Immersion/screw-in/duct temperature sensor with passive output

Advertisement

Available languages

Available languages

  • ENGLISH, page 6

Quick Links

D G F r
6000-3050-0000-2XX 30500-2020 V210 04 ⁄ 2020
THERMASGARD
® 
D
Bedienungs- und Montageanleitung
Tauch- ⁄ Einschraub- ⁄ Kanal-Temperaturfühler,
mit passivem Ausgang
G
Operating Instructions, Mounting & Installation
Immersion ⁄ screw-in ⁄ duct temperature sensor
with passive output
F
Notice d'instruction
Sonde de température à immerger ⁄ à visser ⁄ en gaine,
avec sortie passive
r
Руководство по монтажу и обслуживанию
Погружной ⁄ ввинчиваемый ⁄ канальный датчик температуры,
с пассивным выходом
High-Performance-Verguss gegen Vibration,
mechanischer Belastung und Feuchtigkeit
High-performance encapsulation against
vibration, mechanical stress and humidity
P S - P R O T E C T I O N
P ERF EC T S E N S O R P R O T EC T I O N
S+S REGELTECHNIK GMBH
PIRNAER STRASSE 20
90411 NÜRNBERG ⁄ GERMANY
FON +49 (0) 911 ⁄ 5 19 47- 0
FAX +49 (0) 911 ⁄ 5 19 47- 70
mail@SplusS.de
www.SplusS.de
TF 54 xx
Herzlichen Glückwunsch!
Sie haben ein deutsches Qualitätsprodukt erworben.
Congratulations!
You have bought a German quality product.
Félicitations !
Vous avez fait l'acquisition d'un produit allemand de qualité.
Примите наши поздравления !
Вы приобрели качественный продукт, изготовленный в Германии.
TF 54
(IP 54)
TF 54 - KV
(IP 65)
TF 54 - Q
(IP 65)

Advertisement

loading
Need help?

Need help?

Do you have a question about the THERMASGARD TF 54 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for S+S Regeltechnik THERMASGARD TF 54 Series

