Section Iii: Solid Fuel Burning Fireplace Installation (Fp) - New Buck Corporation 329B Manual

Table of Contents

Advertisement

(1) Model 329 (FP) may be installed in a masonry fireplace. Minimum fireplace dimension must
be 24" high, 29-1/2" wide, and 6" deep.
(2) For minimum dimensions for sidewall and mantel, see Figure 11.
(3) Center heater in fireplace opening.
(4) NOTE: See "Producing Adequate Ventilation" page 28.
NOTE: Installer of this appliance must mechanically (peel and stick) attach the marking supplied
with this unvented appliance before installing to inside of firebox of solid-fuel burning fireplace or
listed vent less firebox enclosure into which unvented fireplace insert is installed. See example of
marking on page 8 of this manual.
CAUTION: Cutting any sheet-metal parts of solid-fuel burning fireplace or listed vent less
enclosure in which unvented fireplace is to be installed is prohibited.
NOTE: If factory-built fireplace has no gas access hole (s) provided, an access hole of 1.5 inch
(37.5) diameter or less may be drilled through lower sides or bottom of firebox. This access hole
must be plugged with non-combustible insulation after gas supply line has been installed.
Refractory, glass doors, screen rails, screen mesh and solid-fuel log grates (if applicable) can be
removed from fireplace before installing unvented fireplace insert.
Smoke shelves, shields and baffles may be removed if attached by mechanical fasteners.
Trim panels or surrounds shall not seal ventilation openings in fireplace.
NOTE: After unit is positioned in fireplace, mark trim panels as follows:
A.
Set the side panels in place, flat against fireplace. Mark down inside edge of the trim panel
to make a vertical reference line.
SECTION III
INSTALLATION MODEL 329 (FP)
IN SOLID FUEL BURNING FIREPLACES
LEFT SIDE
7"
Figure 11
Figure 7
24"
RIGHT SIDE
6"
29-1/2"
Page 20
24"
20"