Video loss - Video loss is inherent to digital video recording; therefore, Bosch Security
Systems cannot be held liable for any damage that results from missing video information.
To minimize the risk of losing information, we recommend multiple, redundant recording
systems, and a procedure to back up all analog and digital information.
Caution!
Always securely tighten all fittings to ensure a liquid-tight seal. Failure to do so could allow
!
water to enter the housing and damage the units. If a sealant is used, ensure that it is a
neutral cure type. Sealants that release acetic acid may harm electronics. Use drip loops on
the wiring outside the housing.
Always use Teflon tape and sealant on connector threads of any mount (sold separately by
Bosch or user-supplied).
Notice!
Risk of water ingress
Securely seal all fittings and connection points between the device and all mounts to ensure a
liquid-tight seal. Failure to do so could allow water to enter the housing and damage the
device. Always use Teflon tape and sealant on connector threads of any mount (sold
separately by Bosch or user-supplied).
If a sealant is used, ensure that it is a neutral cure type. Sealants that release acetic acid may
harm electronics.
Use drip loops on the wiring outside the housing.
1.5

Connection in applications

24 VAC power source: This unit is intended to operate with a limited power source. The unit
is intended to operate at 24 VAC (if PoE+ is not available). User supplied wiring must be in
compliance with electrical codes (Class 2 power levels).
PoE: Use only approved PoE+ devices. Power-over-Ethernet can be connected at the same
time as a 24 VAC power supply.
If auxiliary power (24 VAC) and PoE+ are applied simultaneously, the camera selects auxiliary
input and shuts off PoE+.
1.6

Important notices

Indoor use only (NDP-5512-Z30C) - The product shall only be used indoors. Ethernet network
should be connected to a network environment, which must comply with the following
conditions:
1.1 The function of the ITE being investigated to IEC 60950-1 is considered not likely to
require connection to an Ethernet network with outside plant routing, including a campus
environment.
1.2 The ITE is to be connected only to PoE networks without routing to the outside plant.