  • Page 1 P S - P R O T E C T I O N P ERF EC T S E N S O R P R O T EC T I O N S+S REGELTECHNIK GMBH Herzlichen Glückwunsch! Sie haben ein deutsches Qualitätsprodukt erworben.
  • Page 2 D G F r TF 54 xx THERMASGARD ®  ø70 ~ 80 M20 x1.5 2-Leiteranschluss (Standard) TF 54 xx Maßzeichnung 2-wire connection (Standard) Dimensional drawing ø70 ~ 80 1x 2 fils (Standard) Plan coté Двухпроводное соединение M20 x1.5 Габаритный чертеж (стандартное...
  • Page 3 THERMASGARD ® TF 54 Rev. 2020 - V16 + ID Widerstandsthermometer ⁄ Temperaturfühler THERMASGARD ® TF 54 mit passivem Ausgang, 1x Zweileiterschaltung mit Anschlusskopf aus Aluminium und geradem Schutzrohr. Ein Grundgerät in vier Varianten durch (Standard) Kombination mit Zubehör, z.B. für robuste Anwendungen mit separater Tauchhülse aus Edelstahl. Der Kanafühler dient zur Erfassung von Temperaturen in flüssigen oder gasförmigen Medien.
  • Page 4 Allgemeine Informationen Messprinzip für HLK - (HVAC) -Temperaturfühler allgemein: Das Messprinzip der Temperaturfühler beruht darauf, dass der innen liegende Sensor ein temperaturabhängiges Widerstandssignal abgibt. Die Art des innen liegenden Sensors bestimmt das Ausgangssignal. Man unterscheidet die nachfolgenden passiven ⁄ aktiven Temperatursensoren: a) Pt 100 - Messwiderstand (nach DIN EN 60 751) b) Pt 1000 - Messwiderstand (nach DIN EN 60751) c) Ni 1000 - Messwiderstand (nach DIN EN 43 760, TCR=6180 ppm ⁄...
  • Page 5 Montage und Inbetriebnahme Die Geräte sind im spannungslosen Zustand anzuschließen. Der Anschluss Der Einbau hat unter Beachtung der Übereinstimmung der vorliegenden technischen Parameter der Thermometer mit den realen Einsatzbe- der Geräte darf nur an Sicherheitskleinspannung er folgen. Folgeschäden, dingungen zu erfolgen, insbesondere: welche durch Fehler an diesem Gerät entstehen, sind von der Gewährlei- –...
  • Page 6 THERMASGARD ® TF 54 Rev. 2020 - V16 + ID Resistance thermometer ⁄ temperature sensor THERMASGARD ® TF 54 with passive output, with 1x two-wire connection connecting head made from aluminium and straight protective tube. A basic unit in four variants (standard) through combination with accessories, eg, for robust applications with a separate immersion sleeve made from stainless steel.
  • Page 7 General notes Measuring principle of HVAC temperature sensors in general: The measuring principle of temperature sensors is based on an internal sensor that outputs a temperature-dependent resistance signal. The type of the internal sensor determines the output signal. The following active ⁄ passive temperature sensors are distinguished: a) Pt 100 measuring resistor (according to DIN EN 60 751) b) Pt 1000 measuring resistor (according to DIN EN 60751) c) Ni 1000 measuring resistor (according to DIN EN 43 760, TCR = 6180 ppm ⁄...
  • Page 8 Installation and Commissioning Devices are to be connected under dead-voltage condition. Devices must Before mounting, make sure that the existing thermometer‘s technical parameters comply with the actual conditions at the place of utilization, in only be connected to safety extra-low voltage. Consequential damages particular in respect of: caused by a fault in this device are excluded from warranty or liability.
  • Page 9 THERMASGARD ® TF 54 Rev. 2020 - V16 + ID Thermomètre à résistance / sonde de température THERMASGARD ® TF 54 avec sortie passive, 1x 2 fils tête de raccordement en aluminium et tube de protection droit. Un appareil de base en quatre (Standard) variantes en combinaison avec des accessoires, par ex.
  • Page 10 Généralités Principe de mesure des sondes de température pour applications CVC (HVAC) en général: Le principe de mesure se base sur le fait que le capteur à l’intérieur génère un signal de résistance dépendant de la température. Le signal de sortie est déterminé...
  • Page 11 Montage et mise en service Les raccordements électriques doivent être exécutés HORS TENSION. Effectuer l’installation en respectant la conformité des paramètres techniques correspondants des thermomètres aux conditions d’utilisation Veillez à ne brancher l’appareil que sur un réseau de très basse tension de réelles, notamment : sécurité.
  • Page 12 THERMASGARD ® TF 54 Rev. 2020 - V16 + ID Термометр сопротивления ⁄датчик температуры THERMASGARD ® TF 54 с пассивным выходом, 1 Двухпроводное подключение с присоединительной головкой из алюминия и прямой защитной трубкой. Базовый прибор в четырех (стандартное исполнение) исполнениях благодаря сочетанию с принадлежностями, например, для тяжелых условий приме- нения...
  • Page 13 Указания к продуктам Общий принцип измерения для датчика температуры HLK (HVAC): Принцип измерения температуры основан на зависимости электрического сопротивления чувствительного элемента (сенсора), находящегося внутри датчика, от температуры. Выходной сигнал сопротивления определяется типом чувствительного элемента. Различают следующие пассивные ⁄ активные чувствительные элементы: а) измерительный...
  • Page 14 Монтаж и ввод в эксплуатацию Приборы следует устанавливать в обесточенном состоянии. Подключение Монтаж следует осуществлять с учетом соответствия прилагаемых технических параметров термометра реальным условиям эксплуатации, должно осуществляться исключительно к безопасно малому напряжению. в особенности: Повреждения приборов вследствие несоблюдения упомянутых требований –...
  • Page 15 Reprint in full or in parts requires permission from S+S Regeltechnik GmbH. La reproduction des textes même partielle est uniquement autorisée après accord de la société S+S Regeltechnik GmbH. Перепечатка, в том числе в сокращенном виде, разрешается лишь с согласия S+S Regeltechnik GmbH.
  • Page 16 D G F r Widerstandskennlinien für passive Temperatursensoren Resistance characteristics of passive temperature sensors Courbes caractéristiques pour capteurs de température passive Характеристики сопротивления пассивных датчиков температуры Pt 100 Pt 1000 Ni 1000 Ni 1000 LM235Z TK 5000 (KP10) 1.8 kOhm 10 kOhm 20 kOhm °...

This manual is also suitable for:

Thermasgard tf 54-kvThermasgard tf 54-q