3.5. Electrical Wiring Diagrams

Abbreviation
Y/G
CAP
FAN
ECM
T1
T2A
T2B
T2
18-24K Wiring Diagram
WIRING DIAGRAM
NOTE1:
CODE PART NAME
1.The parts with dotted line indicates
ECM
optional features.
CAP
2.Remove the short connector of JR1
FAN
when you use the "on-off" function.
T1
3.Remove the short connector of J1
T2
when you use the "WATER LEVEL
SWITCH" function.
T2A
4.
This symbol indicates the element
T2B
is optional, the actual shape shall prevail.
UVLED
OUTPUT
CN43
Output:5VDC
Output:24VAC
Output:12VDC
Output:5VDC
WATER LEVEL
SWITCH
DRY CONTACT
ALARM
DRY CONTACT
WORK
Y/G
NOTE2:
1.The other switches should be set as
"Off" state from factory.
2.The specific use of the switches please
reference to the manual of application.
3.The CN5/CN23/CN33 connect to left and right terminals.
FOR SETTING POWER(DC MOTOR MODEL ONLY
FOR SETTING POWER(DC
MOTOR MODEL ONLY) )
0 0
0 0
0 0
ENC1
ENC1
8 8
8 8
8 8
CODE
CODE
4 4
5 5
7 7
CAPACITY
CAPACITY
≤ ≤ 53
53
54~71
54~71
72~90
72~90
FACTORY
FACTORY ACCORDING TO RELATED MODEL.
ACCORDING TO RELATED MODEL.
SETTING
SETTING
Meaning
Yellow - Green Conductor
Indoor Fan Capacitor
Indoor Fan Motor
Indoor Electronically Commutated Motor
Indoor Room Temperature Sensor
Indoor Coil Inlet Temperature Sensor
Indoor Coil Outlet Temperature Sensor
Indoor Coil Temperature Sensor
INDOOR ECM MOTOR
INDOOR FAN CAPACITOR
INDOOR FAN MOTOR
ROOM TEMP.SENSOR
COIL TEMP.SENSOR
INDOOR COIL INLET TEMP.SENSOR
INDOOR COIL OUTLET TEMP.SENSOR
ECM
M
2
3
4(3)
CN46
CN6
CN29
Output:5VDC
Output:5VDC
Output:15VDC
INDOOR UNIT
J1
MAINBOARD
L and N :230VAC
S and N :0-24VDC
N
L
S
CN11
CN18
0 0
0 0
0 0
0 0
8 8
8 8
8 8
8 8
9 9
8 8
A A
B B
91~105
91~105
106~140
106~140 141~160
141~160
≥ ≥ 161
161
24V THERMOSTATS SETTING
24V THERMOSTATS SETTING
0 0
S3
S3
8 8
CODE
CODE
0~F
0~F
FACTORY
FACTORY
SETTING
SETTING
FOR SETTING NETADDRESS
FOR SETTING NETADDRESS
0 0
S1+S2
S1+S2
8 8
CODE
CODE
0~F
0~F
0~15
0~15
NETADDRESS
NETADDRESS
3
FACTORY
FACTORY
SETTING
SETTING
CN12
Output:24VAC
6
RED
TRANS
RED
BLUE
RED
2
3
2
L1(1) L2(2)S(3)
Y/G
TO OUTDOOR UNIT
19
ON
ON
ON
ON
ON
ON
SW1
SW1
SW3
SW3
SW2
SW2
1 1 2 2 3 3
4 4
1 1 2 2 3 3
4 4
1 1 2 2 3 3
ON~OFF
ON~OFF
ON~OFF
ON~OFF
ON~OFF
ON~OFF
0 0
ON
ON
ON
ON
0 0
ON
ON
1 1 2 2
1 1 2 2
8 8
1 1 2 2
8 8
0~F
0~F
0~F
0~F
16~31
16~31
32~47
32~47
Remote
Control
Output:+12VDC
ON/OFF
CN2
JR1
CN6
CN9
CN10
24V THERMOSTAT
A74404
16023000
ON
ON
ON
ON
S4 S4
SW4
SW4
4 4
1 1 2 2 3 3
4 4
1 1 2 2
ON~OFF
ON~OFF
ON~OFF
ON~OFF
0 0
ON
ON
1 1 2 2
8 8
0~F
0~F
48~63
48~63
4
CN7
CN14
Output:+12VDC
Output:+15VDC
CN11
Output:+5VDC
CN3
E Y X
To CCM
Comm.Bus