Endress+Hauser Proline Promag W 400 Technical Information

Endress+Hauser Proline Promag W 400 Technical Information

Electromagnetic flowmeter
Hide thumbs Also See for Proline Promag W 400:
Table of Contents

Advertisement

TI01046D/06/EN/02.13
71218295
The flowmeter with integrated web server and a sensor with EN ISO 12944
corrosion protection
Application
• The electromagnetic measuring principle is unaffected by
pressure, temperature and flow profile
• The specialist in the water and wastewater industry for the
most demanding applications
Device properties
• International drinking water approvals
• Degree of protection IP68 (Type 6P enclosure)
• Approved for custody transfer to MI-001/OIML R49
• Transmitter housing made of durable polycarbonate
• Same housing concept for compact/remote version
• Integrated data logger: measured values monitoring
Products

Technical Information

Proline Promag W 400
Electromagnetic flowmeter
Solutions
Your benefits
• For direct underground installation or permanent
underwater use
• Safe, reliable long-term operation – robust and completely
welded sensor
• Energy-saving flow measurement – no pressure loss due to
cross-section constriction
• Maintenance-free – no moving parts
• Safe operation – no need to open the device due to display
with touch control, background lighting
• Time-saving local operation without additional software and
hardware – integrated web server
• Integrated verification – Heartbeat Technology™
Services

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Proline Promag W 400 and is the answer not in the manual?

Questions and answers

Jan Nel
April 21, 2025

How do you select the pipe dimensions and the flange types and sizes for this sensor

1 comments:
Mr. Anderson
May 10, 2025

To select pipe dimensions and flange types and sizes for the Endress+Hauser Proline Promag W 400 sensor:

1. Pipe Dimensions:
- Supported nominal diameters (DN):
- DN 25 to 1200 (1" to 48") for polyurethane liners.
- DN 50 to 2000 (2" to 78") for hard liners.
- DN 25 to 300 (1" to 12") or DN 350 to 2000 (14" to 78") for stainless steel measuring tubes.

2. Measuring Tube Material:
- Stainless steel 202, 1.4301 (304), or 1.4306 (304L).

3. Flange Types and Coatings:
- Carbon steel flanges with:
- Al/Zn protective coating for DN 25 to 300.
- Protective varnish (IP68) for DN 50 to 300 and DN 350 to 2000.

Choose the size and flange type based on your pipe diameter and environmental protection needs.

This answer is automatically generated

Subscribe to Our Youtube Channel

Summary of Contents for Endress+Hauser Proline Promag W 400

  • Page 1: Technical Information

    Products Solutions Services TI01046D/06/EN/02.13 71218295 Technical Information Proline Promag W 400 Electromagnetic flowmeter The flowmeter with integrated web server and a sensor with EN ISO 12944 corrosion protection Application Your benefits • The electromagnetic measuring principle is unaffected by • For direct underground installation or permanent...
  • Page 2: Table Of Contents

    Proline Promag W 400 Table of contents Document information ..... . . 3 Electromagnetic compatibility (EMC) ....
  • Page 3: Document Information

    Proline Promag W 400 Document information Symbols used Electrical symbols Symbol Meaning Direct current A terminal to which DC voltage is applied or through which direct current flows. A0011197 Alternating current A terminal to which alternating voltage is applied or through which alternating current flows.
  • Page 4: Function And System Design

    Proline Promag W 400 Symbol Meaning Hazardous area Indicates a hazardous area. A0011187 Safe area (non-hazardous area) Indicates a non-hazardous area. A0011188 Function and system design Measuring principle Following Faraday' s law of magnetic induction, a voltage is induced in a conductor moving through a magnetic field.
  • Page 5: Measuring System

    IT security measures in line with operators' security standards and designed to provide additional protection for the device and device data transfer must be implemented by the operators themselves. Endress+Hauser can be contacted to provide support in performing this task. Endress+Hauser...
  • Page 6: Input

