NSTALLATION SITE
Never place anything under the indoor unit that you do
not want to get wet.
The unit may sweat when the humidity is over 80% or
when the drain outlet is clogged.
Never place other heating equipment directly beneath
the indoor unit. Subject to deformation caused by
heat.
Do not place TV, radio, stereo, etc. within 1 meter from
the indoor unit and remote controller.
Doing so may cause interference in the picture or
sound.
Do not place objects in direct proximity of the outdoor unit and
do not let leaves and other debris accumulate around the unit.
Leaves are a hotbed for small animals which can enter the unit.
Once in the unit, such animals can cause malfunctions, smoke
or fire when making contact with electrical parts.
O
PERATION PROCEDURE
If a function that is not available is selected, the
message NOT AVAILABLE will appear.
To protect the unit, turn on the main power switch 6
hours before operation.
If the main power supply is turned off during
operation, operation will restart automatically after the
power turns back on again.
Explanation of heating operation
Master-slave unit system (mode batting)
System operation mode cool or heat is determined by the mode
the master unit is in. When the master unit is in cool mode,
respectively heat mode, the system can only operate in cooling,
respectively heating, regardless of the thermostat setting.
When the master unit is OFF, the system mode is determined by
the unit which is switched on first.
NOTE
The master-slave setting is decided upon and set
during installation.
O
PTIMUM OPERATION
Observe the following precautions to ensure the system operates
properly.
Adjust the air outlet properly and avoid direct air flow to room
inhabitants.
Adjust the room temperature properly for a comfortable
environment. Avoid excessive heating or cooling.
Prevent direct sunlight from entering a room during cooling
operation by using curtains or blinds.
Keep doors and windows closed. If the doors and windows
remain open, air will flow out of your room causing a decrease in
the cooling or heating effect.
Never place objects near the air inlet or the air outlet of the unit.
It may cause deterioration in the effect or stop in the operation.
Turn off the main power supply switch to the unit when the unit is
not used for longer periods of time. If the switch is on, it uses
electricity. Before restarting the unit, turn on the main power
supply switch 6 hours before operation for smooth running.
(Refer to
"Maintenance" on page
When the display shows "
a qualified service person to clean the filters. (Refer to
"Maintenance" on page
3)
Operation manual
2
3)
" (time to clean the air filter), ask
F
OLLOWING SYMPTOMS ARE NOT AIR
CONDITIONER TROUBLES
The system does not operate
The system does not restart immediately after the ON/OFF
button is pressed.
If the OPERATION lamp lights, the system is in its normal
operating condition.
It does not restart immediately because one of its safety devices
actuates to prevent the system from being overloaded.
The system will turn on again automatically after three minutes.
The
system
does
not
TEMPERATURE SETTING button is returned to the former
position after pushing.
It does not restart immediately because one of its safety devices
actuates to prevent the system from being overloaded.
The system will turn on again automatically after three minutes.
The system does not start when the display shows "
(EXTERNAL CONTROL ICON) and it flashes for a few seconds
after pressing an operation button.
This is because the system is controlled or disabled by another
controller with a higher priority.
When the display flashes, it indicates that the system cannot be
controlled by this indoor unit.
The system does not start when the display shows "
This indicates that the change-over of the installation is under
centralized control asigned to another unit or to an optional cool/
heat selector connected to the outdoor unit (= master remote
controller).
The indoor unit has to be restarted with the controller.
The system does not start immediately after the power supply is
turned on.
Wait one minute until the micro computer is prepared for
operation.
White mist comes out of a unit
When humidity is high during cooling operation (in oily or dusty
places)
If the inside of an indoor unit is extremely contaminated, the
temperature distribution inside a room becomes uneven. It is
necessary to clean the inside of the indoor unit. Ask your Daikin
dealer for details on cleaning the unit. This operation requires a
qualified service person.
When the system is changed over to HEATING OPERATION
after DEFROST OPERATION.
Moisture generated by DEFROST becomes steam and exits.
Noise of air conditioners
A continuous low "hissing" sound is heard when the system is in
COOLING or DEFROST OPERATION.
This is the sound of refrigerant gas flowing through both indoor
and outdoor units.
A "hissing" sound which is heard at the start or immediately after
the stop of operation or which is heard at the start or
immediately after the stop of DEFROST OPERATION.
This is the noise of refrigerant caused by flow stop and flow
change.
A continuous low "swishing" sound is heard when the system is
in COOLING OPERATION or at a stop.
The noise is heard when the drain pump is in operation.
A "squeaking" sound is heard when the system is in operation or
after the stop of operation.
Expansion and contraction of plastic parts caused by
temperature change makes this noise.