3.3.2 installing natural vent

Follow the instructions of the natural vent manufacturer for chimney
installation.
A.
Remove and discard the two combustion air cover plates
and gaskets located on the rear panel of the appliance.
B.
Replace the four screws per side to secure the rear panel to
the appliance.
C.
Remove the spill switch bracket from the rear of the adapter.
D.
Gently pull the two wire terminals (located inside the
7" (178mm) fl ue collar at the top of the appliance) out
approximately 8" (203mm).
E.
Bring the wires through the lower hole in the adapter and
out the spill switch opening. To pass the wires through
the hole more easily, temporarily tape the two terminals
together.
F.
With the spill switch opening aligned to the back of the
appliance, push the crimped edge of the adapter in to the
appliance fl ue collar.
G.
Connect the wire terminals to the spill switch and re-secure the
bracket.
H.
Secure the terminal block into place as shown with the screw
supplied.
I.
Unscrew the wire access cover plate from the rear right hand
side below the fi rebox. Remove and discard the gasket.
Remove the knockout from the cover plate and insert the
protective bushing. Pull both spill switch wires through the
bushing taking up any slack. Replace the cover plate. Connect
one wire end to the terminal block and the other end to
terminal 1 of the gas valve. Connect the two wires running
down the left side of the appliance from
the on/off switch to the remaining tab
on the terminal block and to terminal 3
on the gas valve.
For aesthetics, the adapter has been
designed to accept a standard matte
black 7" (178mm) stove pipe and the decorative band (standard with the GS-150KT). Both are available
from your local authorized dealer / distributor.

3.3.3 natural vent

Attach the Natural Vent label, shown, in the control area of the appliance.

3.3.4 combustion air

This appliance needs air for safe operation and must be installed in such a way that adequate combustion air is
available.
ATTACH THIS LABEL IN THE CONTROL AREA OF THE APPLIANCE.
THIS APPLIANCE HAS BEEN CONVERTED TO A NATURAL VENT
ATTACHEZ CET ÉTIQUETTE DANS LA RÉGION DE CONTRÔLE DU FOYER.
CET APPAREIL A ÉTÉ CONVERTI À UN MODÈLE À TIRAGE
NATUREL.
COMBUSTION AIR COVER
NOTE: If not converting, the wires
are rated for high temperatures
and may remain as is in the appli-
ance collar.
TERMINAL BLOCK
MODEL.
installation
PLATES AND GASKET
ADAPTER
SPILL
SWITCH
NO B-VENT ADAPTER
WIRES (GDS28)
WIRE ACCESS
COVER PLATE
W385-0160 / B
W415-1429 / E / 05.22.19
EN
23

Advertisement

Table of Contents
loading

Table of Contents