    Proline Promag W 400 Input Measured variable Direct measured variables • Volume flow (proportional to induced voltage) • Electrical conductivity In custody transfer: only volume flow and electrical conductivity Calculated measured variables Mass flow Measuring range Typically v = 0.01 to 10 m/s (0.03 to 33 ft/s) with the specified accuracy Electrical conductivity: 5 to 10 000 µS/cm/cm...
  • Page 7 Proline Promag W 400 Nominal Recommended Factory settings diameter flow Full scale value current min./max. full scale value Pulse value Low flow cut off output (v ~ 0.3/10 m/s) (~ 2 pulse/s) (v ~ 0.04 m/s) (v ~ 2.5 m/s)
  • Page 8: Operable Flow Range

    Proline Promag W 400 Nominal Recommended Factory settings diameter flow Full scale value current min./max. full scale value Pulse value Low flow cut off output (v ~ 0.3/10 m/s) (~ 2 pulse/s) (v ~ 0.04 m/s) (v ~ 2.5 m/s)
  • Page 9 Proline Promag W 400 Resolution 0.5 µA Damping Adjustable: 0.07 to 999 s Assignable measured • Volume flow variables • Mass flow • Flow velocity • Conductivity • Electronics temperature Pulse/frequency/switch output Function • With the order code for "Output; Input", option H: output 2 can be set as a pulse or frequency output •...
  • Page 10: Signal On Alarm

    Proline Promag W 400 EtherNet/IP Standards In accordance with IEEE 802.3 Signal on alarm Depending on the interface, failure information is displayed as follows: Current output 4-20 mA Failure mode Selectable (as per NAMUR recommendation NE 43): • Minimum value: 3.6 mA •...
  • Page 11: Low Flow Cut Off

    Proline Promag W 400 Operating tool • Via digital communication: HART protocol • Via service interface Plain text display With information on cause and remedial measures Additional information on remote operation (→  84) Web browser Plain text display With information on cause and remedial measures...
  • Page 12 Proline Promag W 400 EtherNet/IP Protocol • The CIP Networks Library Volume 1: Common Industrial Protocol • The CIP Networks Library Volume 2: EtherNet/IP Adaptation of CIP Communication type • 10Base-T • 100Base-TX Device profile Generic device (product type: 0x2B)
  • Page 13 Proline Promag W 400 Input Assembly • Current device diagnostics • Volume flow • Mass flow • Temperature • Totalizer 1 • Totalizer 2 • Totalizer 3 Configurable Input 5 ms to 10 s (factory setting: 20 ms) Exclusive Owner Multicast...
  • Page 14: Power Supply

    Proline Promag W 400 Configuration Configuration Assembly Only the most common configurations are listed below. • Software write protection • Mass flow unit • Mass unit • Volume flow unit • Volume unit • Density unit • Reference density unit •...
  • Page 15 Proline Promag W 400 Signal transmission 0-20 mA/4-20 mA HART with additional outputs and inputs Order code for Terminal numbers "Output" and Output 1 Output 2 Output 3 Input "Input" 26 (+) 27 (-) 24 (+) 25 (-) 22 (+)
  • Page 16: Pin Assignment, Device Plug

    Proline Promag W 400 Supply voltage Order code for "Power supply" Terminal numbers 1 (L+/L) 2 (L-/N) Option L AC100 to 240 V (wide range power unit) AC/DC24 V EtherNet/IP signal transmission Order code for "Output" Connection via Option N...
  • Page 17: Power Consumption

    Proline Promag W 400 Supply voltage Transmitter Order code for "Power supply" Terminal voltage Frequency range AC100 to 240 V 50/ 60 Hz, ±4 Hz Option L AC/DC24 V 50/ 60 Hz, ±4 Hz Power consumption Order code for Maximum "Output"...
  • Page 18 Proline Promag W 400 • Fix the cable run or route it in an armored conduit. Cable movements can influence the measuring signal especially in the case of low fluid conductivities. • Route the cable well clear of electrical machines and switching elements.
  • Page 19 Proline Promag W 400 Pulse/frequency output – – 12345 A0016801  6 Connection example for pulse/frequency output (passive) Automation system with pulse/frequency input (e.g. PLC) Power supply Transmitter: observe input values (→  9) EtherNet/IP A0016805  7 Connection example for EtherNet/IP Control system (e.g.
  • Page 20: Potential Equalization

