Figure 2. Dip Switch Settings For Internal Dat24 Drives - Certance DAT 24 User Manual

Quantum dat 24: user guide
Table of Contents

Advertisement

Installation
Changing DIP Switch Settings
Figure 2 on page 12 shows the location of DIP switches on the underside of the internal DAT24
drive. Factory-default settings for each switch are also shown in Figure 2 on page 12. These settings
are described in detail on the following pages.
Block of 10 dip switches
S2
S1
SCSI ID Selection
SCSI ID
0
OFF
OFF
1
ON
OFF
2
OFF
ON
3
ON
ON
4
OFF
OFF
5
ON
OFF
6
OFF
ON
7
ON
ON

Figure 2. DIP Switch Settings for Internal DAT24 Drives

NOTE: If you change a DIP switch setting, the new setting does not take effect until you restart
the drive or send a SCSI Bus Reset to the drive.
SCSI ID Switches (Switches 1 through 3)
Switches 1, 2, and 3 correspond to the SCSI device address identification bits 0 (least-significant
bit), 1, and 2 (most-significant bit), respectively. The default setting is SCSI ID 0 (all three switches
OFF).
NOTE: Each SCSI device on a bus must have a unique SCSI ID. The SCSI host controller gener-
ally uses ID 7. In some systems, the boot drive uses ID 0.
Default dip-switch settings:
S3
S4
S5
S6
Key to dip-switch settings:
MRS
Data
Parity
Mode
compression
OFF
All
Enable
Disable
OFF
MRS
OFF
Disable
Enable
only
OFF
ON
ON
ON
ON
Installing an Internal DAT24 Drive
Note:
Drive is shown upside down
S7*
S8
S9
S10
Inquiry
UNIX
String
Self-test
Configuration
Seagate
Enable
see text
Archive
Disable
*Some drives may be factory-configured to
use the Archive inquiry string.
ON
OFF
ON
OFF
12