Daikin Altherma F Installer's Reference Manual page 205

Table of Contents

Advertisement

EPRA14~18DAV3+W1 + ETVH16SU18+23EA6V
Daikin Altherma 3 H HT F
4P644738-1 – 2021.02
#
Code
[9.8.5]
N/A
[9.8.6]
N/A
[9.8.7]
N/A
Description
Restriction: Only applicable if [9.8.4]=Smart
grid.
Shows the Smart Grid operation mode sent by
the 2 incoming Smart Grid contacts.
Smart grid operation mode:
Free running
Forced off
Recommended on
Forced on
See also below table (Smart Grid operation
modes).
Restriction: Only applicable if [9.8.4]=Smart
grid.
To set if electrical heaters are allowed.
Allow electrical heaters:
No
Yes
Restriction: Only applicable in case of room
thermostat control, and if [9.8.4]=Smart grid.
To set if room buffering will be enabled.
Enable room buffering:
No: The extra energy from the photovoltaic
panels is only buffered in the DHW tank (i.e.
heat up the DHW tank).
Yes: The extra energy from the photovoltaic
panels is buffered in the DHW tank, and in the
space heating/cooling circuit (i.e. heat up or
cool down the room).
10
Configuration
|
Installer reference guide
205