Westinghouse Premium WBCMC 500 Series Installation, Start-Up, Maintenance, Parts, Warranty page 26

Commercial gas fired boilers
Table of Contents

Advertisement

26
Two Pipe Sidewall Venting
with Intake (Elbow) and
Coupling (Exhaust)
EXHAUST
Insert Intake/Exhaust
Screen into Coupling
MAINTAIN 12" MINIMUM
CLEARANCE ABOVE HIGHEST
ANTICIPATED SNOW LEVEL
OR GRADE, WHICHEVER IS
GREATER (TYP)
LP-505-A
06/23/15
Sidewall Venting
with Kit
VENT KIT
MAINTAIN 12" MINIMUM
CLEARANCE ABOVE HIGHEST
ANTICIPATED SNOW LEVEL
OR GRADE, WHICHEVER IS
GREATER (TYP)
LP-505-A
06/23/15
Figure 13 - Two Pipe Sidewall Venting and Sidewall Venting with
Optional Kit (NOT INCLUDED WITH THE BOILER)
NOTE: These drawings are meant to demonstrate system venting
only. The installer is responsible for all equipment and detailing
required by local codes.
All vent pipes must be glued, properly supported, and the exhaust
pitched a minimum of 1/4" per foot back to the boiler to allow
drainage of condensate. When placing support brackets on vent
piping, the first bracket must be within 1 foot of the boiler and
the balance of 4 foot intervals on the vent pipe. Venting must be
readily accessible for visual inspection from the first three feet
from the boiler.
whl-445 Rev. 000 Rel. 014 Date 7.21.20
EXTERIOR WALL
1" MIN.
12" MIN.
INTAKE
Insert Intake/Exhaust Screen
into Open End of Elbow
EXTERIOR
WALL
EXHAUST
B
FRONT VIEW
LP-325-PP
03/31/11
SIDE VIEW
Figure 14 - Horizontal (Snorkel) Venting
NOTES:
A. For every 1" of overhang, the exhaust vent must be located 1" vertical
below overhang (overhang means top of building structure and not
two adjacent walls [corner of building]).
B. Typical installations require 12" minimum separation between
bottom of exhaust outlet and top of air intake.
C. Maintain 12" minimum clearance above highest anticipated snow
level or grade (whichever is greater).
D. Minimum 12" between vents when installing multiple vents.
E. 12" minimum beyond air intake.
EXHAUST
A
AIR INTAKE
C
D
EXHAUST
E
AIR INTAKE
F

Advertisement