Haier GE Connect Series Service Manual page 78

Split heat pumps
Table of Contents

Advertisement

Maintenance
Model: AUH4860ZGDA
Note: Be sure power is isolated and refrigerant is recovered before removing the gas liquid separator.
Step
1. Loosen the wire clamp at the
bottom of the electric box and
the screws of electric box.
2. Remove the electric box.
3. Remove the compressor/
gas liquid separator from the
chassis.
76
Compressor/Gas Liquid Separator Removal
Picture
CONNECT SERIES SERVICE MANUAL
Work instruction
Remove the upper, lower and front
panels.
Loosen the wire clamp at the bottom
of the electric box.
Unscrew the screws of electric box.
The connection wires inside and
outside the electric box should be
removed.
When removing the electric box, be
careful to protect the components.
Remove the compressor/gas liquid
separator and replace with a new
one.
Note: When replacing the
compressor/gas liquid separator,
avoid touching the nearby pipeline
and components.