Appendix A
Maintenance Log Sheets
Level E Maintenance - 600,000 Pages (Service)
Action
Replace
Main charger
Replace
Cleaning unit
See Note 1
Replace
Smoke filter
Replace
Transporting belt-3
Note 1: When the cleaning unit has been vacuumed every 150,000 pages and has
been used under nominal operating conditions, it must be replaced at 600,000 pages.
However, it may need to be replaced more frequently if used for high-density printing
or printing on uneven media, or if used under severe operating conditions.
198
Item
Part #
705741-001
705740-001
703540-001
703531-035
Performed By
Date