5.2. Tightening the bolts before first use
After you unpack the pump, and before you use it for the first time, check and tighten external
fasteners. Tighten the fluid cover screws first, then the manifold screws. (Refer to Figure 6 for torque
figures). This keeps the manifolds from interfering with tightening the fluid covers.
After using a day check the fasteners again and adjust the torque if necessary. Recommended
frequency for tightening fasteners varies with pump usage, a general guideline is to retighten fasteners
every two months. (Refer to Figure 6 for torque figures).
Exhaust gas may contain dirtying materials. To avoid polluting your fluid container, place the exhaust
hose away from it. (Refer to Exhaust Air section. Item 5.6) Fasten the pump foot tightly to the platform
with bolts. Always use seals (teflon, etc) when connecting with bolts.
5.3. Compressed connection
A bleed-type master air valve is required in your system to relieve air trapped between this valve and the
pump. Trapped air can cause the pump to cycle unexpectedly, which could result in serious injury,
including splashing in the eyes or on the skin, injury from moving parts, or contamination from hazardous
fluids. See Fig. 7.
1- Refer to the Figure 7 for the connection scheme. Fix these accessories to the wall or to a
bracket. The air line feeding the accessories must be grounded.
2- Install a filter - regulator to the air line. Use a 5μ (micron) air filter. The pressure of liquid
outlet should be level to air regulator's. Air line filter is for cleaning the dust and humidity
coming from the compressor air.
3- Install an air discharge valve below the pump inlet air line. It will be used to discharge
remaining air in the pump. Install the main air valve above all air line accessories and use it to
cut off the main air from the accessories while maintaining or cleaning.
4- Use a flexible air hose between the pump air inlet and accessories at minimum 1/4 inch
(6,35 mm) inner diameter and not longer than 2 meters. For a hose longer than 2 m, enlarge
the inner diameter respectively.
5.4 Important points while connecting compressed air to diaphragm pumpi
1- Pay attention not to let any object enter the pump before connecting to compressed air
system.
2- Before connecting to compressed air system, remove all particles from the system using blown
air.
3- If the hose connections are sealed with teflon tape, wind the tape a few screw teeth before the
end of the connecting accessory to avoid any teflon pieces entering the system.
4- When using screw connections, note not to mis-screw or apply excessive power on the
screws.
Pump
Part
Type
Air valve
RAN 1/4''
Body
P
Manifold
Diaphragm bolt
Figure 7 – Pump parts tightening torque table
Torque
Bolt
N.m
M5
5 - 6
M6
7 - 8
M6
6 - 7
M5
5 - 6
9