2 10 5 Electrical connections

on the single phase outdoor unit side

Access to the connection terminals:
- Remove the front panel. Remove the screws and the
front panel.
figure 24 - Access to sinlge phase outdoor unit's
terminal block
- Make the connections in accordance with the diagram
figure 33, page
30.
Terminal block
Interconnection between
the outdoor unit and
the hydraulic unit
figure 25 - Connections to sinlge phase outdoor unit's
terminal block
- 26 -
Remove the screws
and push downwards
Terminal
block
Service panel
Valve cover
Hook (4places)
General
electrical
supply
- Use cable clamps to prevent the conductors from
being disconnected accidentally.
- Use the cover plate to hold the cables against the
insulating plate.
Cable clip
Cover plate
Fix cables so that cables do not make contact with the pipes
(especially on high pressure side).
Do not make power supply cable and connection cable come in
contact with valve (Gas).
Valve (Gas)
figure 26 - Finalisation of connection
to sinlge phase outdoor unit
Installation and operating manual "1533 - EN"
Cable clip
CAUTION
Power supply cable
and connection cable