S+S Regeltechnik THERMASGARD RPTF Series Operating Instructions, Mounting & Installation

S+S Regeltechnik THERMASGARD RPTF Series Operating Instructions, Mounting & Installation

Pendulum room temperature sensors with passive output
Table of Contents
  • Technische Daten
  • Caractéristiques Techniques
  • Montage et Mise en Service
  • Технические Данные
  • Монтаж И Ввод В Эксплуатацию

Advertisement

Available languages

Available languages

  • ENGLISH, page 6

Quick Links

D G F r
6000-2090-0000-1XX 20900-2021 V105 02 ⁄ 2021
THERMASGARD
® 
D
Bedienungs- und Montageanleitung
Raumpendeltemperaturfühler,
mit passivem Ausgang
G
Operating Instructions, Mounting & Installation
Pendulum room temperature sensors
with passive output
F
Notice d'instruction
Sonde d'ambiance pendulaire,
avec sortie passive
r
Руководство по монтажу и обслуживанию
Датчик температуры в помещении маятникового типа,
с пассивным выходом
RPTF
S+S REGELTECHNIK GMBH
THURN-UND-TAXIS - STR. 22
90411 NÜRNBERG ⁄ GERMANY
FON +49 ( 0 ) 911 ⁄ 5 19 47- 0
mail@SplusS.de
www.SplusS.de
RPTF 1
RPTF 2
CARTONS
ET EMBALLAGE
PAPIER À TRIER

Advertisement

Table of Contents
loading

Summary of Contents for S+S Regeltechnik THERMASGARD RPTF Series

  • Page 1 Руководство по монтажу и обслуживанию Датчик температуры в помещении маятникового типа, с пассивным выходом RPTF 2 S+S REGELTECHNIK GMBH THURN-UND-TAXIS - STR. 22 90411 NÜRNBERG ⁄ GERMANY CARTONS FON +49 ( 0 ) 911 ⁄ 5 19 47- 0 ET EMBALLAGE mail@SplusS.de...
  • Page 2 D G F r RPTF THERMASGARD ®  RPTF 1 Maßzeichnung Dimensional drawing Plan coté Габаритный чертеж mit Kunststoff -Sinterfilter (Standard) SF -K with plastic sinter filter (standard) avec filtre fritté en matière synthétique (standard) с пластиковым спеченным фильтром (стандартное исполнение) M12x1.5 M12x1.5 mit Metall -Sinterfilter (optional)
  • Page 3: Technische Daten

    ®  THERMASGARD RPTF RPTF 1 = Rev. 2021 - V24 RPTF 2 = Rev. 2021 - V15 Widerstandsthermometer THERMASGARD ® RPTF 1 mit passivem Ausgang, das speziell zur Temperatur- 1x Zweileiterschaltung erfassung in größeren Räumen oder Hallen dient. Aufgrund der angewandten Messmethode beim Standard Raumpendel fühler und der Positionierung im Raum wird ein sehr gutes und für den Messraum repräsenta- tives Messergebnis erzielt, da der Fühler gleichmäßig von der umgebenden Raumluft umspült wird.
  • Page 4 Allgemeine Informationen Messprinzip für HLK - (HVAC) -Temperaturfühler allgemein: Das Messprinzip der Temperaturfühler beruht darauf, dass der innen liegende Sensor ein temperaturabhängiges Widerstandssignal abgibt. Die Art des innen liegenden Sensors bestimmt das Ausgangssignal. Man unterscheidet die nachfolgenden passiven ⁄ aktiven Temperatursensoren: a) Pt 100 - Messwiderstand (nach DIN EN 60 751) b) Pt 1000 - Messwiderstand (nach DIN EN 60751) c) Ni 1000 - Messwiderstand (nach DIN EN 43 760, TCR=6180 ppm ⁄...
  • Page 5 Montage und Inbetriebnahme Die Geräte sind im spannungslosen Zustand anzuschließen. Der Hinweise zum mechanischen Ein- und Anbau: Der Einbau hat unter Berücksichtigung der einschlägigen, für den Messort Anschluss der Geräte darf nur an Sicherheitskleinspannung er folgen. gültigen Vorschriften und Standards (wie z. B. Schweißvorschriften usw.) Folgeschäden, welche durch Fehler an diesem Gerät entstehen, sind von zu erfolgen.
  • Page 6: Technical Data

