System setup
Function
1
Select System
Type
If you are not sure
of your heating/
cooling system
type or have other
questions, go to
resideo.com
2
Heat Pump Change-
over Valve (for heat
pumps only)
3
Heating Fan Control
5
Heating Cycle
Rate
6
Heating Cycle
Rate Stage 2
12
Manual/Auto
Changeover
See page 29 for
more information.
13
Smart Response
Technology
See page 28 for
more information.
Settings & Options
Heat/cool: Gas, oil or electric heating with central air conditioning.
0
1
Heat pump: Heat pump without backup or auxiliary heat.
2
Heat only: Gas, oil or hot water heat without central air conditioning.
3
Heat only with fan: Gas, oil or electric heat without central air conditioning.
4
Cool only: Central air conditioning only.
5
Heat pump: Heat pump with backup or auxiliary heating.
6
Heat/Cool Multiple stages: 2 heat stages (wires on W and W2), 2 cooling
stages (wires on Y and Y2).
7
Heat/Cool Multiple stages: 2 heat stages (wires on W and W2), 1 cooling
stage (wire on Y).
8
Heat/Cool Multiple stages: 1 heat stage (wires on W), 2 cooling stages
(wire on Y and Y2).
0
Cooling changeover valve: Use this setting if you connected a wire labeled
"O" to the O/B terminal.
1
Heating changeover valve: Use this setting if you connected a wire labeled
"B" to the O/B terminal.
0
Gas or oil heat: Use this setting if you have a gas or oil heating system
(system controls fan operation).
1
Electric heat: Use this setting if you have an electric heating system
(thermostat controls fan operation).
Gas or oil furnace: Standard gas/oil furnace (less than 90% efficiency).
5
9
Electric furnace: Electric heating systems.
3
Hot water or high-efficiency furnace: Hot water system or gas furnace
(more than 90% efficiency).
1
Gas/oil steam or gravity system: Steam or gravity heat systems.
0
Manual changeover (Heat/Cool/Off).
1
Automatic changeover (Heat/Cool/Auto/Off). Automatically turns on Heat
or Cool based on room temperature. Note: System maintains minimum 3°F
difference between heat and cool settings.
1
On
0
Off