    Proline Promag W 400 Potential equalization Requirements Please consider the following to ensure correct measurement: • Same electrical potential for the fluid and sensor • Company-internal grounding concepts • Pipe material and grounding Connection examples for standard situations Metal, grounded pipe A0016315 ...
  • Page 21 For remote device versions, the ground terminal in the example always refers to the sensor and not to the transmitter. The ground cable and ground disks can be ordered from Endress+Hauser (→  87). Pipe with a cathodic protection unit This connection method is only used if the following two conditions are met: •...
  • Page 22: Terminals

    Guide the shield of the signal lines through a capacitor. For remote device versions, the ground terminal in the example always refers to the sensor and not to the transmitter. The necessary ground cable can be ordered from Endress+Hauser . Terminals Transmitter •...
  • Page 23 Core reinforcement Cable shield Outer jacket A connecting cable can be ordered from Endress+Hauser for IP68: • Pre-terminated cables that are already connected to the sensor. • Pre-terminated cables, where the cables are connected by the customer onsite (incl. tools for...
  • Page 24: Performance Characteristics

    Proline Promag W 400 Operation in zones of severe electrical interference The measuring system meets the general safety requirements (→  85) and EMC specifications (→  32). Grounding is by means of the ground terminal provided for the purpose inside the connection housing.
  • Page 25: Repeatability

    Proline Promag W 400 0.5 % 0.2 % 10 [m/s] 32 [ft/s] A0017051  15 Flat Spec in % o.r. Flat Spec flow values0.5 % Nominal diameter [mm] [in] [m/s] [ft/s] 25 to 600 1 to 24 1.64 Flat Spec flow values0.2 %...
  • Page 26: Installation

    Proline Promag W 400 Pulse/frequency output Temperature coefficient Max.±0.5 ppm v.M./°C Installation No special measures such as supports are necessary. External forces are absorbed by the construction of the device. Mounting location Preferably install the sensor in an ascending pipe, and ensure a sufficient distance to the next pipe elbow: h ≥...
  • Page 27: Orientation

    Proline Promag W 400 A0017063 For very heavy sensors If the nominal diameter DN ≥ 350 (14 in), mount the sensor on a foundation of adequate load- bearing strength. Do not support the weight of the sensor on the metal casing as this could damage the metal casing and the internal magnetic coils.
  • Page 28: Inlet And Outlet Runs

    Proline Promag W 400 A0016260  17 Horizontal orientation EPD electrode for empty pipe detection Measuring electrodes for signal detection Reference electrode for potential equalization If possible, install the sensor upstream from fittings such as valves, T-pieces or elbows. Inlet and outlet runs Observe the following inlet and outlet runs to comply with accuracy specifications: •...
  • Page 29: Length Of Connecting Cable

    Proline Promag W 400 [mbar] 8 m/s 7 m/s 6 m/s 5 m/s 4 m/s max. 8° 3 m/s 2 m/s 1 m/s d / D A0016359 Length of connecting cable To ensure correct measuring results when using the remote version, observe the maximum permitted cable length L .
  • Page 30: Installing The Wall-Mount Housing

    ø ( 0.79…2.75) SW 8 A0020705 A separate mounting kit can be ordered from Endress+Hauser for pipe mounting (→  87). Special mounting Display protection instructions To ensure that the optional display protection can be easily opened, maintain the following minimum head clearance: 350 mm (13.8 in)
  • Page 31: Environment

    • Protect the display against impact. • Protect the display from abrasion by sand in desert areas. A display protector can be ordered from Endress+Hauser: "Accessories" section (→  87) Storage temperature The storage temperature corresponds to the operating temperature range of the measuring transmitter and the appropriate measuring sensors.
  • Page 32: Electromagnetic Compatibility (Emc)

    Proline Promag W 400 Electromagnetic • As per IEC/EN 61326 and NAMUR Recommendation 21 (NE 21) • Complies with emission limits for industry as per EN 55011 (Class A) compatibility (EMC) Details are provided in the Declaration of Conformity. Process Medium temperature range •...
  • Page 33 Proline Promag W 400 Flange connection according to EN 1092-1 (DIN 2501) [psi] [bar] PN 40 PN 25 PN 16 PN 10 PN 6 -60 -40 -20 0 20 40 60 80 100120140 160180 [°C] 360 [°F] A0021184-EN  20 Fixed flange PN 6/10/16/25/40, material 1.4571 (316L), DN 25 to 2000 (1 to 78")
  • Page 34 Proline Promag W 400 Flange connection according to ASME B16.5 [psi] [bar] Class 300 Class 150 -40 -20 0 20 40 60 80 100120140 160180 [°C] 360 [°F] A0021185-EN  22 Fixed flange Class 150/300, material 316L, DN 25 to 600 (1 to 24")
  • Page 35: Pressure Tightness