    ®  THERMASGARD RPTF RPTF 1 = Rev. 2021 - V24 RPTF 2 = Rev. 2021 - V15 Resistance thermometer THERMASGARD ® RPTF 1 with passive output is specifically used for tempera- 1x two-wire connection ture detection in larger rooms and halls. Due to the measuring method employed by this pendulum room Standard temperature sensor in combination with its positioning in the room, excellent and room-representative measuring results are achieved as ambient air of the room is steadily washing around the sensor.
  • Page 7 General notes Measuring principle of HVAC temperature sensors in general: The measuring principle of temperature sensors is based on an internal sensor that outputs a temperature-dependent resistance signal. The type of the internal sensor determines the output signal. The following active ⁄ passive temperature sensors are distinguished: a) Pt 100 measuring resistor (according to DIN EN 60 751) b) Pt 1000 measuring resistor (according to DIN EN 60751) c) Ni 1000 measuring resistor (according to DIN EN 43 760, TCR = 6180 ppm ⁄...
  • Page 8 Installation and Commissioning Devices are to be connected under dead-voltage condition. Devices must Notes regarding mechanical mounting and attachment: only be connected to safety extra-low voltage. Consequential damages Mounting shall take place while observing all relevant regulations and standards applicable for the place of measurement (e.g. such as welding caused by a fault in this device are excluded from warranty or liability.
  • Page 9: Caractéristiques Techniques

    ®  THERMASGARD RPTF RPTF 1 = Rev. 2021 - V24 RPTF 2 = Rev. 2021 - V15 Thermomètre à résistance THERMASGARD ® RPTF 1 avec sortie passive conçu spécialement pour la 1 x 2 fils mesure de la température dans des locaux de grandes dimensions ou halles industrielles. La méthode de Standard mesure qui est appliquée avec cette sonde pendulaire suspendue et son positionnement dans l’espace permettent d’obtenir un excellent résultat de mesure représentatif pour l’espace mesuré, du fait que la...
  • Page 10 Généralités Principe de mesure des sondes de température pour applications CVC (HVAC) en général: Le principe de mesure se base sur le fait que le capteur à l’intérieur génère un signal de résistance dépendant de la température. Le signal de sortie est déterminé par le type de capteur qui se trouve à l’intérieur. On distingue les capteurs de température actifs et passifs suivants: a) Pt 100 –...
  • Page 11: Montage Et Mise En Service

    Montage et mise en service Les raccordements électriques doivent être exécutés HORS TENSION. Consignes pour l’installation mécanique : Veillez à ne brancher l’appareil que sur un réseau de très basse tension L'installation doit être effectuée en conformité avec les réglementations de sécurité.
  • Page 12: Технические Данные

    ®  THERMASGARD RPTF RPTF 1 = Rev. 2021 - V24 RPTF 2 = Rev. 2021 - V15 THERMASGARD ® RPTF 1 — это термометр сопротивления с пассивным выходом, служащий для изме- 1 двухпроводное п о д к л ю ч е н и е рения...
  • Page 13 Указания к продуктам Общий принцип измерения для датчика температуры HLK (HVAC): Принцип измерения температуры основан на зависимости электрического сопротивления чувствительного элемента (сенсора), находящего- ся внутри датчика, от температуры. Выходной сигнал сопротивления определяется типом чувствительного элемента. Различают следующие пассивные ⁄ активные чувствительные элементы: а) измерительный...
  • Page 14: Монтаж И Ввод В Эксплуатацию

    Монтаж и ввод в эксплуатацию Приборы следует устанавливать в обесточенном состоянии. Подключение Указания к механическому монтажу: должно осуществляться исключительно к безопасно малому напряжению. Монтаж должен осуществляться с учетом соответствующих, действи- тельных для места измерения предписаний и стандартов (например, Повреждения приборов вследствие несоблюдения упомянутых требований инструкции...
  • Page 15 Reprint in full or in parts requires permission from S+S Regeltechnik GmbH. La reproduction des textes même partielle est uniquement autorisée après accord de la société S+S Regeltechnik GmbH. Перепечатка, в том числе в сокращенном виде, разрешается лишь с согласия S+S Regeltechnik GmbH.
  • Page 16 D G F r Widerstandskennlinien für passive Temperatursensoren Resistance characteristics of passive temperature sensors Courbes caractéristiques pour capteurs de température passive Характеристики сопротивления пассивных датчиков температуры PT 100 PT 1000 Ni 1000 Ni 1000 LM235Z TK 5000 (T1) 81-210 (KP10) °...

This manual is also suitable for:

Thermasgard rptf1Thermasgard rptf2

Table of Contents