / ---
at A20 / W55
kW / ---
at A25 / W10
kW / ---
at A25 / W20
kW / ---
at A35 / W10
kW / ---
at A35 / W20
kW / ---
452172.66.05-EN · FD 0306
1~/N/PE 230 V (50 Hz) / C20A
1~/N/PE 230 V (50 Hz) / B32A
3~/N/PE 400 V (50 Hz) / B13A
B
1~/N/PE 230 V (50 Hz) / C13A
IP 20 / IP X4
Inverter
Yes
A
--
6
kW
1.24 / 3.22
A
5.4 / 0.97
1.26
kW
W
--
W
100
See CE declaration of conformity
Reverse circulation
Yes / Yes
bar
3.0
EN 14511
9
4.00 / 2.34
9
6.21 / 2.68
9
5.22 / 1.96
9
5.50 / 3.95
9
6.20 / 5.00
9
6.35 / 3.75
9
6.90 / 2.91
9
7.35 / 5.02
9
6.98 / 5.91
9
6.81 / 3.60
9
7.37 / 4.17
9
8.52 / 6.40
9
7.22 / 3.55
9
7.87 / 4.98
English
1~/N/PE 230 V (50 Hz) / C20A
1~/N/PE 230 V (50 Hz) / B32A
3~/N/PE 400 V (50 Hz) / B13A
B
1~/N/PE 230 V (50 Hz) / C13A
IP 20 / IP X4
Inverter
Yes
--
6
2.00 / 3.91
8.7 / 0.97
2.02
--
100
See CE declaration of conformity
Reverse circulation
Yes / Yes
3.0
EN 14511
6.34 / 2.46
8.31 / 3.11
7.05 / 1.97
8.20 / 4.05
10.00 / 5.00
10.00 / 3.80
9.72 / 3.04
10.00 / 5.13
10.70 / 6.72
9.85 / 3.88
8.26 / 4.56
12.00 / 5.79
9.48 / 3.72
12.70 / 4.73
EN-31