Page 2
“DVP-PLC Application Manual: Special Modules”. DVP-10PM is an OPEN TYPE device and therefore should be installed in an enclosure free of airborne dust, humidity, electric shock and vibration. The enclosure should prevent non-maintenance staff from operating the device (e.g.
#1:X0, X2, X4 and X6 can separately be the DOG signal for X, Y, Z and A axes. X1, X3, X5 and X7 can be the PG0 signal for the four axes #2:X10、X11 are MPG pulse inputs. #3:X12、X12 and X13 can only receive differential pulse signals for counting. ...
L and N terminals. Wiring AC110V or AC220V to the +24V terminal or input terminal will result in serious damages on the PLC. 2. The AC power input for DVP-10PM and I/O modules should be ON or OFF at the same time.
Page 6
[ Figure 7 ] Wiring of Differential Inputs X10 to X13 on DVP-10PM are 5 to 24 VDC high-speed input circuits; other inputs are 24 VDC). The frequency of high-speed input circuits can be up to 200 kHz and is for connecting to differential (double-wire) LINE DRIVER output circuits.
Page 7
PLC internal program, to ensure safe protection in case of any unexpected errors. Wiring of Differential Outputs Differential output with ASDA-A & A+, ASDA-A2 series servo drives DVP-10PM diff er ential output Dr iver Y10+ /P LS...
BAT.LOW Indicator BAT.LOW indicator will be on when the battery is in low voltage. When this happens, change the battery as soon as possible in case your program and data saved in the latched area will be lost. After the power is switched off, the data in the latched area will be stored in the SRAM memory, and its power will be supplied by the battery.