    Proline Promag W 400 Flange connection according to JIS B2220 [psi] [bar] -40 -20 0 20 40 60 80 100120140 160180 [°C] 360 [°F] A0021183-EN  25 Fixed flange 10K/20K, materials HII, S235JRG2 and 1.0425 (316L), DN 25 to 300 (1 to 12")
  • Page 36: Vibrations

    • After putting the device into circulation or after sealing the device, operation is only possible to a limited extent. • Detailed ordering information is available from your local Endress+Hauser sales center for national approvals as cold water meters based on OIML R49.
  • Page 37: Mechanical Construction

    Proline Promag W 400 Mechanical construction Design, dimensions Compact version Order code for "Housing", option M "Compact, polycarbonate" or option A "Compact, coated aluminum" with DN 25 to 300 (1 to 12") A0020352 Dimensions in SI units [mm] [mm] [mm]...
  • Page 38 Proline Promag W 400 [in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in] 7.60 4.06 3.54 6.57 9.72 4.29 14.0 7.09 3.70 7.87 7.60 4.06 3.54 6.57 9.72 4.29 14.0 7.09 3.70 9.84 7.60 4.06 3.54 6.57 11.3 5.91...
  • Page 39 Proline Promag W 400 [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] EN (DIN), AS, JIS; For flanges according to AS, only nominal diameters DN 80, 100 and 150 to 300 are available. The length is independent of the selected pressure rating. Length in accordance with DVGW/ISO.
  • Page 40 Proline Promag W 400 [mm] [mm] [mm] [mm] [mm] [mm] [mm] Dimension E EN (DIN) ASME PN 10 PN 16 PN 25 PN 40 Class Class Table E PN 16 [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] –...
  • Page 41 Proline Promag W 400 Dimension H EN (DIN) ASME PN 10 PN 16 PN 25 PN 40 Class Class Table E PN 16 [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] – – – – – –...
  • Page 42 Proline Promag W 400 Dimension H EN (DIN) ASME PN 10 PN 16 PN 25 PN 40 Class Class Table E PN 16 [in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in] – 15.5 – 15.8 15.4 16.1 15.5...
  • Page 43 Proline Promag W 400 Dimension E EN (DIN) ASME PN 10 PN 16 PN 25 PN 40 Class Class Table E PN 16 [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] – – – – – –...
  • Page 44 Proline Promag W 400 [in] [in] [in] [in] [in] [in] [in] 7.83 4.69 3.15 6.57 13.8 12.7 7.83 4.69 3.15 6.57 17.7 14.0 7.83 4.69 3.15 6.57 19.7 15.0 Dimension E EN (DIN) ASME PN 10 PN 16 PN 25...
  • Page 45 Proline Promag W 400 Order code for "Housing", option M "Compact, polycarbonate" or option A "Compact, coated aluminum" with DN 350 to 2000 (14 to 78") A0017154 Dimensions in SI units [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm]...
  • Page 46 Proline Promag W 400 [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] 1800 1338 1188 2526 1632 2376 2340 2000 1388 1238 2626 1732 2476 2600 EN (DIN), AS; For flanges according to AS, only nominal diameters DN 350, 400, 500 and 600 are available.
  • Page 47 Proline Promag W 400 Order code for "Housing", option Q "Compact, polycarbonate, inclined" or option R "Compact, coated aluminum, inclined" with DN 350 to 2000 (14 to 78") 22.5° A0020396 Dimensions in SI units [mm] [mm] [mm] [mm] [mm] [mm]...
  • Page 48 Proline Promag W 400 [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] 1800 1383 1188 2571 1632 2376 2340 2000 1433 1238 2671 1732 2476 2600 EN (DIN), AS; For flanges according to AS, only nominal diameters DN 350, 400, 500 and 600 are available.
  • Page 49 Proline Promag W 400 Order code for "Housing", option M "Compact, polycarbonate" or option A "Compact, coated aluminum"; order code for "Design", option A Insertion length short" with DN 350 to 2000 (14 to 78") A0017153 Dimensions in SI units...
  • Page 50 Proline Promag W 400 Dimension F Dimension G EN (DIN) ASME EN (DIN) ASME PN 6 PN 10 PN 16 AWWA PN 6 PN 10 PN 16 AWWA [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] –...
  • Page 51 Proline Promag W 400 [in] [in] [in] [in] [in] [in] [in] [in] 7.60 4.06 3.54 6.57 43.4 50.6 64.9 7.60 4.06 3.54 6.57 45.7 54.3 70.8 7.60 4.06 3.54 6.57 50.1 61.8 78.7 Dimension F Dimension G EN (DIN) ASME...
