Advertisement
The StudSensor™ HD55 features two scanning modes:
WireWarning® detection automatically detects and alerts the user to live AC wires in StudScan and DeepScan® modes. When AC voltage is detected, the AC WireWarning® icon will be displayed on screen.
Push in the battery door tab at the bottom of the tool and open the door.
Insert a new 9V battery, matching the positive (+) and negative (-) terminals to the icons printed on the back. Snap the battery into place and replace the door.
Zircon stud finders and detectors, particularly those with LCD screens, require and consume a great deal of current from batteries.
For optimal performance, brand-new, recently purchased alkaline batteries are strongly recommended for use in these tools.
If you are experiencing any trouble with your tool, please replace the battery in your tool with a brandnew one, or contact your Zircon dealer or e-mail at techsupport@zircon.com.
For optimum scanning results:
If you're receiving erratic scanning results, it may be a result of humidity, moisture within the wall cavity or drywall, or recently applied paint or wallpaper that hasn't fully dried. While the moisture may not always be visible, it will interfere with tool's sensors. Please allow a few days for the wall to dry out.
Do not rely exclusively on the detector to locate items behind the scanned surface. Use other information sources to help locate items before penetrating the surface. Such additional sources include construction plans, visible points of entry of pipes and wiring into walls, such as in a basement, and in standard 40 and 60 cm stud spacing practices.
Always turn off the power when working near electrical wires.
StudSensor™ HD55 is for use on dry interior walls only.
Note: Sensing depth and accuracy can vary due to moisture, content of materials, wall texture, and paint.
StudSensor™ HD55 can scan effectively through most sheet materials, including:
StudSensor™ HD55 is not designed to scan materials such as:
Move selector switch to the desired mode:
StudScan for finding wood or metal studs or DeepScan® for finding studs behind walls more than 19 mm thick.
Unit will remain off if Power button is not pressed.
Always scan for studs with the scanner placed flat against the wall. Move the mode switch to StudScan, place the tool flat against the wall, then press and hold the Power button. Wait for beep to confirm calibration has completed before moving scanner.
Continue to hold the Power button, then slowly slide unit horizontally across the wall, left or right. As you begin to approach a stud, the outer Target Indication bars will begin to turn on.
When the full Target Indication bars are first displayed across the display, the SpotLite® Pointer and Target Spotlight shine, and a steady tone sounds, you have located the edge of the stud. Mark this spot.
Without releasing Power button, continue scanning beyond marked spot until some Target Indication bars turn off. Slide unit in reverse direction to locate other edge of stud.
Mark this second spot. Centre of stud is midway between the two marks.
WireWarning® detection works continuously in StudScan and DeepScan® modes. When live AC voltage is detected, the WireWarning® indicator will appear on the display. If scanning begins over a live AC wire, the WireWarning® indicator will flash continuously. Use extreme caution in these circumstances or whenever live AC is present.
Electrical field locators may not detect live AC wires if moisture is present in the wall, or if wires are more than 50 mm from the scanned surface, in plastic conduit or behind a plywood shear wall or metallic wall covering.
DO NOT ASSUME THERE ARE NO LIVE ELECTRICAL WIRES IN THE WALL. DO NOT TAKE ACTIONS THAT COULD BE DANGEROUS IF THE WALL CONTAINS A LIVE ELECTRICAL WIRE. ALWAYS TURN OFF THE ELECTRICAL POWER, GAS, AND WATER SUPPLIES BEFORE PENETRATING A SURFACE. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN ELECTRIC SHOCK, FIRE, AND/OR SERIOUS INJURY OR PROPERTY DAMAGE.
(See also OPERATING TIPS)
Situation | Probable Causes | Solutions |
Target Indication bars flash and the unit beeps continuously. |
|
|
Unable to detect studs in StudScan mode. Middle (inner) Target Indication bars turn on or flash in StudScan mode. |
|
|
The READY icon turns on but, when scanning, unit doesn´t do anything else. |
|
|
Working in DeepScan® mode and can´t detect studs. |
|
|
Detects other objects besides studs. |
|
|
You suspect electrical wires, but do not detect any. |
|
|
Area of voltage detection appears much larger than actual wire (AC only). |
|
|
DeepScan, SpotLite, StudSensor, WireWarning, and Zircon are registered trademarks or trademarks of Zircon Corporation.
Visit www.ZirconEurope.com for the most current instructions.
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Advertisement
Need help?
Do you have a question about the StudSensor HD55 and is the answer not in the manual?
Questions and answers