Turning Off Drive Power Using The Gui - Quantum Scalar 50 Replacement Instructions Manual

Removal and replacement instructions
Hide thumbs Also See for Scalar 50:
Table of Contents

Advertisement

Figure 2 Drive Operations
Screen
Turning Off Drive
0
Power Using the GUI
Quantum Scalar 50 Tape Drive Removal and Replacement Instructions
3 Use the up and down arrows to select the tape drive to be replaced and
press
.
Enter
4 User the up and down arrows to select
The tape drive powers down.
For dual half-height tape drive canisters, repeat the tape drive
Note:
power off process for both tape drives in the canister. If you do
not power down both drives before removing the tape drive
canister, operations in progress can be interrupted causing a
backup job to fail and/or leave a tape cartridge in one of the
tape drives.
To turn off drive power using the remote management GUI:
1 On the host computer, open the internet browser software.
2 In the
field, type http://IPaddress/where IP address is the IP
Address
address for the Quantum Scalar 50 library.
Note:
Refer to OCP
3 Enter the username and password and click
Note:
The default username and password is
and password have been changed, check with the network
administrator for the library username and password.
The
page displays (see
Overview
Turning Off Drive Power
and press
pwr off
screen for the library IP address.
Home
OK
figure
3):
Document 81-81770-01 A01
June 2007
.
Enter
.
. If the username
admin
5