Summary of Contents for CPS BlackMax 2 Valve Series

  • Page 1 Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com ® BLACKMAX Digital Manifold Series DIGITAL SERIES Patent No. 9,043,161 OWNER'S MANUAL (English) (Software Version 3.2 or Higher) 2 Valve Series: MD50, MD50HE, l\lll50VHE 4 Valve Series: MD100, MD100HE, MD100VHE...
  • Page 8: Pressure Hold Test

    Large leaks should be found before adding refrigerant. Low cost tracer gas mixtures such as 95% N2 and 5% H2 are popular and can be sensed by a CPS E_MOS leak detector. Main Screen [FIG .1 [TEST].
  • Page 11 hh:mm VACUUM HOLD TEST Inactive Current Vacuum ,nun Level cu-t u Psig n 5 . n n Leak test U lJU duration hh:mm Vacuum Display Screen B) Continue to Evacuate the system to the desired level which is indicated in the upper left display once the desired vacuum level is reached: a.
  • Page 16 EVACUATING PROCEDURES MD50 2 Valve Manifold [FIG.26] MD100 4 Valve Manifold [FIG.27] 1.) Connect Low (A) and High (B) Service hoses to 1.) Connect Low (1) and High (2) Service service ports (E) and (D) hoses to service ports (L) and (H) 2.) Connect hose from tee (C) to Inlet port of 2.) Connect 3/8”...
  • Page 17 CHARGING PROCEDURE - HIGH SIDE High Side Charging should be done on a completely evacuated system. MD50 2 Valve Manifold [FIG.26] MD100 4 Valve Manifold [FIG.27] 1.) A scale should be used to weigh in the charge. Place tank on scale so liquid refrigerant is supplied. 2.) Open Supply tank valve to fill manifold with liquid refrigerant.
  • Page 19: Appendix F (Limited Warranty)

    1 year from the date of purchase, or 15 months from the date of manufacture, whichever is sooner. If any BLACKMAX product is believed to be defective it must be returned to CPS Products. If the product is found to be defective, CPS will repair or replace the item(s), at our option, at no charge.
  • Page 20 If certain malfunctions occur, MD50 and MD100 series will display error messages: oP -Appears in display areas reserved for temperature readings when thermistor sensor connected to that port is open circuited or not connected. Replace sensor with CPS model number TMX3C.