M P C S PECI FICAT IO NS
Nominal Size - Tons
Outdoor Unit Model No.
Ambient Temperature
Operating Range - °F
Sound Data
(dBA)
Refrigerant
(R-410A)
Maximum line length with furnished charge - ft.
Additional charge required per ft. - oz.
Compressor
Refrigerant oil charge - oz.
Connections - in.
Maximum refrigerant pipe length - ft.
Max. difference in level of indoor unit - ft.
Outdoor
Fan
Outdoor Coil
Tube outside diameter - in.
Design Pressure
Shipping
Net/Shipping weight (lbs.)
Data
ELECTRICAL DATA
Electrical Characteristics - 60 Hz - 1 Phase
Maximum Overcurrent Protection (MOCP) amps
1
Minimum circuit ampacity (MCA)
2
Outdoor Fan
Motor
NOTE - Extremes of operating range are plus and minus 10% of line voltage.
HACR type circuit breaker or fuse.
1
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
2
Cooling
Heating
Cooling/Heating
Hi/Med/Low
Charge furnished
No. and Type
Refrigerant oil type
Liquid/Gas pipe (flare)
(No.) Diameter - in.
Total air volume - cfm
rpm
Number of rows
Fins per inch
Fin type
Tube type
Net face area - ft.
2
PSIG
Output - W
5
MPC060S4S
60 - 90
32 - 86
50 / 47 / 45
10 lbs. 9 oz.
25
0.32
(1) Rotary
VG74
47.3
3/8 / 7/8
213
98
(2) 22
4500
900
5
1.3
Hydrophilic aluminum
3/8
Rifled copper tubing
13.58
550 / 340
164 / 190
208/230
50
39
85
36
S I N G L E ZO NE | 5 TO N