Download Print this page

Kenwood KDC-MP638U Service Manual page 8

Hide thumbs Also See for KDC-MP638U:

Advertisement

KDC-MP638U/W7041U
/W7141UY/X692/X7009U
MICROCOMPUTER'S TERMINAL DESCRIPTION
Pin No.
Pin Name
64
MUTE_2
65
LINE_MUTE
66
NC (SA_IN)
67
NC (SA_RST)
68
NC (SA_CLK)
69
NC (MUTE_SA)
70
PWIC_DC_DET
71
ACC_DET
72
BU_DET
73
LX_REQ_S
74
MUTE_AFS
74
NC
75
SDA/EVOL_SDA
75
SDA/E2P_SDA
76
SCL/EVOL_SCL
76
SCL/E2P_SCL
77
PWIC_MUTE
78
PWIC_STBY
79
LX_REQ_M
80
LX_MUTE
81
LX_CON
82
LX_RST
83
MUTE_PRE_FR
84
MUTE_PRE_SW
85
PON_AM
86
TUN_IFC_OUT
87
TUN_SMETER
88
RDS_NOISE
88
NC
89
RDS_AFS_M
89
NC
90
TYPE_1
91
TYPE_2
92
G_Y_OUT
92
NC
8
I/O
Application
O
IC-2 SW MUTE control
I
Line mute detection
O
Not used
O
Not used
O
Not used
O
Not used
I
DC offset detection terminal
I
ACC detection
I
BU detection
I
Communication request from slave unit
IC-2 MUTE_C control
I/O
AFS MUTE
I
Not used (For other type than E-TYPE)
I/O System μ-com → IC-2 data output
I/O I2C data for ROM correction
I/O System μ-com → IC-2 CLK output
I/O I2C clock for ROM correction
O
Power IC MUTE terminal
O
Power IC standby terminal
O
Communication request to slave unit
I
MUTE request from slave unit
O
Start-up request to slave unit
O
Hardware-reset to slave unit
O
External PREOUT_MUTE F/R
External PREOUT_MUTE SUB
O
MUTE_2 shock noise measure
I/O AM+B power supply control terminal
I
F/E IFC OUT input terminal
I
S meter voltage detection terminal
I
FM noise voltage detection terminal
O
Not used. (In models without RDS)
I/O Time constant switching when noise is detected
O
Not used. (In models without RDS)
I
A/D 5 pattern
I
A/D 5 pattern
I
Detection of Y direction movement of G analyzer
O
Not used. (In models without G antenna)
Truth
Processing / Operation / Description
Value Table
L: Mute ON, Independent setup of time
constant 10ms, H: In normal condition
Shall be used together with MUTE_PRE_SW
IC2 shock noise measure
TEL MUTE: 1V or less, NAVI MUTE: 2.5V or higher
Output L fi xed
Output L fi xed
Output L fi xed
Output L fi xed
L: ACC found, H: ACC not found
L: BU found, H: When No BU
Reduction of power, and Over voltage
L: Mute ON, Independent setup of time
constant 0.5ms, Hi-Z: While in normal
Input Hi-Z fi xed
Communication speed 200-400k
Communication speed 200-400k
Communication speed 200-400k
Communication speed 200-400k
L: While STANDBY source, momentary power
down, L: While TEL MUTE
POWER ON: H, POWER OFF: L
H: Mute ON, L: Mute OFF
H: Slave unit ON, L: Slave unit OFF
H: RST, L: Normal
"L" when Obit, or momentary power down
"L" when Obit, or momentary power down
Shall be used in addition to MUTE_2.
H: ON when AM is being received.
Hi-z: OFF in other condition.
H: Station is found., L: No station is found.
Output L fi xed
e
L: During AF search, Hi-Z: In normal condition
Output L fi xed
q
q
Output L fi xed

Advertisement

loading

This manual is also suitable for: