  • Page 1 User’ s Gui d e use or use on humans Shop online at omega.com ® e-mail: info@omega.com For latest product manuals: omegamanual.info OSHFV-Series OS-HFV50 Model High Field of View, High Temp, Fixed IR Sensor with 6 digit LCD...
  • Page 2 Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification. The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.
  • Page 3 The OS-HFV50 Model is a non-contact infrared temperature sensor. The electronics are protected by a rugged IP64 aluminum alloy(A6061) housing. They calculate the surface temperature based on the emitted infrared energy of objects and convert the energy into temperature signal. Infrared thermometer is an optoelectronic sensor.
  • Page 4 5. Technical Data Measurement Specifications Model Temperature Range 0°C~1300°C 600°C~1600°C 1 μm Spectral Response 8~14μm 300:1 Field of View 120:1 5 ms Response Time (95%) 150 ms ±1% of reading or ±1.5°C, ±(0.5% of reading+2°C) Accuracy which is greater ±(0.5% of reading+2°C) Repeatability ±0.5% of reading or ±1°C, which is greater...
  • Page 5 The optical diagrams indicate the target spot diameter at any given distance between the target object and the sensing head. The spot size will change in longer distance corresponding to the following drawing. In order to prevent measuring errors the object must be as least as big as the spot size. OS-HFV50-1201-LR OS-HFV50-3001-H1 S 20 9.8...
  • Page 6 (mm) Mechanical Installation The OS-HFV50 Model comes with a standard 3 m cable, a mounting nut and fixed mounting bracket. You can mount the sensor in brackets or cutouts of your own design. For easy mounting and aligning the sensor to the measured object a fixed or adjustable mounting bracket is available. For exact measurement of the object temperature the sensor must be aligned correctly onto the object.
  • Page 7 LCD display Up/Mode Down/Select/Laser Cable connector Sensor Setup: 1. Pressing the up (∧) key and down (∨) keys simultaneously to enter setup function. 2. Press the down (∨) key, when a (-) symbol appears at the right side of the selected function confirming into Setting Mode.
  • Page 8 Air Purge Collar OS-HFV50-APC Please install the driver for USB cable first. After connecting the USB adapter cable to your PC, the system will allocate the infrared thermometer adapter driver automatically. To find out which COM-Port number your computer set, open the device manager (Start – Settings – Control Panel –...
  • Page 9 Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification.
  • Page 10 Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course! Shop online at omega.com TEMPERATURE Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies Wire: Thermocouple, RTD & Thermistor Calibrators & Ice Point References Recorders, Controllers & Process Monitors...