9.3

blower replacement

Blower replacement may be done through either the fi rebox or from the rear of the appliance. Using the rear panel
is recommended.
INSTALLATION THROUGH THE REAR PANEL :
FOR MODEL CDVS280
Turn off the electrical power and the gas supply to the
appliance.
Remove the two combustion air covers and gaskets held on
with 4 screws each. Remove the rear panel held in place with 6
screws.
Remove the 2 screws holding the blower to its mounting plate. Disconnect
the two blower wires.
Replace the blower and reconnect the two wires.
When replacing the rear panel, ensure that the
wires are neither pinched nor interfere with the
blower operation. Ensure that the combustion air
cover plates and gaskets are properly installed and
sealed.
FOR MODEL CS280
Turn off the electrical power and the gas supply to
the appliance.
Remove the 8 screws securing the air intake
manifolds to the rear panel. Remove the rear panel held in place with 6 screws.
Remove the 2 screws holding the blower to its mounting plate. Disconnect the two blower wires.
Replace the blower and reconnect the two wires. When replacing the rear panel, ensure that the wires are
neither pinched nor interfere with the blower operation. Re-secure the air intake manifolds.
INSTALLATION THROUGH THE FIREBOX:
REPLACEMENT BLOWER ACCESS GASKET IS REQUIRED.
Turn off the electrical power and the gas supply to the appliance.
Open the lower control door, the two side doors, and
the fi re viewing door. Remove the logs.
Remove the blower access plate held on with 8 screws.
Disconnect the two blower wires. Remove the blower
bracket held on with 2 screws.
Replace the blower using the existing bracket.
Replace the bracket/blower assembly on the
appliance.
Reconnect the two wires. Hold the
replacement gasket in place and reattach the
blower access plate. Replace the logs. Close all
doors.
Turn the gas supply and electricity back on.
Because the blower is thermally activated, when turned on, it will automatically start approximately 15-30 minutes
after lighting the appliance and will run for approximately 30-45 minutes after the appliance has been turned off.
Use of the fan increases the output of heat.
Drywall dust will penetrate into the blower bearings causing irreparable damage and must be prevented from
coming into contact with the blower or its compartment.
Any damage resulting from this condition is not covered by the warranty policy.
maintenance
BLOWER
white
THERMAL
SWITCH
VARIABLE
SPEED
SWITCH
SCREWS
BLOWER
AIR INTAKE MANIFOLDS
SCREWS
BLOWER ACCESS
PLATE
W415-1429 / E / 05.22.19
EN
35