Special Mounting Instructions; Mounting The Measuring Device; Required Tools; Preparing The Measuring Device - Endress+Hauser Proline Promag W 300 PROFINET Operating Instructions Manual

Electromagnetic flowmeter
Table of Contents

Advertisement

Proline Promag W 300 PROFINET
Endress+Hauser
6.1.3

Special mounting instructions

Protective cover
280 (11.0)
146 (5.75)
6.2

Mounting the measuring device

6.2.1

Required tools

For sensor
For flanges and other process connections: Corresponding mounting tools
6.2.2

Preparing the measuring device

1. Remove all remaining transport packaging.
2. Remove any protective covers or protective caps present from the sensor.
3. Remove stick-on label on the electronics compartment cover.
6.2.3

Mounting the sensor

WARNING
L
Danger due to improper process sealing!
Ensure that the inside diameters of the gaskets are greater than or equal to that of the
process connections and piping.
Ensure that the gaskets are clean and undamaged.
Install the gaskets correctly.
1. Ensure that the direction of the arrow on the sensor matches the flow direction of
the medium.
2. To ensure compliance with device specifications, install the measuring device
between the pipe flanges in a way that it is centered in the measurement section.
3. If using ground disks, comply with the Installation Instructions provided.
4. Observe required screw tightening torques .
134 (5.3)
255 (10.0)
12 (0.47)
30 (1.18)
Installation
A0029553
25

Advertisement

Table of Contents
loading

Table of Contents