Grounding

The equipment must be grounded to
reduce the risk of static sparking and
electric shock. An electric or static spark
can cause fumes to ignite or explode. An
improper ground can cause electric shock.
A good ground provides an escape wire for
the electric current.
This sprayer is equipped with a power cord
that has a ground wire and an appropriate
grounding plug.
The plug must be plugged into an outlet that
is properly installed and grounded in
accordance with all local codes and
ordinances.
Do not modify the plug provided; if it does not
fit the outlet, have the proper outlet installed
by a qualified electrician.

Power Requirements

100-120V units require 100-120 VAC,
50/60 Hz, 15A, 1 phase.
230V units require 230 VAC, 50/60 HZ,
10A-16A, 1 phase.
3A6342F

Extension Cords

Use an extension cord with an undamaged
ground contact. If an extension cord is
necessary, use a 3-wire, 12 AWG (2.5 mm
minimum.
NOTE: Smaller gauge or longer extension
cords may reduce sprayer performance.

Pails

Solvent and oil-based fluids: follow local
code. Use only conductive metal pails,
placed on a grounded surface such as
concrete.
Do not place pail on a non-conductive surface
such as paper or cardboard which interrupts
grounding continuity.
Always ground a metal pail: connect a
ground wire to the pail. Clamp one end to the
pail and the other end to a true earth ground
such as a water pipe.
Setup
2
)
ti24584a
17