  • Page 52 Proline Promag W 400 Order code for "Housing", option Q "Compact, polycarbonate, inclined" or option R "Compact, coated aluminum, inclined"; order code for "Design", option A "Insertion length short" with DN 350 to 2000 (14 to 78") 22.5° A0020393 Dimensions in SI units...
  • Page 53 Proline Promag W 400 Dimension F Dimension G EN (DIN) ASME EN (DIN) ASME PN 6 PN 10 PN 16 AWWA PN 6 PN 10 PN 16 AWWA [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] –...
  • Page 54 Proline Promag W 400 [in] [in] [in] [in] [in] [in] [in] [in] 7.83 4.69 3.15 6.57 45.2 50.6 64.9 7.83 4.69 3.15 6.57 47.5 54.3 70.8 7.83 4.69 3.15 6.57 51.9 61.8 78.7 Dimension F Dimension G EN (DIN) ASME...
  • Page 55 Proline Promag W 400 Transmitter remote version Order code for "Housing", option N "Remote, polycarbonate" or option P "Remote, coated aluminum" A0020522 Dimensions in SI units [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] Dimensions in US units [in] [in]...
  • Page 56 Proline Promag W 400 Sensor remote version DN 25 to 300 (1 to 12") A0017282 Dimensions in SI units [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] EN (DIN), AS, JIS; For flanges according to AS, only nominal diameters DN 80, 100 and 150 to 300 are available.
  • Page 57 Proline Promag W 400 [in] [in] [in] [in] [in] [in] [in] [in] 5.35 12.7 8.07 20.8 15.8 6.14 17.7 5.35 13.7 9.06 22.8 18.1 6.54 19.7 ASME The length is independent of the selected pressure rating. Length in accordance with DVGW/ISO.
  • Page 58 Proline Promag W 400 Dimension C EN (DIN) ASME PN 10 PN 16 PN 25 PN 40 Class Class Table E PN 16 [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] – – – – – –...
  • Page 59 Proline Promag W 400 [in] [in] [in] [in] 4.41 11.0 13.8 4.41 12.3 17.7 4.41 13.3 19.7 Dimension C EN (DIN) ASME PN 10 PN 16 PN 25 PN 40 Class Class Table E PN 16 [in] [in] [in] [in]...
  • Page 60 Proline Promag W 400 DN 350 to 2000 (14 to 78") A0017283 Dimensions in SI units [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] 1149 1024 1149 1024 1192 1067 1040 1345 1220 1170 1000 1497 1372 1300 1050 1549...
  • Page 61 Proline Promag W 400 Dimensions in US units [in] [in] [in] [in] [in] [in] [in] [in] 5.35 16.0 11.1 29.3 22.2 10.9 21.7 5.35 17.0 12.1 31.3 24.2 10.9 23.6 5.35 17.0 12.1 31.3 24.2 10.9 23.6 5.35 18.0 13.1 33.3...
  • Page 62 Proline Promag W 400 Dimensions in SI units [mm] [mm] [mm] [mm] [mm] 1000 1000 1050 1050 1200 1200 1350 1008 1350 1400 1008 1400 1500 1025 1147 1500 1600 1025 1147 1600 1650 1076 1284 1650 1800 1133 1379...
  • Page 63 Proline Promag W 400 Dimension C Dimension D EN (DIN) ASME EN (DIN) ASME PN 6 PN 10 PN 16 AWWA PN 6 PN 10 PN 16 AWWA [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] 1500 –...
  • Page 64 Proline Promag W 400 Dimension C Dimension D EN (DIN) ASME EN (DIN) ASME PN 6 PN 10 PN 16 AWWA PN 6 PN 10 PN 16 AWWA [in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in] –...
  • Page 65 Proline Promag W 400 Dimensions in SI units [mm] [mm] [mm] [mm] [mm] 1000 1000 1050 1050 1200 1200 1350 1008 1350 1400 1008 1400 1500 1031 1147 1500 1600 1031 1147 1600 1650 1082 1284 1650 1800 1139 1379...
  • Page 66 Proline Promag W 400 Dimension C Dimension D EN (DIN) ASME EN (DIN) ASME PN 6 PN 10 PN 16 AWWA PN 6 PN 10 PN 16 AWWA [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] 1500 –...
  • Page 67 Proline Promag W 400 Dimension C Dimension D EN (DIN) ASME EN (DIN) ASME PN 6 PN 10 PN 16 AWWA PN 6 PN 10 PN 16 AWWA [in] [in] [in] [in] [in] [in] [in] [in] [in] [in] [in] –...
  • Page 68 Proline Promag W 400 Dimensions in SI units [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] 1137 1024 1137 1024 1180 1067 1040 1333 1220 1170 1000 1485 1372 1300 1050 1537 1424 1365 1200 1735 1622 1560 1350 1025...
  • Page 69 Proline Promag W 400 [in] [in] [in] [in] [in] [in] [in] [in] 4.41 47.5 43.0 90.5 86.0 58.4 84.4 4.41 51.2 46.8 98.0 93.5 64.2 92.1 4.41 53.2 48.7 101.9 97.5 68.2 102.3 The length is independent of the selected pressure rating. Length in accordance with DVGW/ISO.
  • Page 70: Weight

