Outdoor Unit:
Model: AUH2436ZGDA, AUH4860ZGDA
Main Board
No.
Printing
1
AC-L
Live wire input
2
AC-N
Neutral wire input
3
HEAT_TIE_B
Chassis electric heating belt
4
HEAT_TIE_C
Compressor electric heating belt
5
4WAY
4-way valve
6
VA
Electromagnetic valve interface
7
FA
Electronic expansion valve interface
Electronic expansion valve 1 interface
8
FA1
Refrigerant heat dissipation
9
COMM1
Drive communication interface
10
L-PRESS
Low pressure sensor interface
Interface
No.
11
12
13
14
15
16
17
18
19
20
CONNECT SERIES SERVICE MANUAL
Printing
H-PRESS
High pressure sensor interface
LPP
System low pressure protection interface
HPP
System high pressure protection interface
2. Outdoor tube temperature sensor interface
4. Outdoor ambient temperature sensor
T_SENSOR2
interface
6. Discharge temperature sensor interface
T_LAC
Low temperature cooling temperature sensing
COM7
Unit communication interface
CN6
GPRS communication interface
COM-MANUAL
Thermostat interface
DC_MOTOR1
DC motor output
DC_MOTOR2
PWR1
310V DC power supply interface