    Proline Promag W 400 Pressure rating [mm] [in] [mm] [in] [mm] [in] [mm] [in] [mm] [in] ASME, Class 15.5 18.5 21.3 15.6 DIN, PN 6 17.3 20.7 23.0 16.4 DIN, PN 10 17.3 21.1 23.0 16.4 ASME, Class 17.3 21.1 23.0...
  • Page 71 Proline Promag W 400 Weight in SI units Nominal diameter EN (DIN), AS ASME, AWWA [mm] [in] Pressure rating [kg] Pressure rating [kg] Pressure rating [kg] PN 40 Class 150 – PN 40 Class 150 – 1 ½ PN 40...
  • Page 72 Proline Promag W 400 Order code for "Design", option A "Insertion length short" with DN 450 to 2000 (18 to 78") Nominal EN (DIN) ASME, AWWA diameter [mm] [in] Pressure [kg] Pressure [kg] Pressure [kg] Pressure [kg] Pressure [kg] Pressure...
  • Page 73 Proline Promag W 400 Weight in US units Nominal diameter ASME, AWWA [mm] [in] Pressure rating [lbs] Class 150 1 ½ Class 150 Class 150 Class 150 Class 150 Class 150 Class 150 Class 150 Class 150 Class 150 Class 150...
  • Page 74 Proline Promag W 400 Nominal diameter ASME, AWWA [mm] [in] Pressure rating [lbs] 1 200 Class D 1989 – Class D 2809 – Class D 3517 1 650 Class D 4701 1 800 Class D 5665 2 000 Class D 6866 Values with polycarbonate plastic transmitter;...
  • Page 75 Proline Promag W 400 Nominal diameter EN (DIN), AS ASME, AWWA [mm] [in] Pressure rating [kg] Pressure rating [kg] Pressure rating [kg] – PN 16 Class 150 – PN 16 Class 150 PN 10 Class 150 PN 10 Class 150...
  • Page 76 Proline Promag W 400 Nominal EN (DIN) ASME, AWWA diameter [mm] [in] Pressure [kg] Pressure [kg] Pressure [kg] Pressure [kg] Pressure [kg] Pressure [kg] rating rating rating rating rating rating 1 000 PN 6 PN 10 PN 16 Class D...
  • Page 77 Proline Promag W 400 Nominal diameter ASME, AWWA [mm] [in] Pressure rating [lbs] Class 150 Class 150 Class 150 Class 150 Class 150 Class 150 Class 150 Class D – Class D 1010 Class D 1208 Class D 1760 1 000...
  • Page 78: Measuring Tube Specification

    Proline Promag W 400 Order code for "Sensor option", option CA "Corrosion protection" (IP66/67, Type 4X, fully welded; corrosion protection EN ISO 12944 C5-M) with DN 25 to 300 (1 to 12") Nominal diameter ASME, AWWA [mm] [in] Pressure rating...
  • Page 79: Materials

    Proline Promag W 400 Nominal diameter Pressure rating Measuring tube internal diameter EN (DIN) ASME AS 2129 Hard rubber Polyurethane AWWA AS 4087 [mm] [in] [mm] [in] [mm] [in] 1 400 – PN 6 – – – 1 402 55.2 –...
  • Page 80 Proline Promag W 400 Compact and remote versions and sensor connection housing Cable entry/cable gland Material Cable gland M20 × 1.5 Plastic Remote version: cable gland M20 × 1.5 • Sensor connection housing: Nickel-plated brass Option of reinforced connecting cable •...
  • Page 81: Fitted Electrodes

    Proline Promag W 400 Measuring tubes • DN 25 to 300 (1 to 12"): stainless steel 202, 1.4301 (304), 1.4306 (304L); for carbon steel flanges with Al/Zn protective coating • DN 50 to 300 (2 to 12"): stainless steel 202, 1.4301 (304), 1.4306 (304L); for carbon steel flanges with protective varnish (IP68) •...
  • Page 82: Process Connections

    Proline Promag W 400 Optionally available with DN 350 to 2000 (14 to 78"): Exchangeable measuring electrodes made from 1.4435 (304L) Process connections Flange connections: • EN 1092-1 (DIN 2501) – DN ≤ 300 (12"): fixed flange (PN 10/16/25/40) = form A –...
  • Page 83: Local Operation

    Proline Promag W 400 Efficient diagnostics increase measurement availability • Troubleshooting measures can be called up via the device, operating tools and Web browser • Diverse simulation options, logbook for events that occur and optional line recorder functions In custody transfer mode, operation is only possible to a limited extent once the device has been put into circulation or has been lead-sealed.
  • Page 84: Remote Operation

    Proline Promag W 400 Remote operation Via HART protocol A0017124  28 Options for remote operation via HART protocol Control system (e.g. PLC) Field Communicator 475 Computer with operating tool (e.g. FieldCare, AMS Device Manager, SIMATIC PDM) Commubox FXA195 (USB)
  • Page 85: Certificates And Approvals

    Directives. These are listed in the corresponding EC Declaration of Conformity along with the standards applied. Endress+Hauser confirms successful testing of the device by affixing to it the CE mark. C-Tick symbol The measuring system meets the EMC requirements of the "Australian Communications and Media Authority (ACMA)".
  • Page 86: Ordering Information

    The application packages can be ordered from Endress+Hauser either directly with the device or subsequently. Detailed information on the order code in question is available from your local Endress +Hauser sales center or on the product page of the Endress+Hauser website: www.endress.com.
  • Page 87: Diagnostics Functions

    • Extension of calibration intervals. Accessories Various accessories, which can be ordered with the device or subsequently from Endress+Hauser, are available for the device. Detailed information on the order code in question is available from your local Endress+Hauser sales center or on the product page of the Endress+Hauser website: www.endress.com.
  • Page 88: Communication-Specific Accessories

    Service-specific accessories Accessories Description Applicator Software for selecting and sizing Endress+Hauser measuring devices: • Calculation of all the necessary data for identifying the optimum flowmeter: e.g. nominal diameter, pressure loss, accuracy or process connections. • Graphic illustration of the calculation results Administration, documentation and access to all project-related data and parameters over the entire life cycle of a project.
  • Page 89: System Components

    For details, see "Technical Information" TI00133R and Operating Instructions BA00247R Documentation The following document types are available: • On the CD-ROM supplied with the device • In the Download Area of the Endress+Hauser Internet site: www.endress.com → Download Standard documentation Communication Document type Documentation code...
  • Page 90 Proline Promag W 400 Applicator ® , FieldCare ® , Field Xpert , HistoROM ® , Heartbeat Technology Registered or registration-pending trademarks of the Endress+Hauser Group Endress+Hauser...
  • Page 92 www.addresses.endress.com...